8516/Gwl/E8 Repair/Maintenance Of Gyser And Ceiling Fan Etc In The Area Of Age E/M At Morar Cantt Under Ge Gwalior , Taking Out Of Ceiling Fan From Site Or Store Yard Of Any Make , Any Description 1200 / 1400 Mm Sweep And Any Position/Locations For Repairs , Servicing , Overhauling , If Required , Dismantling And Opening The Ceiling Fans , Removing The Burnt Out Copper Winding And Insulating Material Such As Illuminous Paper , Glass Sleeving , Cleaning The Slots And Rewinding The Same With Supper Enamelled Copper Winding Wire Of Existing Wire Gauge ( Make Atlas ( Minal ) , National , Htp , Hwp , Shital Etc ) With Insulating Material , Insulating Varnishing And Reassembling The Ceiling Fan After Replacement Of Unserviceable Parts Such As Split Pin , Lock Nut , Rubber Packing , Clamp Of Condenser , Blade Nut , Rubber Reel Insulator , Nut Bolt , Plastic Fan Canopy And Including Three Core ( Work Shop Cable ) Stranded Copper Conductor Of Size 23/0 . 0076 Mm Insulated As Per Required Length . All Burnt Ceiling Fan To Be Check By The Engr In Charge Concern Je In Mes Store Yard And Maintain Register Then And Rewinding Work To Be Carried Out In Mes Store Yard . All The Ceiling Fan Checking , Burnt Ceiling Fan Rewinding And Testing At E/M Store Yard , Complete All As Specified And As Directed . , Taking Out Of Exhaust Fan From Site Or Store Yard Of Any Make , Any Description Of 450Mm Sweep And Any Position/Locations For Repairs , Servicing , Overhauling , Necessory Lathe Work If Required , ( Grinding , Polishing ) Etc . Dismantling & Opening The Exhaust Fans Removing The Burnt Out Copper Winding And Insulating Material , Illuminous Paper , Glass Sleeving , Cleaning The Slots And Rewinding The Same With Supper Enamelled Copper Winding Wire , ( Make:-Atlas ( Minal ) , National , Htp , Hwp , Shital Etc ) With Insulating Material , Insulating Varnishing And Reassembling The Exhaust Fans After Replacement Of Unserviceable Parts Such As Frame Nut , Rubber Packing , Clamp Of Condenser , And Including Pvc Three Core ( Workshop Cable ) Stranded Copper Conductor Cable Of Size 23/0 . 0076 Mm Insulated As Per Required Length . All The Exhaust Fan Checking And Burnt Exhaust Fan Rewinding And Testing At E/M Store Yard , Complete All As Specified And As Directed . , All As Per Item No 2 Here-In-Before But Exhuast Fan Of Size 230/250 Mm Sweep . , All As Per Item No 2 Here-In-Before But Exhuast Fan Of Size 300 Mm Sweep . , M & L For Necessory Lathe Work If Required For Taking Out Old Gun Metal Bush And Refixing Of Bush For Refixing New Ball Bearing By Lathe Work . , Taking Out Of Wall/Pedestal Fan Of Any Make , Any Description Of 400 Mm Sweep For Repairs , Servicing , Overhauling , Necessory Lath Work If Required ( Grinding , Polishing ) Etc . Dismantling & Opening The Wall/Pedstal Fans , Removing The Burnt Out Copper Winding And Insulating Material Illuminous Paper , Glass Sleeving , Cleaning The Slots And Rewinding The Same With Supper Enamelled Copper Winding Wire , ( Make:-Atlas ( Minal ) , National , Htp , Hwp , Shital Etc ) With Insulating Material , Insulating Varnishing And Reassembling The Wall/Pedstal Fans After Replacement Of Unserviceable Parts Such As Frame Nut , Knob , Regulator Switch , Clamp Of Condenser , And Including Pvc Three Core ( Workshop Cable ) Stranded Copper Conductor Cable Of Size 23/0 . 0076 Mm Insulated As Per Required Length . All The Wall / Pedestal Fan Rewinding And Testing At E/M Store Yard Complete All As Specified And As Directed . , Taking Out Of Ceiling Fan From Site Or Store Yard Of Any Make , Any Description , Any Sweep And Any Position For Repairs , Servicing , Overhauling Etc . Dismantling & Opening The Fans Checking Serviceability Of Parts , Overhauling , Cleaning , Oiling & Greasing , Fixing The Serviceable Parts And Reassembling The Fans After Replacement Of Unserviceable Parts Such As Split Pin , Lock Nut , Rubber Packing , Clamp Of Condenser , Blade Nut , Rubber Reel Insulator , Nut Bolt , Plastic Fan Canopy And Including Filling Material , Grinding , And Polishing Of Fan Motor Shaft If Required , And Including Twin Core Twisted Flexible Stranded Copper Conductor Cable Of Size 23/0 . 0076 Mm Insulated As Per Required Length Of 1200/1400 Mm Sweep And Testing Complete . Ceiling Fan Checking And Servicing At E/M Store Yard Complete All As Specified And Directed . , Disconnecting , Taking Out Of Exhaust Fans , Wall Bracket Fans And Air Circulater Fans Etc . From Site Of Any Make , Any Description , Any Sweep And Any Position/Locations ( I . E . Md Accn/Otm Accn ) For Repairs , Servicing , Overhauling Etc . Dismantling & Opening The Fans Checking Serviceability Of Parts , Overhauling , Cleaning , Oiling & Greasing , Fixing The Serviceable Parts And Reassembling The Fans After Replacement Of Unserviceable Parts Such As Split Pin , Lock Nut , Rubber Packing , Clamp Of Condenser , Blade Nut , And Including Filling Material , Grinding , And Polishing Of Fan Motor Shaft If Required , And Including Twin Core Twisted Flexible Stranded Copper Conductor Cable Of Size 23/0 . 0076 Mm Insulated As Per Required Length Of And Testing Complete All As Specified And As Directed . , Supply Only , The Following New Spare Parts Suitable For The Ceiling / Exhaust /Wall Bracket Fans & Pedstal Fans , Air Circulating Fans Etc . Of Any Description Any Sweep:- Note:- Fixing & Testing Charges Of These Items Are Deemed To Be Included In The Rates Quoted Under Sch A Item No 1 To 8Above . ( A ) Ball Bearing Campack Type 6302-2Z Make Skf/Hch/Nbc , ( B ) Ball Bearing Campack Type 6201-2Z Make Skf/Hch/Nbc , ( C ) Ball Bearing Campack Type 6202-2Z Make Skf/Hch/Nbc , ( D ) Ball Bearing Campack Type 6203-2Z Make Skf/Hch/Nbc , ( E ) Ball Bearing Campack Type 6204-2Z Make Skf/Hch/Nbc , ( F ) Capacitor Ceiling Fan Of Capacity 2 . 5 Mfd ( Pvc Body ) + 5% , 440 Volts 50 Hz Is - 1709 Aaphs T-Max 850 C . Make: Nicco , Siemens , Epcos & Tibcon & R . D . , ( G ) Capacitor Ceiling Fan Of Capacity 3 . 15 Mfd ( Pvc Body ) + 5% , 440 Volts 50 Hz Is - 1709 Aaphs T- Max 850 C . Make: Nicco , Siemens , Epcos & Tibcon & R . D , ( H ) Capacitor Ceiling Fan Of Capacity 4 . 00 Mfd ( Pvc Body ) + 5% , 440 Volts 50 Hz Is - 1709 Aaphs T-Max 850 C . Make: Nicco , Siemens , Epcos ) & R . D , ( J ) Gun Metal Bush -2 Nos With Shaft Rod Of Required Size Suitable For Exhast Fan 230/300 Mm Sweep , ( K ) Gun Metal Bush For Suitable Size Of Existing Motor Shaft For Ceiling Fan . , M&L , Two Coats Of Painting Of Ceiling Fan With Blade Sets Of Any Make Any Sweep Complete On Site Or Store With Synthetic Supper Enamel White Paint Of Approved Make By Brush Painting And Filling With Filler Including Preparation Of Surface Fan Blade ( Set Of Three ) Including Rewriting Mes No Of Fan In Capital Letters Of Height Not Less Than 20 Mm On Body With Black Japan Paint Complete All As Specified And As Directed . , All As Per Item No 19 Here-In-Before But Exhuast Fan Any Make Any Sweep With Synthetic Grey Paint -Ditto- . , S&F , In Replacement Of Hanging Clamp Of Ceiling Fan With Nut Bolt , Rubber Real Insulator And Split Pin Complete All As Specified And As Directed . , Desconnecting , Taking Out Old Existing Un Serviceable Fan Regulator Of Any Description & In Any Position / Location And Supplying And Fixing Connecting And Testing Resistance Type Fan Regulator Complete All As Specified And As Directed . Make : Bajaj / Havells / Orisson / Usha , Desconnecting , Taking Out Old Existing Un Serviceable Fan Regulator Of Any Description & In Any Position / Location And Supplying And Fixing Connecting And Testing Electronic Step Up Rotary Type Regulator 100 Watt Complete All As Specified And As Direct