| 1 | 1 | Removing defective window/Split type air conditioner of any make and capacity from various locations fixed on walls, windows, etc and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site complete all as specified and directed. \nNOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.\n | | 14 | EACH JOB |
|---|
| 2 | 2 | Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary / new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. \nNote:-\n(a) Sealed unit compressor shall be measured and paid separately as supply only\n(b) If any item required to made equipment functional like capillary tube, copper pipe, etc is deemed to be included in quoted unit rate. | | 14 | EACH JOB |
|---|
| 3 | 3 | Taking out window/split type Air conditioner of any make and capacity from position and cleaning the cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner, checking of electrical connections and re-fixing the same at its original position and testing complete all as specified and directed. \nNOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.\n | | 14 | EACH JOB |
|---|
| 4 | 4 | Supply only the folowing items for AC complete all as specified and directed. \nNOTE:-\n(a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items.\n(b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required. \n(c) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months for all such replacement. If any compressor is burnt during the guaranty period the same shall be replaced by contractor without taking any extra cost including supply & charging refrigerent gas.\n | | | |
|---|
| 5 | 8.01 | New hermitically sealed / Rotary type compressor of Capacity 1.5 TR\nMake: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.\n | | 5 | EACH |
|---|
| 6 | 8.02 | New hermitically sealed / Rotary type compressor of Capacity 2.0 TR\nMake: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.\n | | 9 | EACH |
|---|
| 7 | 8.03 | FHP motor of capacity 1/5 to 1/18 HP, single phase, 920 RPM with starting and running capacitor suitable for window type AC. \nMake : AUE/Air master or equivalent as approved by GE.\n | | 5 | EACH |
|---|
| 8 | 8.04 | Starting capacitor 80-100 MFD /100-120 MFD /120-150 MFD. \nMake: Keltronor/Epcos as per recommanded by manufacturer or equivalent as approved by GE.\n\n | | 9 | EACH |
|---|
| 9 | 8.05 | Running Capacitor 45/50 MFD.\nMake : EPCOS or as per recommanded by manufacturer or equivalent as approved by GE.\n\n | | 4 | EACH |
|---|
| 10 | 8.06 | Running Capacitor 36 MFD.\nMake : EPCOS or as per recommanded by manufacturer or equivalent as approved by GE.\n\n | | 1 | EACH |
|---|
| 11 | 8.07 | Starting relay suitable for 1.0 /1.5 /2.0 TR compressor Make: HI-tech/Classic or as per recommanded by manufacturer or equivalent as approved by GE.\n | | 8 | EACH |
|---|
| 12 | 8.08 | Rotary/Push type selector switch suitable for 1.5/2.0 TR window type AC. | | 5 | EACH |
|---|
| 13 | 8.09 | Thermostat suitable for window / Split type A/C\nMake : INDFOSS/Godrej or as per recommanded by manufacturer or equivalent as approved by GE.\n | | 10 | EACH |
|---|
| 14 | 8.1 | Cover outer of GI Sheet heavy duty with painted for window type AC of capacity 1.5 / 2.0 TR \n | | 2 | EACH |
|---|
| 15 | 8.11 | Front grill for window type AC of any model all as required at site. Make: LG/ Lancer/ Blue star/ Fedder Lloyed/ Carrier | | 2 | EACH |
|---|
| 16 | 8.12 | Condenser/cooling fan blade suitable for window type AC of any make & capacity.\n | | 5 | EACH |
|---|
| 17 | 8.13 | Blower fan Motor suitable for split AC of any capacity & make. | | 10 | EACH |
|---|
| 18 | 8.14 | Remote PCB for a split type AC of any capacity & make. | | 9 | EACH |
|---|
| 19 | 8.15 | Blower both end coupling complete for split type AC of any make & Capacity all as required at site. \nMake: LG/ Lancer/ Blue star/ Fedder Lloyed/ Carrier | | 3 | EACH |
|---|
| 20 | 8.16 | Cooling coil suitable for split type AC of any make & capacity.\n | | 5 | EACH |
|---|
| 21 | 8.17 | Copper liquit line filter two / one way suitable for split AC of any capacity & make | | 10 | EACH |
|---|
| 22 | 8.18 | PVC rounded 3 core, 4.0 sqmm copper work shop cable\nMAKE: POLYCAB/ PLAZZA/ V-MARC/ HAVELLS as approved by GE | | 80 | RM |
|---|
| 23 | 9 | S&F in replacement wiring loom for air conditioners complete all as directed by Engr-in-Charge. | | 5 | EACH |
|---|
| 24 | 10 | S&F in replacement condenser/cooling coil suitable for split AC of any capacity & make including refrigerent gas, gas charging and welding, etc complete all as directed by Engr-in-Charge. | | 8 | EACH |
|---|
| 25 | 11 | M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as directed by Engr-in-Charge. | | 8 | EACH |
|---|
| 26 | 12 | Charging of refrigerant gas R-22 in window / split type air conditioners 1.5 / 2.0 TR at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed. \n | | 14 | KG |
|---|
| 27 | 13 | Cutting of damaged tray from window type AC of capacity 1.5/2.0 TR and M&L for providing tray of exisiting shape and size including all necessary works such as welding, nuts, bolts, drilling, etc complete all as specified and directed. \n | | 2 | EACH JOB |
|---|
| 28 | 14 | Taking down unserviceable voltage stabilizer of capacity 0.5 KVA to 5 KVA from site or MES store and and transporting to MES/ contractor workshop to carry out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations after repairing or depositing to MES store yard including testing on load at site complete all as specified and directed. \nNOTE:- \n(a) If the transformer is found burnt, the same shall be re-winded in the workshop of contractor as directed.\n(b) All spares such as relay, PCB, transformeer, etc shall be measured and paid separately as supply only.\n | | 25 | EACH JOB |
|---|
| 29 | 15 | Supply only the folowing items for voltage stablizers complete all as specified and directed. \nNOTE:-\n(a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items.\n(b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required. \n | | | |
|---|
| 30 | 15.01 | Main relay 24 Volts, 25 Amps make as per OEM | | 20 | EACH |
|---|
| 31 | 15.02 | Main Control circuit (PCB) | | 20 | EACH |
|---|
| 32 | 15.03 | Output terminal, 32 Amps | | 15 | EACH |
|---|
| 33 | 15.04 | Replacement of Censor Transformer make as per OEM | | 15 | EACH |
|---|
| 34 | 15.05 | Voltmeter make as per OEM | | 20 | EACH |
|---|
| 35 | 15.06 | Time delay 2-3 minutes, low voltage-180 volts AC and high voltage 260-Volt AC make as per OEM | | 19 | EACH |
|---|
| 36 | 16 | Taking oul old burnt winding work and M&L for rewinding 5 KVA voltage stabliser with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as directed by Engr-in-Charge. | | 15 | EACH |
|---|
| 37 | 17 | Taking oul old burnt winding work and M&L for rewinding 4 KVA / 3 KVA voltage stabliser with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as directed by Engr-in-Charge. | | 5 | EACH |
|---|
| 38 | 18 | Taking oul old burnt winding work and M&L for rewinding 2 KVA / 1 KVA voltage stabliser with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as directed by Engr-in-Charge. | | 5 | EACH |
|---|
| 39 | 19 | S&F in repairs single pole and neutral enclosure with two pin and earth, plug and socket, single phase, 240 V with & including 1 No single pole MCB, capacity 20 amps, `C` charactristic, breaking cap 10 KA and industial plug top complete all as specified and directed. \n[MAKE:-Legrand (Cat no. 607841) or equivalent in Siemens/ Schinder/L&T/ ABB/Havells]\n | | 40 | EACH |
|---|
| 40 | 20 | Transporting refrigerator of any make and capacity from MES Store Yard/site to contactor’s workshop for carrying out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations/MES store yard after repairing complete all as specified and directed. \nNOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.\n | | 10 | EACH JOB |
|---|
| 41 | 21 | Removing unserviceable burnt sealed compressor from refrigerator / Deep freezer and fixing only new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. \nNote:- \n(a) Sealed unit compressor shall be measured and paid separately as supply only.\n(b) If any item required to made equipment functional like capiliary, copper pipe, etc is deemed to be included in quoted unit rate. | | 5 | Each Job |
|---|
| 42 | 22 | Supply only the folowing items for refrigerator complete all as specified and directed. \nNOTE:-\n(a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items.\n(b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required. \n(c) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months for all such replacement. If any compressor is burnt during the guaranty period the same shall be replaced by contractor without taking any extra cost including supply & charging refrigerent gas.\n | | | |
|---|
| 43 | 22.01 | New sealed compressor suitable for refrigerator / Deep freezer of capacity 165 Ltr/ 286 Ltr/ 310 Ltr. Make:Emerson/Whirl pool /LG / Blue star or equivalent as approved by GE.\n\n | | 8 | Each |
|---|
| 44 | 22.02 | Relay suitable for refrigerator/Deep freezer 165/286/310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool or equivalent as approved by GE.\n | | 7 | Each |
|---|
| 45 | 22.03 | Over load suitable for refrigerator/Deep freezer 286/310 Make : INDFOSS/Godrej or equivalent as approved by GE.\n | | 5 | Each |
|---|
| 46 | 22.04 | Thermostate suitable for refrigerator/Deep freezer 165/286/310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool or equivalent as approved by GE.\n\n | | 5 | Each |
|---|
| 47 | 22.05 | PVC freezer door suitable for refrigerator any make & capacity. \n | | 4 | Each |
|---|
| 48 | 22.06 | Chiller tray of any make and capacity suitable for refrigerator. | | 4 | Each |
|---|
| 49 | 22.07 | Vegetable tray suitable for refrigirator of any make & capacity. | | 5 | Each |
|---|
| 50 | 22.08 | Shelves suitable for refrigirator of any make & capacity. | | 4 | Each |
|---|
| 51 | 22.09 | Magnetic rubber door gasket suitable for refrigerator of any make & capacity. \n | | 5 | Each |
|---|
| 52 | 22.1 | Freezer temp control fan motor suitable for refrigirator of any capacity and make as per original equipment manufacturer.. | | 8 | Each |
|---|
| 53 | 22.11 | Timer Box of suitable for Refrigirator double door of capacity 200/ 310 Ltr and make as per original equipment manufacturer..\n | | 8 | Each |
|---|
| 54 | 22.12 | PVC rounded 3 core, 2.5 Sqmm copper work shop cable. Make : National / Plaza / Polycab / Gloster | | 80 | RM |
|---|
| 55 | 22.13 | Freezer Box / Chiller Assembly complete with coil and chamber of any make and capacity suitable for refrigerator. | | 3 | Each |
|---|
| 56 | 22.14 | Fan motor suitable for deep freezer of any capacity and make as per original equipment manufacturer.. | | 5 | Each |
|---|
| 57 | 23 | Charging of refrigerant gas R-22 in refrigerators/Deep Freezers any capacity at site or contractor’s workshop including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line etc and testing complete all as specified and directed. \n | | 15 | KG |
|---|
| 58 | 24 | Charging of refrigerant gas HFC-134a in refrigerators/Deep Freezers any capacity at site or contractor’s workshop including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line etc and testing complete all as specified and directed. \n | | 12 | KG |
|---|
| 59 | 25 | Taking down/out water cooler of any make and capacity from various locations; transporting to contractor’s workshop for carrying out repairs as mentioned in respective items of Schedule ‘A’ including transporting back after repair fixing at site re-connecting electrical & water connection & its re-testing on load complete all as specified and directed. \n | | 15 | Each Job |
|---|
| 60 | 26 | Removing unserviceable burnt sealed unit compressor from water coolers and fixing only sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed by Engineer-in-Charge.\nNote:- \n(a) Sealed unit compressor shall be measured and paid separately as supply only.\n(b) If any item required to made equipment functional like capilliary, copper pipe, etc is deemed to be included in quoted unit rate. | | 14 | Each Job |
|---|
| 61 | 27 | Removing un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade, single phase 1/8 to 1/35 HP, suitable for up to 150 Ltr capacity water coolers including testing complete all as specified and directed. \n | | 8 | Each Job |
|---|
| 62 | 28 | Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete all as specified and directed. \n | | 15 | Each Job |
|---|
| 63 | 29 | Supply only the folowing items for water cooler complete all as specified and directed. \nNOTE:-\n(a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items.\n(b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required. \n(c) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months for all such replacement. If any compressor is burnt during the guaranty period the same shall be replaced by contractor without taking any extra cost including supply & charging refrigerent gas.\n | | | |
|---|
| 64 | 29.01 | New hermitically sealed unit compressor of Capcity -150 Ltr.\nMake: Kirloskar/Tecumsch/Whirl pool / Lelvinator / Hitachi / Electrolux or equivalent as approved by GE.\n | | 1 | Each |
|---|
| 65 | 29.02 | New sealed unit compressor suitable for water cooler 40 / 80 Ltr.\nMake: Kirloskar/Tecumsch/ Whirl pool / kelvinator / Hitachi / Electrolux or equivalent as approved by GE.\n | | 5 | Each |
|---|
| 66 | 29.03 | New sealed unit compressor suitable for water cooler 60 / 120 Ltr.\nMake: Kirloskar/Tecumsch/ Whirl pool / kelvinator / Hitachi / Electrolux or equivalent as approved by GE.\n | | 8 | Each |
|---|
| 67 | 29.04 | Relay & OLP suitable for water cooler of any make & capacity. Make: HI-tech/Classic or as per recommanded by manufacturer or equivalent as approved by GE.\n | | 7 | Each |
|---|
| 68 | 29.05 | Thermostat switch suitable for water cooler Make : - Indfos or as per recommanded by manufacturer or equivalent as approved by GE.\n | | 10 | Each |
|---|
| 69 | 29.06 | Push taps, chromiuyim plated suitable for water cooler capacity up to 150 Ltr (as per sample) [MAKE: PRAYAG/MARC/PLUMBER as approved by GE] | | 10 | Each |
|---|
| 70 | 29.07 | Fan motor blade size 12\" sweep suitable for FHP motor of water cooler | | 5 | Each |
|---|
| 71 | 29.08 | PVC flexible pipe transparent 15mm/20mm dia dia (as per sample)\n | | 40 | RM |
|---|
| 72 | 29.09 | PVC float valve 15 / 20 mm dia with rod & ball.\n[MAKE: PRAYAG/ POLYTUF]\n | | 12 | Each |
|---|
| 73 | 29.1 | Running Capacitor 4 MFD\nMake : EPCOS or as per recommanded by manufacturer or equivalent as approved by GE.\n\n | | 12 | Each |
|---|
| 74 | 29.11 | 3 pin plug top one way 5 Amp, 240V\nMake: Kinjal / Anchor / Cona\n | | 30 | Each |
|---|
| 75 | 29.12 | 3 pin plug top 15 Amp, 240V\nMake: Kinjal / Anchor / Cona\n | | 50 | Each |
|---|
| 76 | 29.13 | Industrial type three pin metal clad socket of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser. [MAKE:LEGRAND/L&T/C&S]\n | | 25 | Each |
|---|
| 77 | 29.14 | Industrial type three pin metal clad plug top of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser. [MAKE:LEGRAND/L&T/C&S]\n | | 25 | Each |
|---|
| 78 | 29.15 | Charging of refrigerant gas R-22 in water coolers of any capacity at site or contractor’s workshop including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line, etc and testing complete all as specified and directed. \n | | 14 | KG |
|---|
| 79 | 30 | S&F in replacement condenser/cooling coil suitable for water cooler of any capacity & make including refrigerent gas, gas charging and welding, etc complete all as directed by Engr-in-Charge. | | 11 | EACH |
|---|
| 80 | 31 | S&F in replacement switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed. \n[MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/HAVELLS as approved by GE] | | 110 | EACH |
|---|
| 81 | 32 | Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/overhauling, re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and directed. | | 50 | Each Job |
|---|
| 82 | 33 | M&L for replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified and directed. \n | | 50 | Set of Three |
|---|
| 83 | 34 | S&F in replacement PVC front grill/air diverter with selector switch and 2 No. indicator for Desert Cooler of any make and capacity complete all as specified and directed. | | 3 | Each Job |
|---|
| 84 | 35 | M&L for rewinding of stator of exhaust fan/kit fan 18” sweep, 900 RPM of any make with super quality winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enamel paint of gray colour complete all as specified and directed. \n | | 6 | Each |
|---|
| 85 | 36 | S&F in replacement submersible water lifting pump of capacity 1.25 M head ,230 Volts complete all as specified and directed. \nMake: Bansal or equivalent as approved by GE.\n | | 48 | Each |
|---|
| 86 | 37 | S&F Kit fan motor 450 mm Sweep 1350 / 1400 RPM complete all as specified and directed. Make : Everest / Summer Cool / Khatian | | 20 | Each |
|---|
| 87 | 38 | S&F in repairs capacitor 3.5 / 4 MFD for fan motor of desert cooler complete all as specified and as directed.\n[Make:-EPCOS / SYSCAP / ASIAN or equivalent as approved by GE]\n | | 36 | EACH |
|---|
| 88 | 39 | M&L in replacement desert cooler cabinet, locally fabricated with three side panels, front, top and water tank (size not less than 81.5cm x 80.5cm x 97.5cm) suitable for desert cooler of cap 5000/4000 cum per hour, fabricated with 1 mm thick mild steel galvanized iron sheet including gas welding at joint and testing for water tightness, with and including double diversion grills and grill box, 4 way PVC distributor, PVC pipe 3 to 4 mtr, wood wool pads, electric wiring for fan & pump controlled seperately with 5 amp piano switch and indicator lampos complete all as specified and as directed. | | 2 | EACH JOB |
|---|
| 89 | 40 | Deduct Schedule of credit (calculation will be done off line) Rs.24,268.00 | | | |
|---|