| 1 | 1 | Electrical Items : | | | |
|---|
| 2 | 1.1 | PC05 Plus Medium Board for Kirloskar make Chiller unit of model no.-KWF 160.14 , Kirloskar Part No.56.137.50.202. The controller shall be fully programmed and ready to use for our application of Chiller Units at AFCP, NFL Panipat, Model No.KWF 160.14 | item1 | 1 | No. |
|---|
| 3 | 2 | PGD Display 120X32 for Kirloskar make Chiller unit of model no.- KWF160.14 , Kirloskar Part No. 56.137.50.152 | item2 | 2 | No. |
|---|
| 4 | 3 | Optical Oil Level Switch (F-4 O/S) for Kirloskar make Chiller unit of model no.- KWF 160.14 , Kirloskar Part No. 55.400.16.002 | item3 | 1 | No. |
|---|
| 5 | 4 | OIL FILTER WITH O-RING FOR CHILLER UNIT, CAP 160.14,HVAC SYSTM, AFC PLANT. PART NO 55.400.25.401 | item4 | 2 | No. |
|---|
| 6 | 5 | GASKET AND O-RING KIT FOR OIL FILTER FOR CHILLER UNIT, CAP160.14,HVAC SYSTEM AFC PLANT. PART NO.11.000.00.988 | item5 | 2 | No. |
|---|
| 7 | 6 | OIL SEPARATOR HEATER 250W, 230VAC,FOR OIL FILTER FOR CHILLER UNIT, CAP 160.14,HVAC SYSTEM AFC PLANT. PART NO 55.400.58.250 | item6 | 3 | No. |
|---|
| 8 | 7 | PRES.SENSOR SPKT005310 FOR OIL FILTER FOR CHILLER UNIT, CAP 160.14,HVAC SYSTEM AFC PLANT. PART NO 56.103.50.013 | item7 | 3 | No. |
|---|
| 9 | 8 | PRES. SENSOR CABLE SPKC005310 FOR OIL FILTER FOR CHILLER UNIT, CAP 160.14, HVAC SYSTEM AFC PLANT.PART NO 56.103.50.014 | item8 | 3 | No. |
|---|
| 10 | 9 | ELECTRONIC EXPANSION VALVE E6V FOR OIL FILTER FOR CHILLER UNIT, CAP 160.14,HVAC SYSTEM AFC PLANT. PART \n NO 55.400.17.E06 | item9 | 1 | No. |
|---|
| 11 | 10 | VALVE SOLENOID CAPACITY CONTROL FOR OIL FILTER FOR CHILLER UNIT, CAP 160.14,HVAC SYSTEM AFC PLANT PART NO 55.400.16.320 | item10 | 2 | No. |
|---|
| 12 | 11 | VALVE SOLENOID, SIZE 5/8 INCH, ODS 220V FOR OIL FILTER FOR CHILLER UNIT, CAP 160.14,HVAC SYSTEM AFC PLANT. PART NO 55.400.16.203 | item11 | 2 | No. |
|---|
| 13 | 12 | VALVE SOLENOID,SIZE 1/2 INCH ODS 230V FOR OIL FILTER FOR CHILLER UNIT, CAP 160.14, HVAC SYSTEM AFC PLANT. PART NO 55.400.16.805 | item12 | 2 | No. |
|---|
| 14 | 13 | SAFETY RELIEF VALVE OF CHILLER UNIT, SIZE 18MM, CAPACITY-16BAR (G) FOR CHILLER UNIT, CAP 160.14,HVAC SYSTEM AFC PLANT. PART NO 55.400.11.503 | item13 | 3 | No. |
|---|
| 15 | 14 | WINDING PROTECTION UNIT, 220VAC Cap: 160.14, HVAC system AFC Plant. Part No: 56.125.50.012 | item14 | 1 | No. |
|---|
| 16 | 15 | CT 250 AMP WITH AC/DC CONVERTER CARD, 220VAC Cap: 160.14, HVAC system AFC Plant. Part No: 56.127.50.127 | item15 | 1 | No. |
|---|
| 17 | 16 | VOLTAGE PROTECTION DEUISE D2, 220VAC Cap: 160.14, HVAC system AFC Plant. Part No: 56.126.50.064 | item16 | 2 | No. |
|---|