Repair / Maintenance Of Security Lights Times Switches And Connected Items At Babina Cantt - 1 S & F In Replacement Led Street Light 45 Watt ( Edge Led ) New Generation, Energy Saving And Environmental Friendly Long Life Made Up Of Innovative Die Cast Aluminium Housing High Power Led As Lighting Source With Ip - 66 , Input Voltage Of 150-240 Volt ( Nominal Rated Voltage 240 Volt ) Complete Including Taking Down Of Old Unserviceable Street Light From Pole Or Any Other Location Any Type / Any Capacity Including Replacement Of 3 Core Copper Cable Twisted Of Size 1.5 Sqmm Dia For Connecting Phase, Neutral And Earth From Junction Box To Light Throgh Copper Connectos All As Specified And Directed. Make : Bajaj Cat Part No Brtfg45 W Led I White Or Equivalent In Havells / Wipro / Crompton / Philips 2 S & F In Replacement Led Street Light 60 Watt ( Edge Led ) New Generation, Energy Saving And Environmental Friendly Long Life Made Up Of Innovative Die Cast Aluminium Housing High Power Led As Lighting Source With Ip - 66 , Input Voltage Of 150-240 Volt ( Nominal Rated Voltage 240 Volt ) Complete Including Taking Down Of Old Unserviceable Street Light From Pole Or Any Other Location Any Type / Any Capacity Including Replacement Of 3 Core Copper Cable Twisted Of Size 1.5 Sqmm Dia For Connecting Phase, Neutral And Earth From Junction Box To Light Throgh Copper Connectos All As Specified And Directed. Make : Bajaj Cat Part No Brtfg60 W Led V3 White Or Equivalent In Havells / Wipro / Crompton / Philips 3 S & F In Replacement Led Street Light 90 Watt ( Edge Led ) New Generation, Energy Saving And Environmental Friendly Long Life Made Up Of Innovative Die Cast Aluminium Housing High Power Led As Lighting Source With Ip - 66 , Input Voltage Of 150-240 Volt ( Nominal Rated Voltage 240 Volt ) Complete Including Taking Down Of Old Unserviceable Street Light From Pole Or Any Other Location Any Type / Any Capacity Including Replacement Of 3 Core Copper Cable Twisted Of Size 1.5 Sqmm Dia For Connecting Phase, Neutral And Earth From Junction Box To Light Throgh Copper Connectos All As Specified And Directed. Make : Bajaj Cat Part No Brtfg90 W Led I V2 White Or Equivalent In Havells / Wipro / Crompton / Philips 4 S & F In Replacement Gi Brackets For Led Street Light Fitting Fabricated With Gi Tubing Not Less Than 40 Mm Dia Medium Grade 1.2 Mtr Long Bend To 120 Degree Shape By Cutting, Welding And Well Finishing Including Ms Clamp Of Flat Iron Of Size 32 X 6 Mm Suitable Length 02 Nos Complete For Steel Poles / Pcc Pole As Per Site Requirement With Nut, Bolt & Washers For Fixing Of Gi Bracket Complete All As Specified And Directed. Make : Jindal / Tata / Prakash Surya 5 S & F Looping Box Outdoor Type Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Front Openable Including Locking Arrangements Including Three Phase Copper Bus Bar 16 Amp Rated In Each Bus Bar Including Mcb Of Capacity 16 Amp Complete Fix To Pole With Necessary Clamps Of Size 32X6 Mm & Nuts, Bolts & Washers Complete All As Specified And Directed. Make -Sintex Or Any Other Equivalent Make Approved By The Ge 6 Supply, Laying, Conntecting And Testing Underground Cable, Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor 16 Sqmm 4 Core 1100 Volts Grade Cross-Sectional Area Incl Taking Down Complete All As Specified And Directed 7 Supply, Laying, Conntecting And Testing Underground Cable, Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor 10 Sqmm 4 Core 1100 Volts Grade Cross-Sectional Area Incl Taking Down Complete All As Specified And Directed 8 Supply, Laying, Conntecting And Testing Underground Cable, Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor 6 Sqmm 2 Core 1100 Volts Grade Cross-Sectional Area Incl Taking Down Complete All As Specified And Directed 9 M&L For Steel Tubing Galvanised, 50 Mm Bore , Light Grade Complete With Fittings Laid In Trenches / Fixed Along With Poles Etc As Protection To Cables Etc Complete All As Specified And As Directed. 10 M&L For Steel Tubing Galvanised, 40 Mm Bore , Light Grade Complete With Fittings Laid In Trenches / Fixed Along With Poles Etc As Protection To Cables Etc Complete All As Specified And As Directed. Make : Jindal / Tata / Prakash Surya 11 Supply , Fixing And Testing Of 3 Phase Automatic Street Light Switch Using Integrated Sensor Based Nature Switch For Automatic Switching Of Street Lights Based On Lux Level Of Natural Light Required Illuminance For Switching On Is ‹ 30 Lux And For Switching Off › 10 Lux Level. The Sensor ( Nature Switch ) Along With Suitable Power Contactors Input ( Supply ) Mcb And Output ( Load ) Mcb ( S ) , Support Terminals Should Be Enclosed In Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof , Termite Proof And Fr Graded Smc Junction Box Conforming Of Ip 66 Degree Of Ingress Three Phase 12 Kw Lightning Load Capacity Including Mounting Bracket , Cable Glands, Openable Doors With Lock Complete All As Specified And Directed. The Contactor Mcb And Circuit Wiring Should Suitable Enough To Take Load Of 12 Kw Equally Distributed Over Three Phase And Street Light Timer Should Be Comprising Of Following:- ( A ) . Input Mcb ( 3 Nos ) Rating 63 Amps ( B ) .Contactor Mcb ( 3 Nos ) Rating 63 Amps ( C ) .Out Put Mcb ( 3 Nos ) Rating 63 Amps ( D ) .Three Phase Circuit Wiring Minimum 10 Sqmm Multistranded Copper Wire. Make & Model -Swadeep -66 12 Kw3p Of Kakatiya Energy Systems Ltd Or Equivalent Make As On Approved List Of Hqs 12 Supply , Fixing And Testing Of Single Phase Automatic Street Light Switch Using Integrated Sensor Based Nature Switch For Automatic Switching Of Street Lights Based On Lux Level Of Natural Light Required Illuminance For Switching On Is ‹ 30 Lux And For Switching Off › 10 Lux Level. The Sensor ( Nature Switch ) Along With Suitable Power Contactors Input ( Supply ) Mcb And Output ( Load ) Mcb ( S ) , Support Terminals Should Be Enclosed In Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof , Termite Proof And Fr Graded Smc Junction Box Conforming Of Ip 66 Degree Of Ingress Three Phase 8Kw Lightning Load Capacity Including Mounting Bracket , Cable Glands, Openable Doors With Lock Complete All As Specified And Directed. The Contactor Mcb And Circuit Wiring Should Suitable Enough To Take Load Of 8 Kw Equally Distributed Over Three Phase And Street Light Timer Should Be Comprising Of Following:- ( A ) . Input Mcb Rating 63 Amps ( B ) .Contactor Mcb Rating 63 Amps ( C ) .Out Put Mcb Rating 63 Amps ( D ) .Three Phase Circuit Wiring Minimum 10 Sqmm Multistranded Copper Wire. Make & Model -Swadeep -66 8 Kw1p Of Kakatiya Energy Systems Ltd Or Equivalent Make As On Approved List Of Hqs 13 S & F Cross Arms, Bracing, Supports Clamps And Back Plates Fabricated From Structural Steel Sections Incl Nuts & Bolts, Washers, Welding Bending Cold Or Hot, Drilling Holes For Bolts In Any Shape Or Size As Directed And Inclusive Of One Red Oxide Primer Coat, One Under Coat And One Finishing Coat Of Synthetic Enamel Paint Incl Taking Down Old Unserviceable Mild Steel Frame Work Complete All As Specified And Directed. 14 S & F Incl Stringing Gi Continuous Gi Earth Wire Of Size 4 Mm / 3.15 Mm Dia On Ht / Lt Poles As In Cradle Guards / Earth Wires, Binding Including Taking Down Complete All As Specified & Directed. 15 S&F In Replacement Aluminium Conductor, Steel Reinforced ( Acsr ) Of Any Size / Description On Ht / Lt Poles / Lines Including Stringing, Tightening, Binding To Insulators With Aluminium Wire Making And Connecting Jumpers, Connections Etc Including Connecting, Commissioning And Testing Incl Taking Down Old Unserviceable Acsr Conductor From Its Location / Position Complete All As Specified & Directed. Note- Old Spacers Obtained From Taking Down Of Acsr Conductor Shall Be Reused And Fixed As Directed. Make: Kuber / Alind / India Aluminium Co / Vk Conductors / Bharat Conductor 16 M & L For Road Cutting / Excavation In Trenches In Any Type Of Starta Met For Laying Of Electric Cable / Pipe , Width Of Trench 0.45 M Wide And Depth Exc .60 M But N Exc 1.00 M And Including Providing Pcc 1: 2:4 Type B-2 Using 40 Mm Graded Stone Aggregates 300 Mm Thick From Top Of Road Surface Over 75 Mm Thick Hard Core Over Rammed Earth ( Soils Reused ) In Remaining Thickness After Laying Of Electric Cable / Pipe Trench Etc Complete All As Specified And Directed. 17 M&L For Earthing Complete Including Necessary Excavation And Earth Work In Any Type Of Soil With Galvanized Steel Earth Plate Electrode Size 60 Cm X 60 Cm X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtrs Below Ground Level ) With Top Edge Of The Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level Connected To Galvanised Earth Lead 4.0 Mm Dia By Means Of Bolts Nuts Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No.5 Of Mes Ssr Part-1 Connected To Main Switch Board Or Main Control Board All As Specified And Testing On Completion Including Provision Of Earth Wire Protected By Galvanised Iron 40 Mm Dia. Light Grade Pipe And Watering Pipe Shall Be 20 Mm Ore Medium Grade Pcc Pipt With Pre Cast Rcc Cover, Charcoal / Salt Funnel Etc. Complete All As Directed. Note : The Conctrete Pit Shall Be Pcc 1:3:6 Type C1, 40 Mm Thick Pcc Slab Of Rcc ( 1:2:4 ) Type B-1 Using 20 Mm Graded Stone Aggregate Reinforced With 8 Mm Tmt Bars On Both Sides With Suitable Cast Iron Handle Shall Be Provided In Lieu Of Cast Iron Cover Shown In Electrical Plate No.5 Of Mes Ssr Part-1 ( Ii ) Pcc Pits Shall Be Provided Atleast 500 Mm Away From The Pit And Not On The Earth Pit Itself And The Extra Cost Of Additional Length Of Watering Pipe, Bends, Elbows Etc Shall Be Deemed To Included In The Quoted Rate. 18 S&F In Replacement Danger Notice Plate Of 1.6 Mm Thick Mild Steel Sheet Vitreous Enamaled White, With Letters, Figures And Conventional Skull And Bones In Post Office Red Colour Duly Painted And Written With Enamelled Paint Fixed With And Including Ms Clamps, Bolts And Nuts Of Approved Size For Lt, 20X15 Cm Size Complete All As Specified And Directed. 19 S & F In Replacement Of Pin Type Porcelain, Vitreous, White, Brown Or Green Insulators, Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Iron Nut, 1100 Volt Grade 100 Mm Height And 65 Mm Dia Suitable For Working Pressure Incl Taking Dwon Complete All As Specified And Directed .Make: Jaipuria Brothers / Bengal Potteries / Bhel / Sounthern Insulators 20 S & F In Replacement Of Shackle Type 75 Mm Height And 90 Mm Dia Insulator, Porcelain, Vitreous, White, Brown Or Green Incl Galvanised Mild Steel Strap 31 Mm X 3 Mm, Insulator Bolts 12 Mm Dia With Suitable Washers And Nut, Suitable For Working Pressure Upto 1100 Volt & Including Taking Down Complete All As Specified And Directed .Make: Jaipuria Brothers / Bengal Potteries / Bhel / Sounthern Insulators 21 M&L For Stay Assembly Of Ms Galvanised Stay Plate 230Mm X 230Mm X 6Mm Thick Ms Galvanised Tay Rod 20 Mm Dia With Nut 100 Cm Long Ms Galvanised Stay Bow 40 Cm Long And 14 Mm Dia With 2 Nos Galvanised Thimble With And Incl All Fittings All As Specified In Ssr 2009 Part I Icomplete All As Specified And Directed. Note - The Cast Of Excavation, Earth Work In Any Type Of Soils , Pcc 1:3:6 Type C-1 As In Foundation And Loop Type Insulators Of Required Size Shall Deemed To Included In Rate Quoted By The Tenderer. 22 M&L For Galvanised Stay Strand 7 / 4 Mm Complete All As Specified And Directed. 23 S&F In Replacement Loop Type Insulator Large Size With Overall Demensions 140 Mm Clearance Of Hole 25.5 Mm Complete All As Specified And As Directed. 24 M&L For Repair Of Led Street Light / Flood Light Of Capacity 45 Watt To 70 Watts Including Replacement Of Unserviceble / Burnt Drivers, Ac / Dc Converters Of Suitable Capacity, Power Protector, Rectifier, Mosfet, Condenser, Transformers, Diods, Capacitors, Led Bulbs , Resistors, Relays, Control Chips, Connectors, Soldering Of Connections As Per Requirement, Replacement Of Connecting Cables, Testing And Commissioning Including Dismantling From Existing Pole And Refixing The Same Place . The Rate Includes The Rate Of Spares / Tools Required For Repair Of Lights. 25 M&L For Repair Of Led Street Light / Flood Light Of Capacity 75 Watt To 120 Watts Including Replacement Of Unserviceble / Burnt Drivers, Ac / Dc Converters Of Suitable Capacity, Power Protector, Rectifier, Mosfet, Condenser, Transformers, Diods, Capacitors, Led Bulbs , Resistors, Relays, Control Chips, Connectors, Soldering Of Connections As Per Requirement, Replacement Of Connecting Cables, Testing And Commissioning Including Dismantling From Existing Pole And Refixing The Same Place . The Rate Includes The Rate Of Spares / Tools Required For Repair Of Lights. 26 Supply & Erection Prestreessed Concrete Pole 9 Mtr Long , 102 Mm X 172 Mm At Top And 102 Mm X 279 Mm At Bottom Class 10 And Including Making Strip Alternately In White And Black Colour Of 30 Cms Wide ( Total 05 Nos Strips ) And Numbering The Poles With 2 Height Letters In Synthetic Enamel Paint Tint As Directed Complete All As Specified And Directed.Make: Concrete Udyog Jhansi / M / S Hindustan Pre Stressed Concrete Structure Faridabad / M / S Mohan Concrete Udyog Lucknow 27 M&L For Painting Of Steel Tubuler 9 Mtr Poles Any Type Complete Incl Flat Iron Clamps, D Clamps, Stay Clamps, Earth Wire Clamps, Bracing, Cross Arm With Two Coat Aluminium Paint Including Prepration Old Painted Surface Marking With Alternate White And Red Strips 30 Cm Height 5 Nos Strips With Two Coat Of Synthetic Enamel Paint Andalso Including Numbering Of Poles With White Paint Are Located On Different Locations In Lt Over Head Lines Complete All As Specified And Directed.. Ici Paint ( Dulux Gloss ) , Asian Paint ( Apcolite ) , Shalimar Paints ( Superlac Hi Gloss ) , Goodlass Nerolac Paints ( Nerolac ) , Jenson & Nicholson Paints Ltd ( Brolac ) , Berger Paints ( Luxol Hi Gloss ) , Nerolac ( Nerolac Full Gloss ) 28 M & L For Prepration Of Old Painted Steel Surfaces Of Steel Cross Arm, Bracing Supports Of 11 / 9 Mtr Pcc Poles Any Type Incl Flat Iron Clamps, D Clamps, Stay Clamps, Earth Wire Clamps, Bracing, Cross Arm And Applying Two Coats Of Aluminium Paint And Including Marking The Pole With Alternate White And Red Strips Of Size 30 Cm Wide ( Total 5 Nos Strips ) With Two Coat Of Synthetic Enamel Paint Including Numbering Of Poles As Per Existing Size Of Letter Or As Directed Etc Complete All As Specified And Directed.Ici Paint ( Dulux Gloss ) , Asian Paint ( Apcolite ) , Shalimar Paints ( Superlac Hi Gloss ) , Goodlass Nerolac Paints ( Nerolac ) , Jenson & Nicholson Paints Ltd ( Brolac ) , Berger Paints ( Luxol Hi Gloss ) , Nerolac ( Nerolac Full Gloss ) 29 Laying , Connecting , Testing & Commissioning Underground Cable, Pvc Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor Cross-Sectional Area 95 - 400 Sqmm , 3.5 Core , 1100 Volts Grade Incl Taking Down / Up Of Existing Old Unserviceable Cables From Any Location / Position ( Trench / Pole ) Complete And As Directed . Note: The Rate Includes For Connection Of Cable By Providing Copper Thimbels At Both Ends Of Cables . ( Ii ) Cables Shall Be Issued Under Schedule B For Laying 30 M&L For Cable Path Indicator Made Out Of Ms Sheet Complete Duly Embossed Lt Cable Ms Sheet Of 6 Mm Thick And 6 Cm Dia Duly Fixed By Means Of Nut Bolts Washer On Angle Iron Frame Of Size 25X25x3mm Length 75 Cm Long Size Fixed On And Including Pcc1:2:4 Block Of Size 150 X 150 X 300 Mm Depth 45 Cm Above Ground Level And 30 Cm Below Ground Level Duly Painted Two Coats Of Red Oxide And Two Coats Of Enamelled Paint Complete All As Specified And Directed. Note - Cost Of Earth Work For Installation Of Path Indicator Included In The Quoted Rate. 31 M&L For Replacement Of Aluminum Bas Bar Of Differnet Sizes At Lt Panes At Various Locations Including Taking Down Of The Exisiting U / S Bus Bar After Diamantling Of Connections And Replacing New Bus Bar, Testing And Commissioning Of The Panel. The Capacity Of The Bus Bar Must Be 1.5 Times Capacity Of Incoming Mccb / Capacity As Per Installed At Site, Aluminium Busbar Chanel Insulated With Colour Coated Heat Shrinkable Sleaves And Mounted On Dmc / Epoxy Insulator .The Rate Includes Rate For Necessary Frame Work In Bus Bar, Rate Of Insulators. Nut Bolts, Connecting Copper Lugs Etc . 32 Supply, Fixing And Commissioning Of Outdoor Factory Made Weather And Vermin Proof Ms Cubical ( Cpri Approved ) Lt Feeder Panel , Fabricated With 3.15 Mm Thick Crca Sheet For Outer And 1.6 Mm Thick For Inner Shell , ( Double Door ) Duly Painted With Zinc Metal Powder Coated Paint Over A Coat Of Primer Red Oxide Including Providing 500 Amp Capacity Of Aluminium Bus Bar 04 Nos Insulated With Heat Shrinkable Sleaves And Mounted On Epoxy Insulator Of Required Size In Conical Type, Including Locking Arrangements Incl Provision Of Suitable Cable Ducts At Bottom And Control Wire Of 2.5 Sqmm Multi Stranded Copper Conductor With Adequate Size Of Lugs Be Properly Bunched. The Cubical Panel Be Fixed On Foundation In Pcc ( 1:2:4 ) Type B1 Using 20 Mm Graded Stone Aggregates As Per Existing Size And Shape . The Compartment To Accommodated To Incomer And Outgoing Mccbs, Mcbs And Measuring Equipments And Separate Door Will Cover To Each Mccb Incl Suitable Space For Accomodate The Followings :- ( A ) Incomer - Mccb 4 Pole 315 Amp 50 Hz 415V Ac With Rupturing Cap 36 Ka - 01 Nos ( B ) Outgoing - ( I ) Mccb 4 Pole 160 Amp 50Hz 415 V Ac 36 Ka - 1 Nos ( Ii ) Mccb 4 Pole 100 Amp 50Hz 415 V Ac 25 Ka - 3 Nos ( Iv ) Mcb Tpn 10 Amps 50 Hz 415 Volt 10 Ka - 01 No ( Vi ) Analoge Type Voltmeter - 01 Nos ( Vii ) Analoge Type Ammeter - 01 Nos ( Viii ) Led Type Indicator To Indicate R, Y, B Phase. Note : Necessary Connection Of Cables With Panel Required At Site Including Lugs, Nut & Bolts Etc Included In The Quoted Rate. 33 M&L Fo Replacement Of Tpn Hrc Type Rewireable Switch Fuse Unit Of 415 Volt 50 Hz Three Phase Of Capacity 16 Amp Including Ms Box Hrc Carrier, Operating Insulated Handle, Top Cover Necessary Locking Arrangemnts Etc Including Necessary Wall Mounting Fitting As Directed Including Taking Down The Existing All As Specified And Directed. Make - Indo Asian Cat Part No. Dtpn 16 Or Equivalent Approved Make 34 M&L Fo Replacement Of Tpn Hrc Type Rewireable Switch Fuse Unit Of 415 Volt 50 Hz Three Phase Of Capacity 32 Amp Including Ms Box Hrc Carrier, Operating Insulated Handle, Top Cover Necessary Locking Arrangemnts Etc Including Necessary Wall Mounting Fitting As Directed Including Taking Down The Existing All As Specified And Directed. Make - Indo Asian Cat Part No. Dtpn 32 Or Equivalent Approved Make 35 M&L Fo Replacement Of Tpn Hrc Type Rewireable Switch Fuse Unit Of 415 Volt 50 Hz Three Phase Of Capacity 63 Amp Including Ms Box Hrc Carrier, Operating Insulated Handle, Top Cover Necessary Locking Arrangemnts Etc Including Necessary Wall Mounting Fitting As Directed Including Taking Down The Existing All As Specified And Directed. Make - Indo Asian Cat Part No. Dtpn 63 Or Equivalent Approved Make 36 Excavation In Trenches N. Exc 1.5 Mtr Wide And N. Exc 1.5 Mtr Depth For Pole / Cable / Foundation Etc Including Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 37 Excavation In Trenches In Any Type Of Soil Not Exc 1.5 Mtrs Wide And Exc 1.5 Mtr In Depth For Laying Of Pipe / Cables / Poles Etc And Getting Out Complete All As Specified And As Directed. 38 Returning, Filling In, Approved Earth Including Spreading, Levelling, Watering And Well Ramming In Layers N.Exc 25 Cm Thick After Cable Are Laid And Tested Complete All As Specified And Directed. 39 Removing Excavated Material / Surplus Soil To A Distance Not Exc. 50 Mtrs & Deposited Where Directed At A Level Not Exc.1.5 Mtr Above The Ground Level Complete All As Specified & Directed. 40 Supplying And Laying Precast Concrete Cable Cover Class Lv Type -I Flat Size 250X150x40 Mm Laid Parpendicular To The Axis Of Cable In Trenches Etc Complete As Directed. Make: Make: M / S Mehatab Tiles, Rani Shopping Centre, Bhanwar, Indore, ( B ) M / S Navya Tiles, 68, Nehru Park, Sardarpur, Jodhpur- 342003 Ph. 0291-2650094, 2627963 ( C ) Sap Pavers Jodhpur ( D ) Sagar Tiles Saharanpur ( E ) Star Tiles & Industries, Rama Devi, Kanpur 41 Supply And Laying Dry River Sand For Cable Cushioning In Trenches To Required Width At Bottom And Top Of Cable Incl Spreading, Levelling, Watering And Consiolidation Complete All As Specified And Directed. 42 M&L For Pcc 1:4:8 Type D-2 ( Using 40Mm Graded Stone Aggregates ) As In Foundation Filling And Mass Concrete For Poles All As Specified And Directed . 43 M&L For Pcc 1:3:6 Type C-2 ( Using 40Mm Graded Stone Aggregates ) As In Foundation Filling And Mass Concrete Including Providing Necessary Form Work For Poles All As Specified And Directed. 44 M&L For Pcc 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregates ) As In Coping Ofpole Etc Including Providing Necessary Form Work All As Specified And Directed.