| 1 | 0.05 | DESCRIPTION OF ITEMS | | | |
|---|
| 2 | 1 | Taking down carefully storage water heater of capacity 25 to 50 ltr, dismantling inner tank & outer tank, pipe assembly, cleaning thoroughly with descaling liquid compound, overhauling complete to ensure, free & consistent flow of water through pipe outlet, bronze welding of inner tank if required at site, rethreading of inlet/outlet pipe 15mm dia, reassembling the same at existing/new place, testing/commissioning after re-installation at site complete all as specified & directed. \nNote: 1. Replacement of unserviceable parts if required, shall be measured and paid as under supply only separetely in relevant items. \n2. Unserviceable items retrived form this item shall be abstracted under sch of credit. | | 120 | Each \nJob |
|---|
| 3 | 2 | Supply only following parts for gysers of capacity 50/25/35 Ltrs of Make: Bajaj / Racold / Power Pack, (Make of parts shall be as per existing gyser make) : | | | |
|---|
| 4 | 2.01 | Heating element for 2 KW of geysers suitable for operation on 230V 50 Hz | | 120 | Each |
|---|
| 5 | 2.02 | Heating element for 1.5 KW of geysers suitable for operation on 230V 50 Hz | | 120 | Each |
|---|
| 6 | 2.03 | Thermostate unit fitting for various geyser capacity of 25/35/50 Ltr | | 120 | Each |
|---|
| 7 | 2.04 | Air release valve suitable for geyser (as per sample) \nMake: Ditz / Venus / Usha / Recold / Bajaj | | 80 | Each |
|---|
| 8 | 2.05 | PVC connection of 15 mm bore for hot/cold water supply with nut & washer at both end of length 450 mm | | 120 | Each |
|---|
| 9 | 2.06 | Appratus plate for water storage heater 25/35 ltr capacity complete with and including nuts, bolts, washers, rubber gasket so as to make it leak proof | | 30 | Each \n |
|---|
| 10 | 2.07 | Appratus plate for water storage heater 50 ltr capacity complete with and including nuts, bolts, washers, rubber gasket so as to make it leak proof | | 30 | Each \n |
|---|
| 11 | 2.08 | Insulating material of glass wool for storage type water heater (geyser)any make and size 25 to 50 ltr capacity | | 10 | KG |
|---|
| 12 | 2.09 | Neon lamp indicator square/round type | | 30 | Each \n |
|---|
| 13 | 2.1 | Rubber gasket suitable for 25/35/50 ltrs capacity storage water heater | | 30 | Each |
|---|
| 14 | 3 | M & L for painting on external surface with one coat of white synthetic enamel paint after filling cavities with filler, incl writing MES No in front side of outer surface of geyser in sign writing with black colour complete all as specified and directed. | | 50 | Each\nJob |
|---|
| 15 | 4 | S & F in replacement steel water tubing galvanized medium grade complete with all fittings like union, socket, nipple etc fixed to walls, ceiling or floor etc of size 15mm bore complete all as directed. | | 200 | RM |
|---|
| 16 | 5 | S & F in repair stop cock 15mm dia chromium plated screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed. | | 50 | Each |
|---|
| 17 | 6 | S & F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amp complete all as specified and directed. | | 50 | Each |
|---|
| 18 | 7 | S & F in replacement industrial plug top, 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 voltscomplete all as specified and directed. | | 50 | Each |
|---|
| 19 | 8 | S & F in replacement socket 3 pin industrial type 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 volts complete all as specified and directed. | | 50 | Each |
|---|
| 20 | 9 | S & F in replacement MCB single pole, 6-32 Amp complete all as specified and directed. | | 60 | Each |
|---|
| 21 | 10 | M & L for flushing the complete condensing unit of AC refrigirator and dep freezer, evaportar jointing and the compressor suction and delivery and search out leakage and rectify by means of breazing and delivery tubes and replacement the charging lines. Strainers capillary tube etc rectification of the leakage from the system vaccumising dehydrating oil including testing and commissioning of system complete all as specified and directed. | | 40 | Each \nJob |
|---|
| 22 | 11 | S & F in replacement of condensing unit and housing the unit of any make of the window type AC complete all as specified and directed. | | 10 | Each |
|---|
| 23 | 12 | Supply & charging of refrigerant gas R-134(a) suitable for envouirment friendly charging line on sealed unit of compressor of window type room AC 1.5/2.0 ton including crimping and resoldring to charging line, complete all as specified and directed. | | 15 | Each \nJob |
|---|
| 24 | 13 | Removing the unserviceable compressor unit from the window type room AC 1.5 ton and supply and fix new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 1.5 ton and all as specified and all as directed by Engineer-in-Charge. | | 2 | Each\n Job |
|---|
| 25 | 14 | Removing the unserviceable compressor unit from the window type room AC 2.0 ton and supply and fix new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 2.0 ton and all as specified and all as directed by Engineer-in-Charge. | | 2 | Each Job |
|---|
| 26 | 15 | S & F in replacement Evaporator coil for the 1.5 to 2.0 ton capacity AC of any make complete all as specified and directed. | | 8 | Each Job |
|---|
| 27 | 16 | Supply and fix in repair Front grill for the 1.5 to 2.0 ton capacity AC conditioners of any make of AC complete all as specified and directed. | | 2 | Each Job |
|---|
| 28 | 17 | Supply and fix in repair starting relay for the 1.5 to 2.0 ton capacity AC conditioners of any make and any type of AC complete all as specified and directed. | | 10 | Each |
|---|
| 29 | 18 | Supply and fix in repair starting capacitor 80-100 mfd for the 1.5 to 2.0 ton capacity A/C conditioners of any make of AC complete all as specified and directed. Make:Keltron | | 10 | Each |
|---|
| 30 | 19 | Supply and fix in repair running capacitor 36 mfd for the 1.5 to 2.0 ton capacity A/C conditioners of any make of AC complete all as specified and directed. Make:Keltron | | 10 | Each |
|---|
| 31 | 20 | Supply only Compressor mounting rubber bush (set of 3 Nos counted as one unit) | | 6 | Each Set |
|---|
| 32 | 21 | S & F in repair blower fan motor for split unit AC 1.5 ton to 2.0 ton (As per sample) complete all as specified and directed. | | 2 | Each |
|---|
| 33 | 22 | S & F in repair condenser Fan blade rings 1.5 to 2.0 ton (As per sample) blower complete all as specified. | | 8 | Each |
|---|
| 34 | 23 | Taking down unserviceable copper tube from window type AC 1.5 ton to 2.0 ton and supply & joint new copper tube for charging refrigerant gas in machine complete all as specified and directed. | | 20 | RM |
|---|
| 35 | 24 | S & F in repair thermostate unit including electronic relay eqpt and electronic plate for air conditioner incl taking down old thermostat complete all as specified and directed. | | 12 | Each |
|---|
| 36 | 25 | Disconnecting of unserviceable three core flexible cord from window type AC/Refrigerator/storage water heater / voltage stabilizers of any size, supply and S & F connect three core flexible cored of size 2.5 sqmm complete all as specified and directed | | 100 | RM |
|---|
| 37 | 26 | Cutting suction and discharge gas pipe line and taking out unsv compressor unit from refrigerator of 165/180 ltrs capacity and S&F new sealed compressor unit of same model or approved model of same capacity complete incl commissioning and testing after installation at site complete all as specified and directed.\n | | 6 | Each |
|---|
| 38 | 27 | ~Ditto~ all as item No. 26 above but refrigerator of capacity 210/310/320 ltrs complete all as specified and directed. | | 4 | Each |
|---|
| 39 | 28 | S & F in repair of cooling coil and housing of the refrigirater unit of any make.( 280 ltr to 310 ltr) complete all as specified and directed. | | 16 | Each |
|---|
| 40 | 29 | S & F relay for refrigerator including taking down old relay complete all as specified and directed. | | 25 | Each |
|---|
| 41 | 30 | S & F thermostate unit for refrigerator including taking down old thermostat complete all as specified and directed. | | 25 | Each |
|---|
| 42 | 31 | S&F pigmy lamp pin/thread type 15 watts 230 volts suitable for refrigerator incl removing old bulb/lamp, complete all as specified and directed. | | 15 | Each |
|---|
| 43 | 32 | S & F door gasket for refrigerator (as per sample) including taking down old door gasket & aligning door after opening from body incl inserting packing, welding, threading etc which so ever required to leave no air gap between door & body and top edge of refrigerator flushing with top surface of refrigerator of capacity 165/175 ltrs complete all as specified and directed. | | 4 | Each |
|---|
| 44 | 33 | ~Ditto~ all as item No. 32 above but for refrigerator of capacity 280/286/310 or 320 ltrs capacity complete all as specified and directed. | | 4 | Each |
|---|
| 45 | 34 | Taking out unserviceable lock from the refrigerator and S&F new lock with keys, complete all as specified and directed. | | 6 | Each Job |
|---|
| 46 | 35 | Dismantling unserviceble freezer defrosting fan from double door refrigerator and replaced with new freezer defrosting fan of same model/capacity 200 to 300ltr ,complete all as specified and directed | | 4 | Each Job |
|---|
| 47 | 36 | M & L for replacement of unserviceble/damage freezer cooling coil assembly complete of existing model of refrigerator 165/175 ltrs capacity complete all as specified and directed. | | 4 | Each |
|---|
| 48 | 37 | ~Ditto~ all as item No 36 above but refrigerator of 280/310/320 ltrs complete all as specified and directed. | | 4 | Each |
|---|
| 49 | 38 | Taking down unserviceable copper tube from any capacity of Refrigerator, supply & joint new copper tube for charging refrigerant gas in machine complete all as specified and directed. | | 20 | RM |
|---|
| 50 | 39 | Supply & charging refrigerant gas R-134(a) charging line on sealed unit of compressor of refrigerator for 165/175 Ltrs including crimping and resoldring to charging line, complete all as specified and directed. | | 30 | Each Job |
|---|
| 51 | 40 | ~Ditto~ all as per item No. 39 above but 280/310/320 ltrs, R-134(a) non CFC refrigerant gas complete all as specified and directed | | 15 | Each Job |
|---|
| 52 | 41 | Taking down unserviceable capillary from any capacity of Refrigerator, supply & joint new capillary for charging refrigerant gas in machine complete all as specified and directed. | | 15 | Each |
|---|
| 53 | 42 | Taking down old unserviceable liquid filter/drier from all capacity of Refrigerator, Supply & joint new liquid filter/drier for charging refrigerant gas in machine complete all as specified and directed. | | 24 | Each |
|---|
| 54 | 43 | Taking down old unserviceable for rewinding of wall mounted/cabin/table fan of 400mm sweep, with super enameled copper winding wire of suitable size and providing with suitable insulation to fan including replacement of wornout nut, bolt, washers, split pin etc., re assembling and testing on completion complete all as specified and directed for the following type of fans.\nNote:-1. The defective parts shell be mesured and paid in relivent items saperately.\n2. Unserviceable items retrived form this item shall be abstracted under sch of credit. | | 10 | Each Job |
|---|
| 55 | 44 | Supply only following components of fan in replacement of unserviceable item as per item No-43 | | | |
|---|
| 56 | 44.01 | Ball bearing for wall mounted/cabin/table fan (As per sample) | | 10 | Each |
|---|
| 57 | 44.02 | Capacitor 2.5 mfd , ± 5%, 440V, AC, 50 Hz | | 10 | Each |
|---|
| 58 | 45 | Disconnecting / taking down carefully exhaust fan from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cable inculding taking out burnt copper winding and rewinding with existing same gauge of super enameled copper wire of exhaust fan 450 mm sweep complete all as directed.\nNote:-1. The defective parts shell be mesured and paid in relivent items saperately.\n2. Unserviceable items retrived form this item shall be abstracted under sch of credit. | | 50 | Each Job |
|---|
| 59 | 46 | ~Ditto~ all as per item No. 48 above but exhaust fan 380/300 mm sweep | | 50 | Each Job |
|---|
| 60 | 47 | ~Ditto~ all as per item No. 48 above but exhaust fan 250/225 mm sweep | | 80 | Each Job |
|---|
| 61 | 48 | Supply only following components of exhaust fan in replacement of unserviceable item as per item No above | | | |
|---|
| 62 | 48.01 | Supply only Ball bearing for exhaust fan (As per sample) | | 50 | Each |
|---|
| 63 | 48.02 | Supply only blade assembly suitable for exhaust fan 375/380mm | | 50 | Each |
|---|
| 64 | 48.03 | Supply only blade assembly suitable for exhaust fan 250/225mm | | 30 | Each |
|---|
| 65 | 48.04 | Supply only blade assembly suitable for exhaust fan 450mm sweep | | 50 | Each |
|---|
| 66 | 49 | M & L for painting with one coat of paint with grey enameled paint on external surface of exhaust fan of any size, including frame and louvers and writing MES NO. on outer surface of motor with black enamel synthetic paint etc, complete all as specified and directed | | 100 | Each |
|---|
| 67 | 50 | Taking down burnt finned strip heater from winter heating plant of MH & S&F new finned strip heater of capacity 3.0 KW complete all as specified. Make-DASPASS | | 12 | Each |
|---|
| 68 | 51 | ~Ditto~ all as per item No.50 above but heater capacity 2.0 KW | | 12 | Each |
|---|
| 69 | 52 | Taking down and Disconnecting, dismantling winter heating plant of capacity 38 KW (AHU capacity 4600 CFM) installed in OT / ICU of 161 MH for complete overhauling/servicing and refitting in same position after reassembling including replacement of minor repairs Complete all as specified and directed by Engineer-in- Charge.\nNote:-1. The defective parts shell be mesured and paid in relivent items saperately. .\n2. Unserviceable items retrived form this item shall be abstracted under sch of credit. | | 2 | Each |
|---|
| 70 | 53 | ~Ditto~ all as per item No.52 above but winter heating plant of 10KW (AHU capacity 1400 CFM) installed in labor room of family ward, complete all as specified and directed . | | 1 | Each |
|---|
| 71 | 54 | Supply only following components of winter heating plant in replacement of unserviceable item as per item No above | | | |
|---|
| 72 | 54.01 | Supply only ‘V’ shape fan belt from blower assembly | | 2 | Each |
|---|
| 73 | 54.02 | Supply only unserviceable voltmeter from winter heating plant control board volt meter 0-500 volts of size 96 mm x 96 mm | | 1 | Each |
|---|
| 74 | 54.03 | Supply only ball bearing from blower fan assembly of winter heating plant of 10KW | | 2 | Each |
|---|
| 75 | 54.04 | Supply only ball bearing from blower fan assembly of winter heating plant of 38KW | | 2 | Each |
|---|
| 76 | 54.05 | Supply only cattle heater of any capacity from water tank of heating plant | | 2 | Each |
|---|
| 77 | 55 | Dismantling of existing unserviceable halogen bulb from OT shadow less light fitting & S&F new halogen lamp 12 volts, 50 watt, pin type & testing complete all as specified and directed. | | 10 | Each |
|---|
| 78 | 56 | Repair of EPU of shadow less light fitting, checking & replacing defective parts in electronic printed circuit board, checking & repairing of auto control circuit complete including & testing & replacement of burnt damaged relay etc complete all as specified and directed. | | 2 | Each Job |
|---|
| 79 | 57 | S & F in repaire voltage stabilizer with input voltage 110 volts to 290 volts and output 230 voltage with 50 Hz,of capacity 4 KVA suitable for refrigerator / AC incl taking down old voltage stabilizer complete all as specified and directed. | | 3 | Each |
|---|
| 80 | 58 | Repair of voltage stabilizer 0.5 /1.0 KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as specified and directed. | | 6 | Each Job |
|---|
| 81 | 59 | Repair of voltage stabilizer 3.0/4.0 KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as specified and directed. | | 6 | Each Job |
|---|
| 82 | 60 | Repair to voltage stabilizer 5.0 KVA by replacing worn out / burnt parts in electronic printed circuit, board, checking and repairing of automatic control circuit, replacement of damaged / burnt relay/transformer etc & calibrating the same complete all as specified and directed. | | 7 | Each Job |
|---|
| 83 | 61 | S & F time delay relay for voltage stabilizer 5 KVA (As per sample) including taking down old defective relay all as directed. | | 10 | Each |
|---|
| 84 | 62 | S & F time delay relay for voltage stabilizer 3 KVA / 4 KVA (As per sample) including taking down old defective relay all as directed. | | 10 | Each |
|---|
| 85 | 63 | Supply and fixing in replacement of battery 12 V 80 AH of shadow less lamp at operation therater of 161 MH complete all as specified and directed. Make: Exide / Amaron | | 2 | Each |
|---|
| 86 | 64 | M & L for earthing in replacement complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 5 of MES schedule 1991 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed. | | 7 | Each |
|---|