| 1 | 1 | AMC of Window/split/cassette/ductable split /packaged Acs - Comprehensive annual maintenance charges for the Window, split, package, ductable, cassette model air conditioners of following capacity including replacement with new compressors and all spares of the machines like indoor units, fan motors and blades, condensers, remote controllers, control wirings and terminal blocks & cover, vacuumising, pressure testing and gas filling if necessary during maintenance.(Machines details and locations as per Annexure) | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | 0.8/1.0/1.5/2.0 TR | BI01010001010000000000000515BI0100001113 | 2694 | Nos |
|---|
| 3 | 1.02 | 3/4/5.0/5.5 TR | BI01010001010000000000000515BI0100001114 | 165 | Nos |
|---|
| 4 | 1.03 | 7.5/8.3/8.5/11 TR | BI01010001010000000000000515BI0100001115 | 50 | Nos |
|---|
| 5 | 1.04 | 16.5 TR | BI01010001010000000000000515BI0100001116 | 10 | Nos |
|---|
| 6 | 2 | AMC of Kitchen Exhaust System/Toilet ventilation systems - Non Comprehensive Maintenance of Kitchen exhaust system at roof top of the building of various capacities.This will include routine servicing/ regular maintenance, filter cleaning, preventive mainteanance of equipments and breakdown repairs as and when occurred, ensuring that system does not remain out of service for a period not less than 4 hours in case of major breakdowns and one hour in case of minor breakdowns due to any unforeseen breakdown. The rate shall include for consumables including belts required(2 Belts per contract can be considered) for satisfactory maintanace of the installation. In case of replacement of spares required for other than belts,oiling and greese will be paid extra. | BI01010001010000000000000515BI0100001117 | | |
|---|
| 7 | 2.01 | Kitchen Exhaust System and fresh air system | BI01010001010000000000000515BI0100001118 | 24 | Nos |
|---|
| 8 | 2.02 | Toilet ventilation System | BI01010001010000000000000515BI0100001119 | 10 | Nos |
|---|
| 9 | 3 | Charges for removing the following rating /model air conditioners from the existing position including transport and safely handed over to store. | BI01010001010000000000000515BI0100001120 | | |
|---|
| 10 | 3.01 | Upto 2.0 TR window model Acs | BI01010001010000000000000515BI0100001121 | 30 | Nos |
|---|
| 11 | 3.02 | Upto 2.0 TR split model Acs(both indoor & Outdoor unit) | BI01010001010000000000000515BI0100001122 | 75 | Nos |
|---|
| 12 | 3.03 | Upto 8.5 TR ductable split/Packaged Acs(both indoor& Outdoor unit) | BI01010001010000000000000515BI0100001123 | 10 | Nos |
|---|
| 13 | 4 | Installation charges for the following rating split/ductable split/packaged and cassette type air conditioners from one position to other position including the pump down, nitrogen pressure testing, vaccumising and refilling of gas and making the machine in good working condition. (ACs will be supplied from our stores at free of cost. The contractor should arrange for transport from stores to respective locations. | BI01010001010000000000000515BI0100001125 | | |
|---|
| 14 | 4.01 | Upto 2.0 TR window model Acs | BI01010001010000000000000515BI0100001126 | 10 | Nos |
|---|
| 15 | 4.02 | Upto 2.0 TR split model Acs(both indoor & Outdoor unit) | BI01010001010000000000000515BI0100001127 | 60 | Nos |
|---|
| 16 | 4.03 | Upto 8.5 TR ductable split/Packaged Acs(both indoor& Outdoor unit) | BI01010001010000000000000515BI0100001128 | 9 | Nos |
|---|
| 17 | 5 | Gas charging for 1.5TR/2.0 TR compressor including pressure holding and leak testing. | BI01010001010000000000000515BI0100001129 | 60 | Nos |
|---|
| 18 | 6 | Gas charging for ductable/packaged type ACs including pressure holding and leak testing. | BI01010001010000000000000515BI0100001130 | 75 | Kg |
|---|
| 19 | 7 | Refrigerant copper piping(Suction & discharge) for split ductable split and cassette type air conditioners upto 3.0 TR. | BI01010001010000000000000515BI0100001131 | 200 | Metre |
|---|
| 20 | 8 | Refrigerant Hard drawn copper piping(Suction & discharge) for ductable split /packaged type air conditioners upto 8.5 TR. | BI01010001010000000000000515BI0100001132 | 150 | Metre |
|---|
| 21 | 9 | Thermal insulation for copper pipes using suitable foam insulation/Nitrile rubber insulation. (Necessary scafolding/ladder to be provided by the contractor). | BI01010001010000000000000515BI0100001133 | 300 | Metre |
|---|
| 22 | 10 | Supplying & replacement of condensing/evoporator coil with copper tube with aluminium fins in place of aluminium tube with aluminium fins of the following Acs. | BI01010001010000000000000515BI0100001134 | | |
|---|
| 23 | 10.01 | Upto 2.0 TR window AC/Split Acs | BI01010001010000000000000515BI0100001135 | 15 | Nos |
|---|
| 24 | 11 | Supply and fixing of following accessories while attending shifting the Acs from one location to other location/not covered under the AMC/warranty. | BI01010001010000000000000515BI0100001136 | | |
|---|
| 25 | 11.01 | 45/50 MFD capacitor | BI01010001010000000000000515BI0100001137 | 10 | Nos |
|---|
| 26 | 11.02 | Reconditioning of Outdoor fan motor suitable for split Acs upto 2.0TR | BI01010001010000000000000515BI0100001138 | 6 | Nos |
|---|
| 27 | 11.03 | Reconditioning Indoor fan motor suitable for split Acs upto 2.0TR | BI01010001010000000000000515BI0100001139 | 6 | Nos |
|---|
| 28 | 11.04 | 25 mm water line drain pipe | BI01010001010000000000000515BI0100001140 | 300 | Nos |
|---|
| 29 | 11.05 | 38/40 mm water line drain pipe | BI01010001010000000000000515BI0100001141 | 100 | Kg |
|---|
| 30 | 11.06 | 50mm dia water line drain pipe | BI01010001010000000000000515BI0100001142 | 50 | Metre |
|---|
| 31 | 11.07 | 3 core 2.5 sq.mm copper Chord wire | BI01010001010000000000000515BI0100001143 | 100 | Metre |
|---|
| 32 | 11.08 | out door fan blade | BI01010001010000000000000515BI0100001144 | 6 | Metre |
|---|
| 33 | 11.09 | Mounting angle for outdoor AC unit | BI01010001010000000000000515BI0100001145 | 25 | Metre |
|---|
| 34 | 11.1 | PCB serving for Acs upto 2.0 TR | BI01010001010000000000000515BI0100001146 | 20 | Metre |
|---|
| 35 | 11.11 | Strainer capilliary tube | BI01010001010000000000000515BI0100001147 | 25 | Nos |
|---|
| 36 | 11.12 | Fan capacitor | BI01010001010000000000000515BI0100001148 | 20 | Nos |
|---|
| 37 | 12 | Non comprehensive Annual maintenance contract of Flat plate Collector Solar Water Heating HTF based System with water tank made out of stainless steel confirming to SS 304 insulated with PU foam. The 500 LPD with 4 collectors and 1000 LPD with 8 nos of collectors. The out flow temperature is an average of 60°C. Collectors as per BIS and approved as per MNRE specifications. Collector equipped with anti-condensation system and as per the enclosed specfication vide Annexure A\n\n\n | BI01010001010000000000000515BI0100001149 | | |
|---|
| 38 | 12.01 | 100 LPD SWH System | BI01010001010000000000000515BI0100001150 | 1 | Nos |
|---|
| 39 | 12.02 | 500 LPD SWH system | BI01010001010000000000000515BI0100001151 | 60 | Nos |
|---|
| 40 | 12.03 | 1000 LPD SWH system | BI01010001010000000000000515BI0100001152 | 57 | Nos |
|---|
| 41 | 13 | Supply & repacement following accessories in the existing solar water system. | BI01010001010000000000000515BI0100001153 | | |
|---|
| 42 | 13.01 | 2000w heating element with thermostat | BI01010001010000000000000515BI0100001154 | 50 | Nos |
|---|
| 43 | 13.02 | Make up tank of 2 litres capacity made up SS 304 to suit the existing system | BI01010001010000000000000515BI0100001155 | 12 | Nos |
|---|
| 44 | 13.03 | Glass for HTF based solar collector | BI01010001010000000000000515BI0100001156 | 12 | Nos |
|---|
| 45 | 14 | Charges for insulating the pipe of 40/50mm dia with rock wool/PUF covered with aluminium cladding | BI01010001010000000000000515BI0100001157 | 300 | Metre |
|---|