| 1 | 1 | Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as directed by Engineer- in - charge. | | 84 | Cum |
|---|
| 2 | 2 | Dismantling expanded metal, any thickness or mesh, fixed with steel or wood fillets,not exceeding 4 Kg/sqm complete all as directed by Engineer in Charge. | | 4500 | SQM |
|---|
| 3 | 3 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as directed by Engineer in Charge. | | 2660 | RM |
|---|
| 4 | 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. | | 115 | QUINTAL |
|---|
| 5 | 5 | M&L excavation in trenches not exc. 1.5 m in depth and not exc 1.5 m wide in soft disintegrated rock for foundation or for Laying Cables...etc and getting out complete all as directed by Engineer in charge. | | 6111 | CUM |
|---|
| 6 | 6 | M&L cement concrete type D2 1:4:8 (40mm graded stone aggregate) in foundations filling and mass concrete all as specified and as directed by Engg in charge. | | 594 | CUM |
|---|
| 7 | 7 | M&L RCC Design mix M-30, using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engg in charge. | | 456 | CUM |
|---|
| 8 | 8 | M&L RCC Design mix M-30, using 20mm graded stone aggregate in Columns, pillars, piers, posts and struts complete all as directed by Engg in charge. | | 779 | CUM |
|---|
| 9 | 9 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;\nand similar work; vertical or to batter | | 1825 | SQM |
|---|
| 10 | 10 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as directed by Engg in charge. | | 10115 | SQM |
|---|
| 11 | 11 | Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as directed by Engg in charge. | | 5614 | SQM |
|---|
| 12 | 12 | M&L Reinforced Cement Concrete M30 using 20mm graded aggregate on Beams, bands, cantilevers, bressummers, lintels, Copings complete all as directed by Engg in charge. | | 630 | CUM |
|---|
| 13 | 13 | S & F Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clipscomplete all as directed by Engg in charge. | | 184122 | KG |
|---|
| 14 | 14 | M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed by Engg in charge. | | 70605 | KG |
|---|
| 15 | 15 | S&F 18-20mm thick pre formed filler for expansion joints in crumble as directed by Engineer in charge. | | 247 | SQM |
|---|
| 16 | 16 | M&L for Laterite stone masonry walling of square rubble brought upto courses exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engg in charge. | | 2481 | CUM |
|---|
| 17 | 17 | M&L Rendering 15 mm thick cement plaster on stone masonary surface in CM 1:4 and finishing the surface even and smooth with out using extra cement complete all as specified and directed by Engineer in charge. | | 32955 | SQM |
|---|
| 18 | 18 | M & L preparation of new plastered surface and applying two coats of cement based paint over a coat primer complete all as directed by Engg in charge. | | 32955 | SQM |
|---|
| 19 | 19 | S&F Mild steel framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;\nladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165complete all as directed by Engg in charge. | | 1390 | KG |
|---|
| 20 | 20 | Preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxid/zinc chrome primer all as specified and directed. | | 817 | SQM |
|---|
| 21 | 21 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/disintegrated rock. | | 4493 | CUM |
|---|
| 22 | 22 | Removing excavated material n exc. 500m and depositing where directed at a level n exc. 1.5 m above the starting point | | 3611 | CUM |
|---|
| 23 | 23 | Excavation in trenches exc. 1.5 m & n.exc 3.0m in depth and not exc 1.5 m wide in soft disintegrated rock for foundation and getting out as directed by Engg in charge. | | 273 | CUM |
|---|
| 24 | 24 | S & F for Mild Steel TMT bar 8mm dia cut to length bent to shape and binding with 0.9mm dia MS wire | | 785 | KG |
|---|
| 25 | 25 | Formwork to face of walls, retaining walls, similar pattern etc in vetical or to batter with rough finish surface of concrete. | | 5288 | SQM |
|---|
| 26 | 26 | M&L RCC M-30 as in retaining wall/basement of wall, ballast walls and the like of any thicknness, above top of footings, including attached pilasters & butteresses. | | 592 | CUM |
|---|
| 27 | 27 | M&L reinforced concrete pipes, class NP2, of 900mm dia laid and jointed complete with collars complete all as directed by Engg in charge. | | 400 | RM |
|---|
| 28 | 28 | M&L reinforced concrete pipes, class NP2, of 600mm dia laid and jointed complete with collars complete all as directed by Engg in charge. | | 30 | RM |
|---|
| 29 | 29 | M & L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even & smooth without using extra cement in cement plaster | | 3943 | SQM |
|---|
| 30 | 30 | M & L for Rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even & smooth without using extra cement in cement plaster | | 143 | SQM |
|---|
| 31 | 31 | M&L cement concrete Type C1 1:3:6 (20 mm graded aggregate)as in copings, kneelers, apex stones, bed plates, kerbs, the like including weathering, slightly rounded or chamfered angles and throating and all necessary formwork, as directed by Engg in charge. | | 0.7 | CUM |
|---|
| 32 | 32 | M&L for precast RCC slab 1:2:4 type B-1 using 20mm graded aggregate as in cover slab and set in CM 1:6 | | 10 | CUM |
|---|
| 33 | 33 | S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) GDE Fe 410-0 W (Gde E-250) quality A | | 1000 | KG |
|---|
| 34 | 34 | S&F framed brackets of angles or tees with webs and flanges cut to shape, driiled and countersunk for screw including binding and welding angles as necessary, gusset plates riveting etcconfirming to Fe 290, Gde E-165 complete all as directed by Engineer in charge. | | 16082 | KG |
|---|
| 35 | 35 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and\nprovision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as directed by Engg in charge. | | 461 | 100RM |
|---|
| 36 | 36 | S&F Barbed razor type Concertina fencing Coil ,9 SWG hot galvanised spring tensile wire of UTS 145 TO 150 N/Sqm, Z INC COATING 250 TO 300 GMS/ Sqm, dia of coil when un- stretched shall be 610 mm having minimum of coil (GI Strip) 1.625 Kg/Rm, hot dip galvanised razor ribbon tape of size 0.50 mm thickness,19 mm wide before wrapping on central core wire fixed with 1.66mm thick GI clips (minimum 25 Nos/ Rm) and special nut and bolts to hold two coils together and extra rows parallel/ wire of 10 gauge complete all as specified and directed by Engineer in charge. | | 513 | 10 RM |
|---|
| 37 | 37 | External Electric Supply: Excavation in trenches not exc 1.5m in wide and not exc 1.5 m in depth and getting out in soft / loose soil for laying of cables all as specified and directed. | | 2200 | CUM |
|---|
| 38 | 38 | Excavation in trenches not exc 1.5m in wide and not exc 1.5 m in depth and getting out in hard/dense soil for laying of cables all as specified and directed. | | 428 | CUM |
|---|
| 39 | 39 | Excavation in trenches not exc 1.5m in wide and exc 1.5 m in depth and getting out in soft / disintegrated rock depth beyond 1.5m for pole. | | 2 | CUM |
|---|
| 40 | 40 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point. | | 260 | CUM |
|---|
| 41 | 41 | Supply and laying un re-inforced precast concrete cable cover, class LV, type-I flat, size 250 mmx150 mmx40 mm / Factory made in trenches over and across the cable complete all as specified | | 65000 | EACH |
|---|
| 42 | 42 | Supply and laying un re-inforced precast concrete cable cover, class HV, type-I, flat size 300 mmx180 mmx40 mm /factory made in trenches over and across the cable complete all as specified | | 120 | EACH |
|---|
| 43 | 43 | supply and fix Steel tubular double swan Neck swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP SP-31 (9.00 metres\nlong) (Note:- Excavation, earth work, PCC etc shall be measured and paid seperately) | | 220 | EACH |
|---|
| 44 | 44 | Supply, Install, test and commissioning step down distribution transformer , out door type, copper wound of capacity 63 KVA, HT 11 KV 3 Phase, LT 433 Volts, 50 Hz, 3 phase 4 wire, vector group DYN 11, cooling ONAN with tapping on HT side to varying secondary voltage with in limit as per IS with off load tap changing facility of ± 7.5% in steps of 2.5% with cable entry box for HT and LT side all as perIS 1180 Part -1: 2014 delta wound including HV & LV cable terminal box with terminals for three phase and neutral on LT side with first fill of transformer oil etc mounted on raised PCC platform. | | 1 | EACH |
|---|
| 45 | 45 | Supply and errect RCC pole 11 mtr long,152mmX152mm at top and 152mm X 260mm at bottom,class 9 (Note:- Excavation, earth work, PCC etc shall be measured and paid seperately) | | 4 | EACH |
|---|
| 46 | 46 | M / L for Cross arms, bracings, supports, clamps and back plates fabricated from structral steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and including one primer coat one under coat one finishing coat of paint | | 6 | QUINTAL |
|---|
| 47 | 47 | M / L for Anti-climbing device ,spikes type fabricated out of M S bar (round square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole including one primer coat one under coat one finishing coat of paint | | 0.25 | QUINTAL |
|---|
| 48 | 48 | S & F Disc insulator,porcelain,vitreous 145mm height and 255 mm dia ball and socket type, white, brown or green, single disc assembly for working pressure 11000 Volts | | 6 | EACH |
|---|
| 49 | 49 | Pin type,porcelain,vitreous white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,150 mm height,150 mm dia for 11000 volts grade.including material and labour. | | 6 | EACH |
|---|
| 50 | 50 | M / L for Aluminium conductor steel reinforced of any size including binding wire etc | | 0.25 | QUINTAL |
|---|
| 51 | 51 | S & F Danger notice plate of 1.6 mm thick mild steel sheet,vitreous enmalled white,with letter, figure and convntional skull and bones in single red colour and fixing with MS clamps,bolts and nuts of approved size for HT 25X20 Cm | | 4 | EACH |
|---|
| 52 | 52 | S / Fix drop out/Expulsion fuses, single pole, HT 11000 Volts grade comprising of insulators, steel base frame, GI bolts, nuts etc of 25 Amps capacity. | | 3 | EACH |
|---|
| 53 | 53 | Supply and fix lighting arresters Metal oxide type complete with all fitting Transmission class discharge capacity 10 Kilo amps HT 11000 volts grade. | | 2 | SET OF THREE |
|---|
| 54 | 54 | M/L for plain cement concrete (1.3.6) type C2 using 40mm graded stone aggregate in foundations filling and mass concrete complete all as specified | | 21 | CUM |
|---|
| 55 | 55 | M/L for plain cement concrete (1:2:4) type B1 using 20mm graded stone aggregate for Pole copping including necessary form work complete all as specified and directed | | 5 | CUM |
|---|
| 56 | 56 | M&L laterite stone masonary well bonded plinth built in cement mortar 1:4 complete all as specified and directed. | | 7.6 | CUM |
|---|
| 57 | 57 | M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in flooring (150mm Thick) for foundation complete of transformer plinth complete all as specified and directed. | | 4 | SQM |
|---|
| 58 | 58 | Supply, Lay, Testing and commissioning UG cable XLPE insulated screened PVC bedded galvanized flat steel strip (A2XFY/2XFY) electric power cable 6.35 KV (UE) /11 KV (E) 11000 volts grade (Earthed) conf to IS 7098 Part - 2 with stranded aluminium conductor of size 3 core 95Sqmm | | 70 | RM |
|---|
| 59 | 59 | Supply & Install HT 11 KV outdoor type gang operated triple pole air break switch suitable for horozontal or vertical mounting complete with 9 insulators and steel frame, with operating mechanism worked from ground level complete of rating 200 Amps capacity. | | 2 | EACH |
|---|
| 60 | 60 | Supply and fix cable jointing kit for 11 KV grade (Earthed) cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 to 120 sqmm. | | 2 | EACH |
|---|
| 61 | 61 | Supply and fix cable jointing kit for 11 KV grade (Earthed) cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 to 120 sqmm. | | 1 | EACH |
|---|
| 62 | 62 | Supply/Fix ,test commissioning of LT weather proof panel board powder coated outdoor type double door shutter type made out of CRCA sheet 3.15mm thick outer and 1.6mm for inner door confirming to IS 8623 with MS angle iron 50x50x6mm floor mounting type with enclosed bus bar chamber and with Al bus bar of cap 200 Amp with necessary insulator suitable for 3 phase, 4 wire, 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-100A, digital voltemeter 0-500Volts, CT's of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.60 Mtr above ground level grouting etc all as specified and directed with including following items , including provision of suitable size of cable glands,cable lugs,nut,bolts,washers etc.The bottom poration of enclosure shall be minimum 60 cm above ground level of legs of angle iron \n (a) MCCB 4 pole 440 V 100 A 25 KA (Make : L&T Type: (Incoming)\n (b) MCB TPN 25 Amps-05 No (Out going/spare)\n (c) MCB SPN 16 Amps 10 KA - 02 Nos (Outgoing )\n (d) Three phase timer with conctactor-1 no | | 1 | EACH |
|---|
| 63 | 63 | :Supply/Fix ,test commissioning of LT weather proof panel board powder coated outdoor type double door shutter type made out of CRCA sheet 3mm thick outer and 1.6mm for inner door confirming to IS 8623 with MS angle iron 50x50x6mm floor mounting type with enclosed bus bar chamber and with aluminium bus bar of cap 200 Amp with necessary insulator suitable for 3 phase, 4 wire, 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-50A, digital voltemeter 0-500Volts, CT's of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.60 Mtr above ground level grouting etc all as specified and directed with including following items , including provision of suitable size of cable glands,cable lugs,nut,bolts,washers etc.The bottom poration of enclosure shall be minimum 60 cm above ground level of legs of angle iron \n (a) One set of Al bus bar suitable of 100 A \n (b) MCCB 4 pole 440 V 25 A 10 KA (Make : L&T Type: (Incoming from Main/Sub panel)\n (c) MCB TPN 12 Amps - 03 No \n | | 4 | EACH |
|---|
| 64 | 64 | Supply, install, test and commissioning APFC Panel of 30 KVAR 3 Phase 440 V Delta connected MPP-H type) outdoor type cubical panel board 3 phase 415 volts with 160 Amps rated Aluminium bus bar, IP 54, dust and vermine proof, free standing floor mounted made out of 3.15 mm thich CRCA sheet, duly powder coated complete with MCCB 3P 160 Amps, 25 KA, thermal magnetic release as incomer, MCB TP with contactor 3 pole 415 volts capacitor duty of suitable capacity for individual capacitors, APFC relay microprocessor based eight stages, auto manual control for each capacitor bank, volt meter 0-500 Volts digital type with inbuilt selector switch, Ammeter 0-160 Amps digital type with inbuilt selector switch and suitable CTs, indicator lamps for main supply and for each capacitor ON/OFF indication etc complete including necessary PCC platform of suitable size. | | 1 | EACH |
|---|
| 65 | 65 | Supply and fix New generation energy saving and environmental friendly long life LED 70 W street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. Make : Bajaj Cat No: LED Edge Plus or equivalent in philips/Crompton | | 440 | EACH |
|---|
| 66 | 66 | Supply and fix New generation energy saving and environmental friendly long life LED 70 W flood light made up of pressure die cast aluminium housing with high power LED as lighting source for general purpose lighting with IP65 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. Make : Philips Smart bright LED Flood light or equivalent in havells /Crompton/Halonix | | 6 | EACH |
|---|
| 67 | 67 | Supply and fix New generation energy saving and environmental friendly long life LED 350 W flood light made up of pressure die cast aluminium housing with high power LED as lighting sourcesuitable for high mast application with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. Make : Havells Cat No: JETAVALOURFL350W3MLED757 or equivalent in philips/Crompton/Halonix | | 4 | EACH |
|---|
| 68 | 69 | Supply, lay, testing and commissioning UG cable XLPE insulated, armored heavy duty electric cable, 1100 volts grade with stranded aluminium conductor in trenches including suitable size of double grip cable gland and joiinting etc complete for the following sizes :- (a) Supply/Lay LT UG cable 3.5 core 70 Sqmm. | | 3900 | RM |
|---|
| 69 | 70 | (b) Supply/Lay LT UG cable 3.5 core 35 Sqmm. | | 1500 | RM |
|---|
| 70 | 71 | (c) Supply/Lay LT UG cable 4 core 25 Sqmm. | | 4375 | RM |
|---|
| 71 | 72 | Supply and laying or fixing or passing through PVC pipe 20 mm dia on pole / wall,1100 volts grade unarmoured cable with PVC insulated copper conductor 2.5 Sqmm 2 Core for connection of 70 W LED street light lights from junction box. | | 252 | RM |
|---|
| 72 | 73 | M & L for bracket made out of GI tubing 40 mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia with - 4 Nos & flat washer (3mm thick) 01 no suitable f for LT RCC poles each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.For fixing flood light) | | 10 | EACH |
|---|
| 73 | 74 | Supply and lay GI pipe light grade as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified (a) 100 mm dia | | 20 | RM |
|---|
| 74 | 75 | Supply and lay GI pipe light grade as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified (b) 50 mm dia | | 40 | RM |
|---|
| 75 | 76 | Earthing complete with galvanized iron earth plate electrode 600x600 x6.0mm thick buried directly in ground( earth pit not less than2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level ,connected to galvanized iron strip of size 32x6 mm as earthing lead by means of nuts and bolts check nuts and washers of galvanized iron connected to test point, GI tubing 40mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt,Ci cover with suitable handle,PCC pit 1:2:4 including earth work in any type of soil and connecting to earthing test point/panel and testig on completion all as shown on electrical plate No -3 of SSR 2009- Part 1. | | 18 | EACH |
|---|
| 76 | 77 | Material and labour for loose filling with aggregates of gauge 40-80mm in floor area of 11 KV sub station yard all as directed by engr-in-charge. | | 4.5 | CUM |
|---|