| 1 | 1 | SCHEDULE 'A' PART-I (E/M WORKS) | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | Taking down carefully point wiring of any type (i.e. on wooden batten, surface conduit, casing-N- capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rawal plug, screw etc including making good disturbed surface to match the existing surface all as specified & directed. | | 560 | Each |
|---|
| 3 | 1.02 | M & L for point wiring with 1.5 Sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) Cable of working voltage 1100 Volts grade conforming to IS-694 pt-I & II of 2000 drawn in and including 25 mm size PVC rigid non matellic casing caping (Double lock) with all casing capping fittings & accessories with 1.60 mm thick pressed steel or mild steel sheet sunk box covered with 3 mm thick backelite sheet fixed with brass screws & cup washers including 1.5 sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) cable as earth continuity conductor connected to main switch / DB's or common earth dolly complete for for light point/ fan point/ exhaust fan point/ call bell point/ controlled by one switch 5/6 Amp one way complete all as specified and directed. | | 250 | Per Point |
|---|
| 4 | 1.03 | All as per item no.2 but one light point controlled by two 2-way switches 5/6 Amps | | 20 | Per Point |
|---|
| 5 | 1.04 | All as per item no.2 but One 3 pin socket outlet, 5 Amps on the same board with other switches | | 50 | Per Point |
|---|
| 6 | 1.05 | All as per item no.2 but socket outlet 3pin 5 amps independent board | | 140 | Per Point |
|---|
| 7 | 1.06 | All as per item No.2 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge | | 100 | Per Point |
|---|
| 8 | 1.07 | S&F in repairs switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge\nMake : Anchor Product Code No 50053 or equivalent of approved make | | 170 | Each |
|---|
| 9 | 1.08 | S&F in repairs switch piano flush button,single pole, two way, 6 amps complete.\nMake : Anchor Product Code No 50064 or equivalent of approved make | | 20 | Each |
|---|
| 10 | 1.09 | S&F in repairs bell push, flush type, 6 amps, 240 volts ISI marked all as specified and directed.\nMake : Anchor Product Code No 50075 or equivalent of approved make | | 30 | Each |
|---|
| 11 | 1.1 | S&F in repairs bell ding dong, AC single pole 220/240 volts white/ivory finish, surface type complete all as specified and directed.\nMake : Anchor Product Code No 8272 or equivalent of approved make | | 30 | Each |
|---|
| 12 | 1.11 | S&F in repairs switch socket combination, 2 and 3 pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as directed including taking down old one. Make : Anchor Product Code No 4056/50483 or equivalent of approved make | | 190 | Each |
|---|
| 13 | 1.12 | S&F in repairs switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose , flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete complete all as directed including taking down old one. Make : Anchor Cat No 38808/50665 or equivalent of approved make | | 100 | Each |
|---|
| 14 | 1.13 | S&F in repairs ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed\nMake : Anchor Product Code No 39040 or equivalent of approved make | | 100 | Each |
|---|
| 15 | 1.14 | S&F in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet/ PVC etc. as reqd 240 volts, ISI marked complete all as specified and directed\nMake : Anchor Product Code No 38660 or equivalent of approved make | | 50 | Each |
|---|
| 16 | 1.15 | S&F in repairs lamp holder angular/straight insulated body, with back plate suitable for batten fittings, white/ivory finish complete all as directed.\nMake : Anchor Product Code No 39527 or equivalent of approved make | | 50 | Each |
|---|
| 17 | 1.16 | S&F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps ,230 volt complete all as directed including taking down old unsv one. \n(Make : L&T cat No DBMPS120SD or equivalent of approved make | | 20 | Each |
|---|
| 18 | 1.17 | S&F in repairs sheet metal enclosure for 4 way Distribution Boards (DB’s), triple pole and neutral double door with IP-43 protection suitable for fixing MCB's/lsolators after and including taking down old DB with MCB complete all as specified and as directed.\n(Make : L&T cat No DBTPE004DD or equivalent of approved make | | 4 | Each |
|---|
| 19 | 1.18 | S&F in repairs sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way with 200 Amps rated copper bus bar double door type complete and including taking down old DB with MCB complete all as specified and as directed.vells/ABB/Legrand)\n(Make : L&T cat No DBSPN008DD or equivalent of approved make | | 8 | Each |
|---|
| 20 | 1.19 | S&F in repairs sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 4 way with 200 Amps rated copper bus bar double door type complete and including taking down old DB with MCB complete all as specified and as directed.\n(Make : L&T cat No DBSPN004DD or equivalent of approved make | | 4 | Each |
|---|
| 21 | 1.2 | S&F in repairs MCB single pole & neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge.\n(Make : L&T cat No BB20400C to BB20630C or equivalent of approved make | | 24 | Each |
|---|
| 22 | 1.21 | S&F in repairs MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. \n(Make : L&T cat No BB10060C to BB10320C or equivalent of approved make | | 48 | Each |
|---|
| 23 | 1.22 | S&F in repairs MCB, Triple pole & neutral, 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed \n(Make : L&T cat No BB40630C or equivalent of approved make) | | 4 | Each |
|---|
| 24 | 1.23 | S&F in repairs existing 36/40W T8 fittings with IP 20, Class I, LED light fitting 1 x 18 W (4 FT), CRI >=80, CT >=5700K, wall / surface mounted, integrated type, constructed of fire retardant engineering grade extruded plastic & decorative end caps with integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with suitable fixing arrangements complete including 01 No 18 W (4 FT) LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed. (Make : Havells Cat No REGALBATTEN8UPTO1X22WSSBSWH and Tube light Cat No TITANIANEO1213T8SSTL18WLED865SPC equivalent of approved make)\n | | 150 | Each |
|---|
| 25 | 1.24 | S&F in repairs existing 28W T5 fittings with IP 20, Class I, LED light fitting 1 x 18 W (4 FT), CRI >=80, CT >=5700K, wall / surface mounted, integrated type, constructed of fire retardant engineering grade extruded plastic & decorative end caps with integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with suitable fixing arrangements complete including 01 No 18 W (4 FT) LED Batten with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size all as specified and as directed. (Make : Havells Cat No LUMLINEPLUSBS18WLED865SPCSS or equivalent of approved make) | | 120 | Each |
|---|
| 26 | 1.25 | Supply and fix integrated LED bulk head fittings of 10 watts, presure die cast housing acrylic diffuser and frame with IP 66 protection complete all as specified and as directed Make : Havells Cat Part No.HEXAFT10WLED857SSYMBOPC or equivalent of approved make) | | 20 | Each |
|---|
| 27 | 1.26 | S&F in repairs aesthetically designed 2x2 LED flat panel for surface mounting which provides soft light and glare free illumination 34 watts, including and connecting up all as specified and as directed. (Make : Havells Cat No PLUTOSURFACE4X1PLS34WLED857S or equivalent of approved make) | | 20 | Each |
|---|
| 28 | 1.27 | S&F in repairs Exhaust Fan 250 mm Sweep, 1400 RPM, 240 Volt, AC 50 HZ, PVC body, including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement mortar complete all as specified and directed.( Make:- Havells Ventil Air - DX White or equivalent of approved make | | 8 | Each |
|---|
| 29 | 1.28 | Supply, install, testing & commissioning of electric water heater in repairs, storage vertical type, 4 star rated, 25 ltr capacity comprising of high wattage heating element for instant heating, extra thick inner tank of superior grade, rust & shock proof ABS outer body, non-ferrous pressure plate with & incl provn of 04 Nos grouting bolts suitably flushed to wall or any other surface incl water & electric connection with 3 core PVC insulated, sheathed, standed copper conductor cable/flexible chord complete all as specified and as directed. Make : - Havells Cat No - GHWAMGTWH025 or equivalent of approved make | | 3 | Each |
|---|
| 30 | 1.29 | M&L for submain wiring alongwith earth wire of size 2x6.0 Sqmm + 1x6 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and incl PVC casing and caping of adequate size with all accessories as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Three run of PVC wire with one runs of PVC casing and caping will be measured and paid as one length.) | | 100 | RM |
|---|
| 31 | 1.3 | M&L for submain wiring alongwith earth wire of size 2x4.0 Sqmm + 1x4 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and incl PVC casing and caping of adequate size with all accessories as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Three runs of PVC wire with one runs of PVC casing and caping will be measured and paid as one length.) | | 140 | RM |
|---|
| 32 | 1.31 | M & L for earthing in repairs complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and as directed . | | 8 | Each Job |
|---|