| 1 | 1 | Providing & lowering in tubewell ISI marked GI Pipe \"B\" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3 mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | nominal bore of 50 mm | BI01010001010000000000000515BI0100001113 | 100 | per meter |
|---|
| 3 | 1.02 | nominal bore of 65 mm | BI01010001010000000000000515BI0100001114 | 100 | per meter |
|---|
| 4 | 2 | Supply & fixing of ISI marked three core PVC flat submersible cable as per IS 694 : 1990 or amended up to date and conductor as per class 5 of IS 8130 : 1980 including making connecting etc | BI01010001010000000000000515BI0100001115 | | |
|---|
| 5 | 2.01 | 4 Sqmm | BI01010001010000000000000515BI0100001116 | 100 | per meter |
|---|
| 6 | 2.02 | 6 Sqmm | BI01010001010000000000000515BI0100001117 | 100 | per meter |
|---|
| 7 | 2.03 | 10 Sqmm | BI01010001010000000000000515BI0100001118 | 100 | per meter |
|---|
| 8 | 2.04 | 16 Sq mm | BI01010001010000000000000515BI0100001119 | 100 | per meter |
|---|
| 9 | 3 | Supply & Installation of 3 phase ISi marked submersible motor pump set of five star rating by BEE and as per JS: 8034-2011 (pump) and IS 9283-2013 (motor) or amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. | BI01010001010000000000000515BI0100001120 | | |
|---|
| 10 | 3.01 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. | BI01010001010000000000000515BI0100001121 | 5.5 | KW |
|---|
| 11 | 3.02 | Up to 5.5 KW (7.5 HP) & head above 120 mtr | BI01010001010000000000000515BI0100001122 | 5.5 | KW |
|---|
| 12 | 3.03 | 7.5 KW (1O HP) & head up to 120 mtr. | BI01010001010000000000000515BI0100001123 | 7.5 | KW |
|---|
| 13 | 3.04 | 7.5 KW (10 HP) & head above 120 mtr. | BI01010001010000000000000515BI0100001124 | 7.5 | KW |
|---|
| 14 | 3.05 | 9.3 KW (12.5 HP) & head up to 120 mtr | BI01010001010000000000000515BI0100001125 | 9.3 | KW |
|---|
| 15 | 3.06 | 9.3 KW (12.5 HP) & head above 120 mt | BI01010001010000000000000515BI0100001126 | 9.3 | KW |
|---|
| 16 | 3.07 | 11 KW (15 HP) & head up to 120 mtr. | BI01010001010000000000000515BI0100001127 | 11 | KW |
|---|
| 17 | 3.08 | 11 KW (IS HP) & head above 120 mtr | BI01010001010000000000000515BI0100001128 | 11 | KW |
|---|
| 18 | 3.09 | 13 KW (17.5 HP) & head up to 120 rntr. | BI01010001010000000000000515BI0100001129 | 13 | KW |
|---|
| 19 | 3.1 | 13 KW (17.5 HP) & head above 120 mtr | BI01010001010000000000000515BI0100001130 | 13 | KW |
|---|
| 20 | 3.11 | 15 KW (20 HP) and above, head up to 120 mtr | BI01010001010000000000000515BI0100001131 | 15 | KW |
|---|
| 21 | 3.12 | 15 KW (20 HP) and above, head above 120 mtr. | BI01010001010000000000000515BI0100001132 | 15 | KW |
|---|
| 22 | 4 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg's length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. | BI01010001010000000000000515BI0100001133 | | |
|---|
| 23 | 4.01 | Up to 5 HP | BI01010001010000000000000515BI0100001134 | 1 | Nos |
|---|
| 24 | 4.02 | Above 5 HP and up to 10 HP | BI01010001010000000000000515BI0100001135 | 1 | Nos |
|---|
| 25 | 4.03 | Above 10 HP and up to 15 HP | BI01010001010000000000000515BI0100001136 | 1 | Nos |
|---|
| 26 | 4.04 | Above 15 HP | BI01010001010000000000000515BI0100001137 | 1 | Nos |
|---|
| 27 | 5 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & Smm thick I OOmm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both end in 80mm sizes passing through a hole in the centre of MS sheet. A 25mm socket with end plug shall also be welded over top plate (as per drawillg enclosed). A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall tie provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. | BI01010001010000000000000515BI0100001138 | | |
|---|
| 28 | 5.01 | 200 mm dia | BI01010001010000000000000515BI0100001139 | 1 | Each |
|---|
| 29 | 5.02 | 250 mm dia | BI01010001010000000000000515BI0100001140 | 1 | Each |
|---|
| 30 | 6 | Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 406411 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia | BI01010001010000000000000515BI0100001141 | | |
|---|
| 31 | 6.01 | 50 mm dia | BI01010001010000000000000515BI0100001142 | 1 | Each |
|---|
| 32 | 6.02 | 65 mm dia | BI01010001010000000000000515BI0100001143 | 1 | Each |
|---|
| 33 | 6.03 | 80 mm dia | BI01010001010000000000000515BI0100001144 | 1 | Each |
|---|
| 34 | 7 | Providing & Fixing pump safety cage as per specifications or as directed by engineer incharge | BI01010001010000000000000515BI0100001145 | 1 | Each |
|---|
| 35 | 8 | Providing & Fixing of double flanged, Cl body, ISi marked NR V of approved make of following sizes | BI01010001010000000000000515BI0100001146 | | |
|---|
| 36 | 8.01 | 65 mm dia | BI01010001010000000000000515BI0100001147 | 1 | Each |
|---|
| 37 | 8.02 | 80 mm dia | BI01010001010000000000000515BI0100001148 | 1 | Each |
|---|
| 38 | 9 | Providing supplying fixing ISI CI sluice valve including all taxes etc | BI01010001010000000000000515BI0100001149 | | |
|---|
| 39 | 9.01 | 50 MM | BI01010001010000000000000515BI0100001150 | 1 | Nos |
|---|
| 40 | 9.02 | 65 MM | BI01010001010000000000000515BI0100001151 | 1 | Nos |
|---|
| 41 | 9.03 | 80 MM | BI01010001010000000000000515BI0100001152 | 1 | Nos |
|---|
| 42 | 9.04 | 100 MM | BI01010001010000000000000515BI0100001153 | 1 | Nos |
|---|
| 43 | 9.05 | 125 MM | BI01010001010000000000000515BI0100001154 | 1 | Nos |
|---|
| 44 | 9.06 | 150 MM | BI01010001010000000000000515BI0100001155 | 1 | Nos |
|---|
| 45 | 9.07 | 200 MM | BI01010001010000000000000515BI0100001156 | 1 | Nos |
|---|
| 46 | 9.08 | 250 MM | BI01010001010000000000000515BI0100001157 | 1 | Nos |
|---|
| 47 | 9.09 | 300 MM | BI01010001010000000000000515BI0100001158 | 1 | Nos |
|---|
| 48 | 9.1 | 350 MM | BI01010001010000000000000515BI0100001159 | 1 | Nos |
|---|
| 49 | 9.11 | 400 MM | BI01010001010000000000000515BI0100001160 | 1 | Nos |
|---|
| 50 | 10 | Providing supplying , Lowering & laying in standard lengths HDPE PE -80 PN-6 Pipes conforming to IS-4984: 1995 with necessary jointing material like mechanical connectors, i.e thread/ insert joint/ oquick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion welding method,including all taxes [ Central and local ], transportation and freight charges,inspection charges, loading/ unloading charges, stacking the same in closed shade duly protecting from sunrays and rains, including cost of labour and material, specials [ Tee, bend etc.] satisfactory, hydraulic testing etc. complate as per tachnical specifications and direction of engineer-in- charge. [excluding earth work] supply up to 90 mm dia. coil & above 90 mm dia straight leanth in 6 m.] NOTE : Providing and fixing of al requisite specials as per drawing, design and layout are inclusive in RM messurement of the item and shall not be paid separatelyin following nominal diameter. | BI01010001010000000000000515BI0100001161 | | |
|---|
| 51 | 10.01 | 90 mm dia | BI01010001010000000000000515BI0100001162 | 100 | per meter |
|---|
| 52 | 10.02 | 110 mm dia | BI01010001010000000000000515BI0100001163 | 100 | per meter |
|---|
| 53 | 11 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter in All kinds of soils. | BI01010001010000000000000515BI0100001164 | 100 | CUM |
|---|