| 1 | 1 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth: for foundation, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/disintegrated rock. | | 19 | Cum |
|---|
| 2 | 2 | M/L for PCC 1:2:4 type B-2 with using 40mm graded aggregate as in foundation filling and mass concrete. | | 14 | Cum |
|---|
| 3 | 3 | M & L Cement concrete in foundations, filling and mass-concrete type C2 1:3:6 (40 mm graded aggregate) \n | | 0.88 | Cum |
|---|
| 4 | 4 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm as soft/disintegrated rock complete all as specified and directed. | | 17.3 | Cum |
|---|
| 5 | 5 | Removing excavated material exc 250 m but n exc.500 m and depositing where directed at a level n exc 1.5m above the starting point as in rock complete. | | 8.7 | Cum |
|---|
| 6 | 6 | M&L for walling of porbandar stone squared rubble, brought up to course, well bonded, bedded and solidly hearted, built in CM (1:4). | | 2.5 | Cum |
|---|
| 7 | 7 | M&L rendering 10 mm thick on fair faces of stone masonary or brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement) | | 6 | Sqm |
|---|
| 8 | 8 | M&L for two coats of weather proof anti fungal Acrylic Exterior Emulsion paint on new plaster surfaces over a priming coat of same Emulsion all as specified. | | 6 | Sqm |
|---|
| 9 | 9 | M&L Hardcore of broken stone of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface | | 3.85 | Cum |
|---|
| 10 | 10 | M&L 100 mm thick cement concrete type E2 1:3:6 (40 mm graded stone aggregate) in sub base of flooring. | | 38.5 | Sqm |
|---|
| 11 | 11 | M & L for machine cut kota stone slab flooring 20 - 25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with C M 1:6 | | 38.5 | Sq m |
|---|
| 12 | 12 | M & L for machine cut kota stone slab 18 - 20 mm thick in skirting, riser etc over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including screed bed or bedding layer of mortar 10 mm thick for laying floor finishes with C M 1:4 | | 3 | Sq m |
|---|
| 13 | 13 | M & L for machine cut mirror polished kota stone slab flooring 20 - 25mm thick in single piece for tread of steps including two nos friction grove and rounded edge over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with C M 1:6 | | 2 | Sq m |
|---|
| 14 | 14 | M & L plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in kerb including weathering, slightly rounded or chamfered etc, complete all as specified. | | 0.4 | Cum |
|---|
| 15 | 15 | S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to I.S.1161-1998 grade St-240. | | 2240 | Kg |
|---|
| 16 | 16 | S&F for Roof trusses (Framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing(Beam, tee, angle, channel or flat section) including distance pieces, cleats, etc. Gde Fe 410-W (Gde-E-250) quality-A. | | 3700 | Kg |
|---|
| 17 | 17 | S&F for Plate (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment Gde Fe- 410-w (Gde-E-250) quality-A. | | 570 | Kg |
|---|
| 18 | 18 | S&F Mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or diameter of neck 16 to 20mm square nut bolt exc 5 cm but n exc 10 cm long. | | 25 | Kg |
|---|
| 19 | 19 | M&L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer. | | 190 | Sq m |
|---|
| 20 | 20 | High tensile galvalume sheets colour coated single skin high rib / multi rib TMP Profile Galvalume sheeting having 1000-1020 mm width 28 mm high crest @ maximum 250 mm pitch (centre to center) and minimum 190mm manufactured out of 0.50 mm TCT (total coated thickness) cold rolled steel, having yield strength 550MPa minimum and wall coated with 25 micron modified polyster paint system applied on Zincalume on top and with back coating on sheet shall be 7-10 micron epoxy paint. The sheet shall be supplied in length maximum upto 6-12 meters long to suit with structural dimensions and fixed with self tapping screws with built in gasket (with bitumen washer) of suitable size machine fixed as per manufacturer instructions and applying adhesive compound to joint overlap of sheets complete all as specified and directed by Engineer-in-Charge. | | 250 | Sqm |
|---|
| 21 | 21 | Pre-painted galvalume aluminum zinc coating GI based steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in flashings made to shape of plain sheet (junction) of wall cladding and lower roof on annexe, fixed with self tapping screws complete all as specified & directed by Engineer-in-Charge. | | 11.5 | Sqm |
|---|
| 22 | 22 | S&F 4mm thick ACP panel cladding, fixing on vertical or horizontal MS frame work and filling silicon gel for grove including fixing of Screw complete all as specified and directed. | | 14 | Sqm |
|---|
| 23 | 23 | S&F for Stainless steel letters or figures (block, roman, Italic or Indian) made of SS grade 304 height of letters not kess than 250 mm and width not less than 200 mm each letter complete all as specified and directed by Engineer-in-Charge. | | 22 | Each |
|---|
| 24 | 24 | Excavating in post holes (or similar holes) each in hard/dense soil n.exc 0.5 cum getting out hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface. | | 253 | Each |
|---|
| 25 | 25 | M & L for Providing precast reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 and n exc 250 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed | | 22 | Cum |
|---|
| 26 | 26 | M & L for plain cement concrete type D2 (1:4:8) (use 40mm graded aggregate) in foundations, filling and mass concrete. | | 119 | Cum |
|---|
| 27 | 27 | S & F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured). | | 142 | 100 RM |
|---|
| 28 | 28 | S&F Framed work for portion framed and hung as gates, including pintle hinges, stops, hand made sliding bolts etc .such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guards bars; barred iron doors; ladders; framed balusters; walk ways; railways; railing; framework of water tanks and similar work including necessary welding conforming to Fe 290, Gde E- 165 | | 700 | Kg |
|---|
| 29 | 29 | M&L for reinforced cement concrete 1:1 1/2:3 type A1 (20mm graded stone agg) (Nominal mix) as in foundation, incl. rafts,footings,foundation beam plinth beams, bases for columns etc. basement slabs,under rammed piles and mass concrete . | | 1.2 | Cum |
|---|
| 30 | 30 | M&L for reinforced cement concrete 1:1 1/2:3 type A1 (20mm graded stone aggt) (nominal mix) as in columns,pillars piers,posts and struts . | | 2.3 | Cum |
|---|
| 31 | 31 | S & F CRS steel deformed or twisted bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips. | | 2700 | Kg |
|---|
| 32 | 32 | M&L CRS bars 6 to 8 mm dia and over cut to length, bent to shape required incl cranking, bending, spirally for hooping for column hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. confirming to Fe-410-S or Fe-410-0. | | 1400 | Kg |
|---|
| 33 | 33 | M&L for form work to sides of concrete foundation, footings, base of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams and similar work, vertical or batter. | | 4 | Sqm |
|---|
| 34 | 34 | Formwork to sides of pillars,posts, struts, piers, columns and stanchions for rough finish flat surface of concrete columns circular on plan. | | 15 | Sqm |
|---|
| 35 | 35 | M & L for rendering 10mm thick on fair faces of brick work or concrete surfaces as in CM 1:4 to be finished even and smooth (without using extra cement). | | 13 | Sqm |
|---|
| 36 | 36 | M&L for preparation of new plastered surface of wall and applying two coat of cement base paint white or tinted. | | 13 | Sqm |
|---|
| 37 | 37 | M&L for three coat of white washing on new undecorated plastered surface including preparation of surface on walls complete all as specified. | | 440 | Sqm |
|---|
| 38 | 38 | Excavating over areas, n exc 1.5 m deep and getting out in soft/disintegrated rock. | | 7 | Cum |
|---|
| 39 | 39 | M & L for point wiring for one light /fan point with 1.5 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FRLS cable controlled by one way switch, drawn with PVC conduit with all accessorie and PVC Box of suitable size including 1.5 sqmm multi strand copper conductor cable (green colour) PVC insulated and unsheathed for earth continuity connected to common earth dolly for mounting of fittings such as switch, socket all as specified and directed. | | 2 | Per point |
|---|
| 40 | 40 | All as per item No39 above but for 5 amps socket outlet on same board board. | | 1 | Per point |
|---|
| 41 | 41 | All as per item No39 but One 3 pin socket outlet, 5 Amps,independent borad complete all as specified andas directed. | | 2 | Per point |
|---|
| 42 | 42 | All as per item No39 but One 3 pin socket outlet with 2.5 sqmm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed. | | 2 | Per point |
|---|
| 43 | 43 | Supply and fixing of ceiling rose surface backelite 65x50 mm having 3 terminal complete all as specified and directed.. | | 2 | Each |
|---|
| 44 | 44 | Supply and fixing of Modular white cover plate with frame 3 modules complete all as specified and directed.Make : Havells/HPL/Anchor | | 2 | Each |
|---|
| 45 | 45 | Supply and fixing of white cover plate with frame 12 modules Combined Plate - Coral complete all as specified and directed.Make : Havells/HPL/Anchor | | 5 | Each |
|---|
| 46 | 46 | Supply and fixing of for Modular switch 1 way 6 Amps, 1 modules 230 volts complete all as specified and directed.Make Havells/Roma/Anchor | | 11 | Each |
|---|
| 47 | 47 | Supply and fixing of for Modular switch 1 way 16 Amps, 1 modules 230 volts Complete all as specified and directed. Make : Havells/Roma/Anchor | | 2 | Each |
|---|
| 48 | 48 | Supply and fixing of Modular socket 6A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed. Make : Havells/Roma/Anchor | | 3 | Each |
|---|
| 49 | 49 | Supply and fixing of Modular socket 6A/16A, 2/3 pin combined, 2 modules 230 volts complee all as specified and directed. Make : Havells/Roma/Anchor | | 2 | Each |
|---|
| 50 | 50 | Supply and fixing of Surface/wall Mounting Plastic boxes 3 Modules complete all as specified and as directed.Make:- Havells Cat No :- AHNXMIZX03 or its equivalent of Anchor/HPL | | 2 | Each |
|---|
| 51 | 51 | Supply and fixing of Surface/wall Mounting Plastic boxes 12 Modules complete all as specified and as directed.Make:- Havells Cat No :- AHNXMIZX12 or its equivalent of Anchor/HPL | | 2 | Each |
|---|
| 52 | 52 | Supply and fixing of modular Fan regulator step type, 120W - 2 module complete all as specifoed and as directed Make :- Anchor/Roma/Havells/ MAKE SPECIFIED | | 6 | Each |
|---|
| 53 | 53 | Supply & fix ceiling fans, white in colour complete with canopy, fan rod (with rubber bush and MS Nut Bolts, Pin) of appropriate size according to the site requirement and other necessary accessories required for smooth functioning/fixing of ceiling fan 230 V,1200 mm sweep. BEE 5 star rated as specified and directed by Engineer - in - Charge.\nMake: Havells/Bajaj/Crompton. | | 6 | Each |
|---|
| 54 | 54 | Supply and fixing of JETA IRLS Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium iP66 flood light 120 W, suitable with hanging arrangement for shade complete all as specified and as directed. Make- Havells, Cat No- JETAIRISFLS120WLED757PASYMLTG or its equivalent of Bajaj/C&S/ Make specified | | 2 | Each |
|---|
| 55 | 55 | Supply and Repair/Replacement of surface and wall mounted LED batten,extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver 20 Watt, LED tube light fitting, retrofit T8, complete with powder coated CRCA decorative patti white colour, duly prewired and connecting complete all as specified and directed by Engineer - in - Charge. Make:-Havells Cat no:- ENDURALINERNEOOBS20WLED865SPCWH or its equivalent of Bajaj/C&S /Make specified | | 2 | Each |
|---|
| 56 | 56 | Supply and fixing of stage light Big Deeper LP 601H high brightness 3W X 60 RGBW (1 in 1) Led par light with 4 wires ( 2 power cable + 2 DMX cables) (Ball dia meter 23 Cm) hanging on cover shed with suitable nut,bolds,clamps complete all as specified and as directed | | 2 | Each |
|---|
| 57 | 57 | Supply and fixing of MCB DB Single pole and neutral 4 way double door with 200 amps rated bus bar complete. | | 2 | Each |
|---|
| 58 | 58 | Supply and fixing of MCB SP 6-32 Amps,10 KA breaking capacity 'C' Curve suitable 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge. | | 4 | Each |
|---|
| 59 | 59 | Supply and fixing of MCB SPN-40 Amps,10 KA breaking capacity 'C' Curve suitable 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge. | | 2 | Each |
|---|
| 60 | 60 | M&L of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised earth lead wire 4.0mm dia by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I all as specified and directed. | | 2 | Each Job |
|---|
| 61 | 61 | Supply and fixing of laying/jointing GI Pipe light grade 20mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and finishing PCC after boring/cutting of road/Foot path if any complete all as specified and directed. | | 20 | RM |
|---|
| 62 | 62 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and as directed. | | 20 | RM |
|---|
| 63 | 63 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 sq mm 3 core complete all as specified and as directed. | | 40 | RM |
|---|