Overhauling Of Critical Pumps Of Power House , Cwph And Cooling Towers Of Unit-1 To 10 , O/H Of 16Fc Valve Of Cooling Tower , As Per Scope Of Work . , Repl . Of Defective Weldment Of Sr-36 Gea , As Per Scope Of Work . , Repl . Of Ct 1-6 Fan Assy , As Per Scope Of Work . , Repl . Of Driveshaft Of Ct 1-6 Fan , As Per Scope Of Work . , Changing Of D . S . Rubber Bush ( 1-6 ) , As Per Scope Of Work . , Fan Blade End Clearance And Pitch ( 1-6 ) , As Per Scope Of Work . , Elimination Of Endplay Of Sr-36 Gearbox , As Per Scope Of Work . , Sr-36 Gearbox Input Shaft Oilseal Changi , As Per Scope Of Work . , Sr-36 Gearbox Output Shaft O Ring , As Per Scope Of Work . , Driveshaft Alignment Of Sr-36 Gearbox , As Per Scope Of Work . , Misc . Welding Jobs In Ct 1-6 , As Per Scope Of Work . , Misc . Cutting Jobs In Ct 1-6 , As Per Scope Of Work . , O/H Of Boiler Feed Pump , As Per Scope Of Work . , Mechanical Seal Replacement Of Bfp , As Per Scope Of Work . , Cartridge Repl . /Discharge O-Ring Replace , As Per Scope Of Work . , Alignment , Coupling & Trial Run Of The Pu , As Per Scope Of Work . , Bearing Inspection Of Bfp , As Per Scope Of Work . , O/H Of Booster Pump , As Per Scope Of Work . , M . Seal /S . Box Gasket Replacement Of Bp , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of Bp , As Per Scope Of Work . , Bearing Inspection Of Bp , As Per Scope Of Work . , Dismantling Of B . Pump And Re-Assembly , As Per Scope Of Work . , O/H Condensate Extraction Pump , As Per Scope Of Work . , Stage Body Dismantling And Re-Assembly , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of Cep , As Per Scope Of Work . , S . Box Sleeve Repl . And Brg . Inspection , As Per Scope Of Work . , Gland Replacement Of Cep , As Per Scope Of Work . , O/H Of Cw Pump , As Per Scope Of Work . , Tbh Inspection/Repl . Of Cw Pump , As Per Scope Of Work . , Stuf . Box Inspection/Repl . Of Cw Pump , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of Cw Pum , As Per Scope Of Work . , Gland Replacement Oof Cw Pump , As Per Scope Of Work . , O/H Of Acw Pump , As Per Scope Of Work . , Tbh Inspection/Repl . Of Acw Pump , As Per Scope Of Work . , Stuf . Box Inspection/Repl . Of Acw Pump , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of Acw Pu , As Per Scope Of Work . , Gland Replacement Of Acw Pump , As Per Scope Of Work . , O/H Of Fire Fighting Pump , As Per Scope Of Work . , Tbh Inspection/Repl . Of F/F Pump , As Per Scope Of Work . , Stuf . Box Inspection/Repl . Of F/F Pump , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of F/F Pu , As Per Scope Of Work . , Gland Replacement Of F/F Pump , As Per Scope Of Work . , Stage Body Dismantling And Re-Assembly , As Per Scope Of Work . , O/H Of C . T . Pump , As Per Scope Of Work . , Tbh Inspection/Repl . Of Ct Pump , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of Ct Pum , As Per Scope Of Work . , Gland Replacement Of Ct Pump , As Per Scope Of Work . , Dismantling And Re-Assembly Of Ct Pump , As Per Scope Of Work . , Synthetic Enamel Painting Of P . H . , As Per Scope Of Work . , Chloro Rubber Painting Of Ct 1-6 , As Per Scope Of Work . , Repl . Of Damaged Target Nozzles Of Ct , As Per Scope Of Work . , O/H Of Aux . Aop/Eop/Mop , As Per Scope Of Work . , Insp . /Repl . Of Coupling Bushes Of Aop/Eo , As Per Scope Of Work . , Insp/Repl . Of Bearings Aop/Eop/Mop , As Per Scope Of Work . , O/H Of Jacking Oil Pump , As Per Scope Of Work . , Repl . Of Cw/Acw Outlet Bfv , As Per Scope Of Work . , Overhauling Of Cw/Acw Bfv , As Per Scope Of Work . , Replacement Of 400Nb Pipe , As Per Scope Of Work . , Pm Of 20/5T Cwph Crane , As Per Scope Of Work . , Repl . Of Cw Inter-Connection Valve , As Per Scope Of Work . , O/H Of Sluice Gate At Ct Discharge , As Per Scope Of Work . , Repl . Of Cw/Acw R . E . Joint , As Per Scope Of Work . , Overhauling Of Dmcw/Boiler Fill Pump , As Per Scope Of Work . , O/H Of 18Fc Valve Of Cooling Tower ( Uni , As Per Scope Of Work . , Repl . Of Defective Weldment Of Gear Box , As Per Scope Of Work . , Repl . Of Cooling Tower Fan Assy . ( Unit 7 , As Per Scope Of Work . , Repl . Of Driveshaft Of Coolingtower Fan ( , As Per Scope Of Work . , Changing Of Neoprene Bonded Rubber ( Uni , As Per Scope Of Work . , Fan Blade End Clearance And Pitch ( Unit , As Per Scope Of Work . , Elimination Of End Play Of Gearbox Sr-3 , As Per Scope Of Work . , Gearbox Sr-32 Input Shaft Oilseal Changi , As Per Scope Of Work . , Gearbox Sr -32 Output Shaft O Ring ( U , As Per Scope Of Work . , Driveshaft Alignment At Gearbox Sr-32 ( U , As Per Scope Of Work . , Misc . Welding Jobs In Cooling Tower ( Un , As Per Scope Of Work . , Misc . Cutting Jobs In Cooling Tower ( Uni , As Per Scope Of Work . , O/H Of Cooling Water Pump At Rcph . , As Per Scope Of Work . , Tbh Inspection/Repl . Of Cw Pumps At Rcph , As Per Scope Of Work . , Stuf . Box Inspection/Repl . Rcph , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of Cw Pum , As Per Scope Of Work . , Gland Replacement Of Cw P/P At Rcph , As Per Scope Of Work . , O/H Of Aux . Cooling Water Pump At Rcph . , As Per Scope Of Work . , Tbh Inspection/Repl . Of Acw P/P At Rcph , As Per Scope Of Work . , Stuf . Box Inspection/Repl . Rcph , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of Acw P , As Per Scope Of Work . , Gland Replacement Of Acw P/P At Rcph , As Per Scope Of Work . , O/H Of Firefighting Pump At Rcph , As Per Scope Of Work . , Tbh Inspection/Repl . Of F/F Pump At Rcph , As Per Scope Of Work . , Stuf . Box Inspection/Repl . Of F/F Pump At , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of F/F Pu , As Per Scope Of Work . , Gland Replacementof F/F Pump At Rcph , As Per Scope Of Work . , Stage Body Dismantling And Re-Assembly R , As Per Scope Of Work . , Synthetic Enamel Painting Cooling Tower , As Per Scope Of Work . , Chloro Rubber Painting At Cooling Tower , As Per Scope Of Work . , Repl . Of Damaged Target Nozzles Of Ct ( Un , As Per Scope Of Work . , Repl . Of Cw/Acw Outlet Bfv At Rcph . , As Per Scope Of Work . , Overhauling Of Cw/Acw Bfv At Rcph . , As Per Scope Of Work . , Replacement Of 400Nb Pipe Ct ( Unit 7 -10 , As Per Scope Of Work . , Pm , & Loadtesting Of 25/5T Crane At Rcph , As Per Scope Of Work . , Repl . Of Rcph Cw Inter-Connection Valve , As Per Scope Of Work . , O/H Of Sluice Gate At Ct Discharge Uni , As Per Scope Of Work . , Repl . Of Cw/Acw R . E . Joint At Rcph . , As Per Scope Of Work . , O/H Of Intake Pump , As Per Scope Of Work . , Tbh Inspection/Repl . Of Ip . , As Per Scope Of Work . , Stuf . Box Inspection/Repl . Of I . Pump . , As Per Scope Of Work . , Alignment , Coupling & Trail Run Of I . Pump , As Per Scope Of Work . , Gland Replacement Of I . Pump . , As Per Scope Of Work . , Overhauling Of Voithhydrocoupling Of Bfp , As Per Scope Of Work . , Servicing Of Nrv ( 600Nb ) Of Acw Pump , As Per Scope Of Work . , Servicing Of Nrv ( 1200Nb ) Of Cw Pump , As Per Scope Of Work . , Minor Overhauling Of Cooling Tower Fan , As Per Scope Of Work .