1
.
| 1 | 1 | Agarose gel electrophoresis apparatus with power supply pack | Suitable for serum protein separation | Rate per piece |
|
2
.
| 2 | 2 | Air sampler system | • Rechargeable battery operated• Microprocessor controlled electric fan• Low battery control and alarm• Delay start• System should facilitate the use of plates of different sizes 90mm, 65mm, 75mm, etc• Total volume of sampled air programmable from 1 to 1000 liters, with 1 liter step• Preset sampling flow rate 30-60-90-120 liters• Manual sampling (for air volume >1000lit)• Sequential sampling available• The system should be supplied with at least 5 sampling grids which can be used alternatively for sampling. Also the above grids should be autoclavable for further repeated use• Instruction manual should be provided• The system should have the memory which can store at least four sampling volumes in it and which can be edited and modified as and when required.• An LCD screen should be present to program the instrument and follow its operation.• Calibration, validation and warranty certificated should be provided• Company should provide Good manufacturing product (GMP)/ WHO certificate & ISO certificate/FDA approved along with tender. • Should have ISI mark.• Should have good consumer base in Gujarat.• Permanent service engineer should be posted in Gujarat and attend to complaints and rectify them within 48 hours.• Comprehensive and full training of all users by suppliers for operating the equipment.• For imported item, CE certificate is must. -Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
3
.
| 3 | 3 | Autoclave - vertical, fully automatic | • size Medium• The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs.• Should works on 3-phase, 440V, A/C, 50HZ supply.• Application specific integrated chip Microprocessor controller.• Provided with RS 232 output • Fitted with pressure control switch • Fitted with low water level cut off device.• The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel.• Supplied with pedal lifting device.• The unit has been fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve.• The steam generator is made out of stainless steel heavy gauge and water draining valve.• Inner drum size : 450 x 600 mm• Accessories : Timer, 2 lid sealed gasket, Autoclave indicator strip, 2 heating coils.• Company should provide Good manufacturing product (GMP)/ WHO certificate & ISO certificate/FDA approved along with tender. • Should have ISI mark. • Should have good consumer base in Gujarat.• It is preferable, if equipment is approved by any apex Govt. institute in India.• It is preferable, if equipment have good rapport in commercial market since last 3 year.• Permanent service engineer should be posted in Gujarat and attend to complaints and rectify them within 48 hours.• Comprehensive and full training of all users by suppliers for operating the equipment.• The company should supply the list of institution where the equipments are being used.• Authority letter from Manufacturer is mandatory.• For imported item, CE certificate is must.-Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
4
.
| 4 | 4 | Autoclave - vertical, fully automatic | • size small• The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs.• Should works on 3-phase, 440V, A/C, 50HZ supply.• Application specific integrated chip Microprocessor controller.• Provided with RS 232 output • Fitted with pressure control switch • Fitted with low water level cut off device. • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel.• Supplied with pedal lifting device.• The unit has been fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve.• The steam generator is made out of stainless steel heavy gauge and water draining valve. • Inner drum size : 550 x 750 mm• Accessories : Timer, 2 lid sealed gasket, Autoclave indicator strip, 2 heating coils.• Company should provide Good manufacturing product (GMP)/ WHO certificate & ISO certificate/FDA approved along with tender. • Should have ISI mark. • Should have good consumer base in Gujarat.• It is preferable, if equipment is approved by any apex Govt. institute in India.• Permanent service engineer should be posted in Gujarat and attend to complaints and rectify them within 48 hours.• Comprehensive and full training of all users by suppliers for operating the equipment.• Authority letter from Manufacturer is mandatory.• For imported item, CE certificate is must. - Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
5
.
| 5 | 5 | Autoclave Double drum vertical (Non Microprocessor) | • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs.• Should works on 3-phase, 440V, A/C, 50HZ supply.• Fitted with pressure control switch • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel.• Supplied with pedal lifting device.• The unit should be fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve.• Inner drum size : 350 x 550 mm• Accessories : 2 gasket, 2 heating coils. - Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
6
.
| 6 | 6 | Autoclave Double drum vertical (Non Microprocessor) | • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs.• Should works on 3-phase, 440V, A/C, 50HZ supply.• Fitted with pressure control switch • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel.• Supplied with pedal lifting device.• The unit should be fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve.• Inner drum size : 550 x 750 mm• Accessories : 2 gasket, 2 heating coils.-Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
7
.
| 7 | 7 | Autoclave Double drum vertical (Non Microprocessor) | • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs.• Should works on 3-phase, 440V, A/C, 50HZ supply.• Fitted with pressure control switch • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel.• Supplied with pedal lifting device.• The unit should be fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve.• Inner drum size : 450 x 600 mm• Accessories : 2 gasket, 2 heating coils.-Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
8
.
| 8 | 8 | Autoclave Double drum vertical (Non Microprocessor) | • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs.• Should works on 3-phase, 440V, A/C, 50HZ supply.• Fitted with pressure control switch • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel.• Supplied with pedal lifting device.• The unit should be fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve.• Inner drum size : 400 x 600 mm• Accessories : 2 gasket, 2 heating coils.-Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
9
.
| 9 | 9 | Automated nucleic acid extraction system | • Automated Bench top nucleic acid and proteins extraction and purification device using proven technology like silica based spin column or magnetic bead separation technology. • It should have touch panel and compatible with wide range of samples such as blood, plasma, body fluids, bacteria, and FFPE (Formalin Fixed Paraffin Embeded) tissue etc.• It should be automatic and the unit should be capable to process minimum 10 samples per run.• The system should be integrated with touch-screen/ computer, should allow the user to select and run protocols, install or delete protocols, save data files.• A comprehensive load check should be performed prior to sample processing to check worktable setup and to help to ensure correct loading of the instrument. • There should be optical sensor to checks the type of filter tips loaded on the worktable and that there are sufficient tips for the protocol run.• There should be availability of compatible kits for DNA extraction/RNA extraction/DNA and RNA extraction simultaneously (Nucleic acid extraction)/Protein/ miRNA from the clinical sample.• The system should be programmable to enable modifications and customization of the protocols according to the user needs and applications and should provide future upgradation in software free of charge.• Operating temperature 18–28ºC (Room temperature).• Suitable UPS with maintenance free batteries for 1 hour backup should be supplied with the system.• CE marked/FDA approved/ISO marked. -Company should provide 3 years compulsory warranty. -Company should provide CMC rates for 05 years after completion of warranty. -For L-1, CMC rates will be considered along with quoted price of equipment. | Rate per piece |
|
10
.
| 10 | 10 | BacT Alert Reflectance stanadards | BacT AlertT reflectance standard of Biomeriux compatible to BacT/AlerT 3D 60 & 120. It should contain Reflectance Standard A & B | Rate per piece |
|
11
.
| 11 | 11 | Battery for UPS | 26 AH, 12 Volts | Rate per piece |
|
12
.
| 12 | 12 | Battery for UPS | 18 AH, 12 Volts | Rate per piece |
|
13
.
| 13 | 13 | Bio safety cabinet Class II | • Class II, Type-A • Working Size 2†|