Rate Contract Of Electrical Items To Kidwai Memorial Institute Of Oncology, Bangalore 1. Supplying Of Extension Electrical Boards With Teak Wooden Boxes With Pvc Plate Of Size 12”X9” One 16 Amps Socket And 32 Amps Flush Type Dp , 6 Amps 3 No,S Of Sockets And 6 Amps Switches( 3No,S) With 1.5 Sqmm 3 Core Copper Cable, 2. Supplying Of Extension Electrical Boards With Teak Wooden Boxes With Pvc Plate Of Size “10X7” One 16 Amps Socket And 32 Amps Flush Type Dp , 6 Amps 4 No,S Of Sockets And 6 Amps Switches 4 No,S With 1.5 Sqmm 3 Core Copper Cable, 3. Supplying 4 Mm Thick Plastic Sheet With Necessary Nitches For Fixing Switches, Regulators Etc.. And Fixing On Existing Wooden Or Metal Box Using Nf Screws Pg 17 Item 3.9, 4. Point Wiring Using Copper Wire With Switch : Supplying And Wiring Adopting Loop System In Existing Pvc Conduit /Casing Capping Using Copper Pvc Insulated Multistrand 2X 1.5 Sqmm Copper Wire With A 6 Amps Flush Type Sp Control Switch Shall Be Fixed On The Existing Plastic Sheet /Gang Box ,The Other End Of The Wires Shall Be Terminated With Sufficient Loose Length In A Wood /Pvc Round Block Complete For Each Outlet Pg 5 Item 2.1 2.1.2 2.1.2 Medium Point Above 3 Mtr Upto 6 Mtr From Tapping Point To Outlet Via Switch, 5. Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8.1 20 Mm, 6. Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8.2 25 Mm, 7. Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8. 3 32 Mm, 8. Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8. 4 38 Mm, 9. Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8. 5 50 Mm, 10. Supplying And Fixing Of Pvc Casing And Capping On The Wall Or Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc 50X100 Mm Industrial Type, 11. Supplying And Fixing Of S” Hook Made Out Of 14,Mm Dia, 12. Providing Open Conduit System Supplying And Drawing Heavy Gauze Pvc Conduit Pipes25 Mm Dia 2 Mmthick Conforming To Is 2509 With Suitable Size Bends , Junction Boxes, Adhesive Paste Etc.., 13. Providing Open Conduit System Supplying And Drawing Heavy Gauze Pvc Conduit Pipes32 Mm Dia 2.5 Mmthick Conforming To Is 2509 With Suitable Size Bends , Junction Boxes, Adhesive Paste Etc.., 14. Providing Open Conduit System Supplying And Drawing Heavy Gauze Pvc Conduit Pipes40 Mm Dia 2.5 Mmthick Conforming To Is 2509 With Suitable Size Bends , Junction Boxes, Adhesive Paste Etc.., 15. Supplying And Drawing Heavy Duty 2 Inch Pvc Pipe Thickness 3Mm, 16. Supplying And Drawing Heavy Duty 2.5 Inch Pvc Pipe Thickness 3.25Mm, 17. Supplying And Drawing Heavy Duty 2.5 Inch Pvc Pipe Thickness 3.5Mm, 18. Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe 19/20 Mm Dia 2 Mm Thick, 19. Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe 25 Mm Dia 2 Mm Thick, 20. Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe 32 Mm Dia 2.5 Mm Thick, 21. Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe 40Mm Dia 2.5 Mm Thick, 22. Providing Concealed System Supplying Heavy Gauze Pvc Conduit Pipe 19/20Mm Dia 2 Mm Thick Conforming To Is 2509 With Suitable Size Bends , Metal / Pvc Junction Boxes , Adhesive Paste Etc.. And Renning Before Concreting The Slab. The Conduit Shall Be Tied To The Reinforcement Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures , Run With 18 Swg Gi Fish Wire Wherever Necessary, 23. Providing Concealed System Supplying Heavy Gauze Pvc Conduit Pipe 25Mm Dia 2 Mm Thick Conforming To Is 2509 With Suitable Size Bends , Metal / Pvc Junction Boxes , Adhesive Paste Etc.. And Renning Before Concreting The Slab. The Conduit Shall Be Tied To The Reinforcement Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures , Run With 18 Swg Gi Fish Wire Wherever Necessary, 24. Providing Concealed System Supplying Heavy Gauze Pvc Conduit Pipe 32Mm Dia 2.5 Mm Thick Conforming To Is 2509 With Suitable Size Bends , Metal / Pvc Junction Boxes , Adhesive Paste Etc.. And Renning Before Concreting The Slab. The Conduit Shall Be Tied To The Reinforcement Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures , Run With 18 Swg Gi Fish Wire Wherever Necessary, 25. Providing Concealed System Supplying Heavy Gauze Pvc Conduit Pipe 40Mm Dia 2.5 Mm Thick Conforming To Is 2509 With Suitable Size Bends , Metal / Pvc Junction Boxes , Adhesive Paste Etc.. And Renning Before Concreting The Slab. The Conduit Shall Be Tied To The Reinforcement Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures , Run With 18 Swg Gi Fish Wire Wherever Necessary, 26. Supply And Fixing /Replacing Of 6/16/32 Amps Electrical Accessories On Existing Switch Board Pg 18 Item 3.15 Group A 3.15.1 6 Amps Sp Switch, 27. Supply And Fixing /Replacing Of 6/16/32 Amps Electrical Accessories On Existing Switch Board Pg 18 Item 3.15 Group A 3.15.3 6 Amps 3 Way 5 Pin Socket, 28. Supply And Fixing /Replacing Of 6/16/32 Amps Electrical Accessories On Existing Switch Board Pg 18 Item 3.15 Group A 3.15.10 16 Amps 3 Way 5 Pin Socket, 29. Supply And Fixing Of Bakelite D.P/Socket/Switch With /Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg 15 Item 3.3 Group A 3.3.1 32 Amps Flush/Projected Type Dp Switc, 30. Supply And Fixing Of Bakelite D.P/Socket/Switch With /Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg 15 Item 3.3Group A 3.3.5 Electronic Stepped Regulator, 31. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.1 1 Sqmm, 32. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.2 1.5 Sqmm, 33. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.3 2.5 Sqmm, 34. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.4 4 Sqmm, 35. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.5 6 Sqmm, 36. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.6 10 Sqmm, 37. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.7 16 Sqmm, 38. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 25 Sqmm, 39. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 50 Sqmm, 40. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.7 100 Sqmm, 41. Wiring For Lighting /Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2. 2.5.7 150 Sqmm, 42. Supplying Capacitor Type Ceiling Fan Complete With Down Rod Blades,Shackle,Canopies Etc… For Operation On 230 Volts 50 Cycles.Single Phase Ac Supply Conforming To Iss-374-1979 And With Double Ball Bearing System And As Per Technical Data Approved Pg 78 Sl No 9.3 Sl No 9.3.1 48” Sweep(1200Mm) Sl No 9.3.1.1 Regular Model, 43. Fixing A Ceiling Fan /Wall Monting Fan Of All Capacities And All Types With Necessary Clamps And S” Hook Made Out Of 15Mm Dia Ms Rod With 5 Amps Ceiling Rose Of Approved Quality With Necessary Length Of 23/0.0076” Inch Pvc Insulated Twin Twisted Wire Od Approved Quality . Mounted On A Suitable Size Wooden Board And Wired Pg 109 Item 17.9, 44. Fabricating Supplying And Mounting Ms Box Made Out … Swg Suitable For Floor/Wall Mounting , Fully Weather Proof With Provision For Better Heat Dissipation , Provided With Hinged Front Cover , Equipped With Tamper Proof Locking Arrangements , With Suitable Size Clamps With Necessary Cable Entry Pipe With Gland And Box Should Be Finished With 2 Coats Of Red Oxide Primer Paint And Finally Finished With Approved Colour Enameled Metal Paint Etc.. Complete Pg 49 Item 6.40, 6.40.2 6.40.2 16 Swg, 45. Supplying And Fixing Moulded Circuit Breaker (Mccb) Over Existing Wood Panel Board Using Necessary Screws,Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic/Micrpprocessed Release And Earth Fault As Per (Is-13947 Pg 46 Item 6.13 Four Pole 6.13.8 Four Pole 6.13.6 100 Amps 25 Ka, 46. Supplying And Fixing Moulded Circuit Breaker (Mccb) Over Existing Wood Panel Board Using Necessary Screws,Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic/Micrpprocessed Release And Earth Fault As Per (Is-13947 Pg 46 Item 6.13 Four Pole 6.13.8 Four Pole 6.13.7 125-160 Amps 25 Ka, 47. Supplying And Fixing Moulded Circuit Breaker (Mccb) Over Existing Wood Panel Board Using Necessary Screws,Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic/Micrpprocessed Release And Earth Fault As Per (Is-13947 Pg 46 Item 6.13 Four Pole 6.13.8 Four Pole 6.13.8 200 Amps 35 Ka, 48. Supplying And Fixing Moulded Circuit Breaker (Mccb) Over Existing Wood Panel Board Using Necessary Screws,Bolts, Nuts And Wiring Complete.Protection Of Over Load And Short Circuit With Thermal Magnetic/Micrpprocessed Release And Earth Fault As Per (Is-13947 Pg 46 Item 6.13 Four Pole 6.13.8 Four Pole 6.13.9 250 Amps 35 Ka, 49. Supplying And Fixing Moulded Circuit Breaker (Mccb) Over Existing Wood Panel Board Using Necessary Screws,Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic/Micrpprocessed Release And Earth Fault As Per (Is-13947 Pg 46 Item 6.13 Four Pole 6.13.8 Four Pole 6.13.10 320-400 Amps 50 Ka, 50. Supplying And Fixing Moulded Circuit Breaker (Mccb) Over Existing Wood Panel Board Using Necessary Screws,Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic/Micrpprocessed Release And Earth Fault As Per (Is-13947 Pg 46 Item 6.13 Four Pole 6.13.8 Four Pole 6.13.10 630 Amps 50 Ka, 51. Supplying And Fixing Moulded Circuit Breaker (Mccb) Over Existing Wood Panel Board Using Necessary Screws,Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic/Micrpprocessed Release And Earth Fault As Per (Is-13947 Pg 46 Item 6.13 Four Pole 6.13.8 Four Pole 6.13.10 700-800 Amps 50 Ka, 52. Supplying And Fixing Of Air Circuit Breakers 4Pole( Acb.S) Manual Operable Make :L&T, C&S . Schenider Or Abb, 53. Supplying And Fixing Of Air Circuit Breakers 3Pole( Acb.S) Manual Operable Make :L&T, C&S , Schenider Or Abb, 54. Supplying And Fixing Of 1 Od For Rmu( Vcb,S) 630 Amps, 55. Supplying And Fixing Of 1 Vl For Rmu, 630 Amps, 56. Cleaning Of Ht Yard By Removing The Vegetation, 57. Providing Painting For Ht Substation( Alluminium Painting Including All Labour Charges, 58. Providing Painting For 500 Kva Transformers, 59. Providing Painting Of Lt Distribution Boards( Spray Painting), 60. Filtering Of Oil In The Transformer At The Transformer Centre By Hot Process Using Steam Line Filter “ Such Time The Dielectric Strength Of The Oil In The Transformer Conforms To Isi Specifications (Test Certificates To Produced), 61. Supplying And Fixing Of 19Mm Dia 2Mm Wall Thickness 15 Kv Class Alkathine Pipe To Bus Bar Leads Etc.. At Substation, 62. Supplying And Fixing Of 25Mm Dia 2Mm Wall Thickness 15 Kv Class Alkathine Pipe To Bus Bar Leads Etc.. At Substation, 63. Supplying And Topping Of Oil For Di-Electric Strength (Bdv) Acidity, 64. Supplying And Topping –Up Of New Transil Oil, 65. Supplying And Filling Fresh Silica Gel To The Breathe Of The Transformers, 66. Providing Megger Test For The Earth Pits At The Electrical Substation, 67. Supplying And Fixing Of Nuts And Bolts For The Earth Pits At The Electrical Substation And Other Areas, 68. Supplying And Pouring Salt For Earth Pits 25 Kg Bags, 69. Supplying And Pouring The Charcoal 25 Kgs Bags, 70. Re- Construction Of Earth Pit Chambers , Labelling And Covering The Earth Pits With Cast Iron Cover 400X400x400 Mm, 71. Providing Calibration Services For All The Energy Metres /Ct,S Of Dg Sets, 72. Providing Megger Test Results For The Damaged Cables To Detect The Damagof Lt Cable, 73. Providing Megger Test Results For The Damaged Cables To Detect The Damage Of Ht Ug Cable, 74. Submission Of Compliance Report To Electrical Inspectorate Against The Observations Made By The Electrical Inspectorate( Except Statutory Fees), 75. Providing Re- Winding For Copper Wound Transformer Including Releasing And Re-Fixing With All Lead And Lift Including Providing Crane Services And Providing Mgger Test Etc.., 76. Supplying And Installtion Of 10 Hp Kirloskar Make Monoblock Water Supply Motors, 77. Supplying And Installtion Of 5 Hp Kirloskar Make Monoblock Water Supply Motors, 78. Supplying Of 1 Hp Single Phase Motor Of Kirloskar Make, 79. Supplying Of Non Return Vales For Water Supply 50 Mm, 80. Supplying Of Foot Valve Set For 1 Hp Chiller Pump, 81. Supplying Of 5 Hp Submersible Pump Motrs( 2No,S) Kirloskar Make/ Atlanta/ Texmo With Adelivery Point Is About 30 Mtrs Height For Dharmasahala Pump House Including Supplying And Fixing Automatic Starter Panel With Selctor Switch Type Change Over So That One Motor Shall Operate At A Time Including Supplying And Drawing 2 .5 Inch Cpvc Pipe , Automatic Starter Control Panel , Mccb 100 Amps And Mcb 3 Ploe 32 Amps And Contactor 40 Amps And Plumbimg Works Incuding Supplying And Fixing Of Non Return Vales 4 No,S Of 50Mm And Gate Valves Of Heavy Duty 2 No,S) Of Required Size Etc.. With A Automatic Water Controller Facility By Supplying And Drawing Ofc Cable Of About 175 For Providing Water Supply To Ot Block, 82. Supplying Of 10 Hp Submersible Pump Motrs( 2No,S) Kirloskar Make/ Atlanta/ Texmo With Adelivery Point Is About 30 Mtrs Height For Dharmasahala Pump House Including Supplying And Fixing Automatic Starter Panel With Selctor Switch Type Change Over So That One Motor Shall Operate At A Time Including Supplying And Drawing 2 .5 Inch Cpvc Pipe , Automatic Starter Control Panel , Mccb 100 Amps And Mcb 3 Ploe 32 Amps And Contactor 40 Amps And Plumbimg Works Incuding Supplying And Fixing Of Non Return Vales 4 No,S Of 65Mm And Gate Valves Of Heavy Duty 2 No,S) Of Required Size Etc.., 83. Supplying Fixing And Wiring Earth Electrode For Grounding Of Lifts Transformers ,Dg Sets Etc.. Using 40Mm Dia 2.9 Mm Thick 2.5 Mtr Long Gi Pipe With Gi Funnel With Mesh And Suitable Size Reducer Fixed On The Top Of The Earth Electrode .The Funnel Should Be Enclosed In A Cc Chamber Of 400X 400X 400Mm With A Cast Iron Cover .The Earth Electrode Shall Have Staggered Holes Of 12Mm Dia And The Electrode Should Be Covered 150Mm Alround With Alternate Layers Of Salt And Charcoal From The Bottom Of The Cc Chamber.The Connection From The Electrode Is To Be Established Through Gi Strip Using Gi Bolts And Nuts Pg 55 Item 7.2, 84. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.1 25 X3mm, 85. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.2 25 X6mm, 86. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.3 40 X6mm, 87. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.5 600X600x3mm Gi Plate, 88. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.3.6 25 X3mm, 89. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.3.7 25 X6mm, 90. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.933.8 40 X6mm, 91. Supplying And Running Of Gi/Copper Strips For Grounding Connections,Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.3.10 600X600x3mm Plate, 92. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.1 2 Core 10 Sqmm, 93. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.2 4 Core 10 Sqmm, 94. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.3 2 Core 16 Sqmm, 95. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.4 4 Core 16 Sqmm, 96. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.5 3.5 Core 25 Sqmm, 97. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.6 3.5 Core 35 Sqmm, 98. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.7 3.5 Core 50 Sqmm, 99. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group -A Pg 55 & 56 Item 7.4 7.4.8 3.5 Core 70 Sqmm, 100. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 55 & 56 Item 7.4 7.4.9 3.5 Core 95 Sqmm, 101. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 55 & 56 Item 7.4 7.4.10 3.5 Core 120 Sqmm, 102. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 55 & 56 Item 7.4 7.4.11 3.5 Core 150 Sqmm, 103. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 55 & 56 Item 7.4 7.4.9 3.5 Core 185 Sqmm, 104. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 55 & 56 Item 7.4 7.4.10 3.5 Core 240 Sqmm, 105. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 55 & 56 Item 7.4 7.4.11 3.5 Core 300 Sqmm, 106. Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated,Extruded Inner Sheathed Sheathed,Galvanised ,Strips (Except 2Cx10 Sqmm Wire Armoured) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 55 & 56 Item 7.4 7.4.12 3.5 Core 400 Sqmm, 107. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.1 2 Core 1.5 Sqmm, 108. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.2 3 Core 1.5 Sqmm, 109. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.3 4 Core 1.5 Sqmm, 110. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.4 6 Core 1.5 Sqmm, 111. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.5 8 Core 1.5 Sqmm, 112. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.6 10 Core 1.5 Sqmm, 113. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.7 2 Core 2.5 Sqmm, 114. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.8 3Core 2.5 Sqmm, 115. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.9 4Core 2.5 Sqmm, 116. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.10 6Core 2.5 Sqmm, 117. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.11 8Core 2.5 Sqmm, 118. Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.8.12 10 Core 2.5 Sqmm, 119. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required Pg 61 Item 7.8In Existing Trench/Duct7.8.1 6 Sqmm To 16 Sqmm, 120. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required Pg 61 Item 7.8In Existing Trench/Duct 7.8.2 25 Sqmm To 75 Sqmm, 121. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required Pg 61 Item 7.8In Existing Trench/Duct 7.8.3 95 Sqmm To 150 Sqmm, 122. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required Pg 61 Item 7.8In Existing Trench/Duct 7.8.4 185 Sqmm To 240 Sqmm, 123. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required Pg 61 Item 7.8In Existing Trench/Duct 7.8.5 300 Sqmm To 400 Sqmm, 124. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe/Stone Ware Pipe /On Wall/On Pole As Required Pg 61 Item 5 7.8, 7.8.2 On Wall/Structure 7.8.6 6 Sqmm To 16 Sqmm, 125. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe/Stone Ware Pipe /On Wall/On Pole As Required Pg 61 Item 5 7.8, 7.8.2 On Wall/Structure 7.8.7 25 Sqmm To 75Sqmm, 126. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe/Stone Ware Pipe /On Wall/On Pole As Required Pg 61 Item 5 7.8, 7.8.2 On Wall/Structure 7.8.8 95 Sqmm To 150Sqmm, 127. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe/Stone Ware Pipe /On Wall/On Pole As Required Pg 61 Item 5 7.8, 7.8.2 On Wall/Structure 7.8.9 185 Sqmm To 240 Sqmm, 128. Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe/Stone Ware Pipe /On Wall/On Pole As Required Pg 61 Item 5 7.8, 7.8.2 On Wall/Structure 7.8.10 300 Sqmm To 400 Sqmm, 129. Earth Work Excavation For Cable Trench Of 0.5 To 0.75 Mtr Width And Depth Upto 1 Mtr Including Trial Pits , Depositing On Bank Upto A Lead 50 Mtrs, Supplying And Displaying Necessary Danger Boards And Lighting, Using Sight Rails And Sign Boards At Every 100 Mtrs Wherever Necessary As Directed( Bescom Sr) In Ordinary Soil, 130. Earth Work Excavation For Cable Trench Of 0.5 To 0.75 Mtr Width And Depth Upto 1 Mtr Including Trial Pits , Depositing On Bank Upto A Lead 50 Mtrs, Supplying And Displaying Necessary Danger Boards And Lighting, Using Sight Rails And Sign Boards At Every 100 Mtrs Wherever Necessary As Directed( Bescom Sr) In Hard Soil, 131. Earth Work Excavation For Cable Trench Of 0.5 To 0.75 Mtr Width And Depth Upto 1 Mtr Including Trial Pits , Depositing On Bank Upto A Lead 50 Mtrs, Supplying And Displaying Necessary Danger Boards And Lighting, Using Sight Rails And Sign Boards At Every 100 Mtrs Wherever Necessary As Directed( Bescom Sr) In Hard Rock/ Latterite Rock, Latterite Soil, 132. Refilling The Trenches With Selected Available Earth From The Trenchexcavation Including Watering, Consolidation In Layers Of 15Cmthickness Including Deposition Of Surplus Earth With Lead Of 200 Mtrs( Bescom Sr), 133. Cutting The Road Surface For Cable Trenches And Disposing Of The Excavated Earth, As Directed Including Barricading, Danger Lighting Then Refilling The Cable Trenches( Bescom Sr) Macadam Road, 134. Cutting The Road Surface For Cable Trenches And Disposing Of The Excavated Earth, As Directed Including Barricading, Danger Lighting Then Refilling The Cable Trenches( Bescom Sr) Tar Road, 135. Cutting The Road Surface For Cable Trenches And Disposing Of The Excavated Earth, As Directed Including Barricading, Danger Lighting Then Refilling The Cable Trenches( Bescom Sr)Cement Concrete Road, 136. Providing And Laying In Position Plain Cement Concrete Of Mix 1:4:8 With Opc Cement @ 180Kgs, With 40Mm And Down Size Graded Metal Coarse Aggregate @0.85Cum And Fine Aggregates @0.57Cum Machine Mixed, Concrete Laid In Layers Not Exceeding 15Cms. Thick Well Compacted In Foundation Including Cost Of All Materials, Labour Hom Of Machinery Curing Complete As Per Specifications. (Page No. 13, Item No. 4.3)., 137. Ksrb 4.2.8: Providing And Laying In Position Reinforced Cement Concrete Of Design Mix M-20 With Opc Cement @ 320Kgs, With 20Mm And Down Size Graded Granite Metal Coarse Aggregates @ 0.69Cum And Fine Aggregates @ 0.46Cum, With Superplastisiser @ 3Lts Confirming To Is9103-1999 Reaffired-2008, Machine Mixed, Concrete Laid In Layers Not Exceeding 15Cms Thick, Vibrated For R.C.C. Beams, Columns Of All Sizes In Foundation Plinth And Superstructure Ground Floor Level For Roof Slabs, Staircase, Lintles, Columns, Including Cost Of All Materials, Labour, Hom Of Machinery, Curing, Complete As Per Specification. Specification No. Kbs 4.1, 4.6 Page No.14/ Item No. 4.13/ Pwd Sr 2018-19., 138. Painting Two Coats After Filling The Surface With Synthetic Enamel Paint In Approved Shades On New Plastered Concrete Surfaces With Materials, Labour Complete As Per Specifications (Page No. 180, Item No. 24.1), 139. Ksrrb 500-6: Providing And Applying Primer Coat With Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.60 Kg/Sqm Using Mechanical Means Complete As Per Specifications. Morth Specification No. 502 Page No. 158, Item No. 21.6), 140. Ksrrb M500-17: Providing And Laying Dense Graded Bituminous Macadam Using Crusheder Hour Using Crushed Aggregates Of Specified Grading, Premixed With Vg30 Grade Bituminous Binder And Transporting The Hot Mix To Work Site, Laying To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction In All Respects Complete In All Respects As Per Specifications. Clause 505 Of Morth V Revision Using 120Tph Capacity Asphalt Batch Mix Plant With Sensor Paver Gr-Ll (50Mm To 75Mm) With 4.5% Vg-30 Bitumen Page No. 160/ Item No. 21.17.2/ Pwd Sr 2018-19, 141. Providing And Applying Tack Coat Using 80/100 Grade Bitumen(Vg10) On The Prepared Black Topped Surfaces At 2.5 Kg Per 10 Sqm, Heating Bitumen In Boiler Fitted With Spray Set (Excluding Cleaning Of Road Surface) Including Cost Of All Materials, Labour, Hom Of Machineries Complete As Per Specifications (Page 158, Item No.21.7)., 142. Ksrrb M500-18: Providing And Laying Semi Dense Bituminous Concrete Using Crusheder Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder And Filler, Transporting The Hot Mix To Work Site, Laying To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specifications. Clause 508 Complete In All Respects Complete As Per Specifications. Using 40/60 Tph Capacity H.M.P With Sensor Paver Gr-Ll (25Mm To 30Mm) With 5% Vg-10 Bitumen Page No. 160/ Item No. 21.20.10/ Pwd Sr 2018-19, 143. Ksrrb M400- Wet Mix Macadam Ksrrb M400-17. Providing, Laying, Spreading And Compacting Crushed Stone Aggregates Of Granite / Trap / Basalt To Wet Mix Macadam Specifications Including Pre Mixing The Material With Water At Omc In Mechanical Mix Plant Carriage Of Mixed Method Of Tipper To Site, Laying In Uniform Layers With Paver In Sub-Base/Base Course On Well Prepared Surface And Compacting With Vibratory Roller To Achieve The Desired Density Complete As Per Specifications. Morth Specification No. 406 (P.No.155, Itm No-20.18 Pwd Sr 18-19)Ksrrb M400- Wet Mix Macadam Ksrrb M400-17. Providing, Laying, Spreading And Compacting Crushed Stone Aggregates Of Granite / Trap / Basalt To Wet Mix Macadam Specifications Including Pre Mixing The Material With Water At Omc In Mechanical Mix Plant Carriage Of Mixed Method Of Tipper To Site, Laying In Uniform Layers With Paver In Sub-Base/Base Course On Well Prepared Surface And Compacting With Vibratory Roller To Achieve The Desired Density Complete As Per Specifications. Morth Specification No. 406 (P.No.155, Itm No-20.18 Pwd Sr 18-19), 144. Spreading Of 40Mm Stone Jelly, 145. Providing Chain Link Fencing 50Mm Size Of 8 Gauge Properly Stretched Between Rectangular Poles And Fixed With Suitable Bolts & Nuts , The Free Ends Shall Be Welded To The Poles And Block Pipe At Bottom As Required Including Cost Of All Materials, Labour, Lead Anf Lifts, Cutting, Bending Wherever Necessary, Wastage And Lapping Etc.. Complete As Per The Direction Of The Enginner In Charge Of The Work Including Two Coats Of Approved Quality Paint Over One Coat Of Primer Paint, 146. Providing And Fixing M.S Block Pipe Of 38Mm Dia Of Heavy Gauge Of 14 Including Removing The Bends , Cutting The Pipes And Fixing Pipe In Between The Two Vertical Poles( Ms Rectangular Poles) And Spot Welding The Chain Link With M.S Block Pipe Including Cost Of All Matrials Wasting In Cutting, Scaffolding Wherever Necessary With All Lead And Lift As Per The Directions Of The Enginner Of The Work Etc.. Complete Including Two Coats Of Approved Quality Paint Over One Coat Of Shop Paint Pg No:262 Item No:37.4, 147. Supplying And Fixing Ms Rectangular Poles Made Out Of 2 Equal Angels Of 65C656 Mm Welde, 148. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.1 1.5 Sqmm, 149. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.2 2.5, 150. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.3 4 Sqmm, 151. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.4 6 Sqmm, 152. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.5 10 Sqmm, 153. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.6 16 Sqmm, 154. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.7 25 Sqmm Long Barrel, 155. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.8 35 Sqmm Long Barrele, 156. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.9 50 Sqmm Long Barrel, 157. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.10 70 Sqmm Long Barrel, 158. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.11 95 Sqmm Long Barrel, 159. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.12 120 Sqmm Long Barrel, 160. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.13 150 Sqmm Long Barrel, 161. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.14 185 Sqmm Long Barrel, 162. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.15 240 Sqmm Long Barrel, 163. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.15 300 Sqmm Long Barrel, 164. Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 64 Item 7.21.6, 7.21.15 400 Sqmm Long Barrel, 165. Supplying Capacitor Type Ceiling Fan Complete With Down Rod Blades,Shackle,Canopies Etc… For Operation On 230 Volts 50 Cycles.Single Phase Ac Supply Conforming To Iss-374-1979 And With Double Ball Bearing System And As Per Technical Data Approved Pg 78 Sl No 9.3 Sl No 9.3.1 48” Sweep(1200Mm) Sl No 9.3.1.1 Regular Model, 166. Supplying Capacitor Type Ceiling Fan Complete With Down Rod Blades,Shackle,Canopies Etc… For Operation On 230 Volts 50 Cycles.Single Phase Ac Supply Conforming To Iss-374-1979 And With Double Ball Bearing System And As Per Technical Data Approved Pg 78 Sl No 9.3 Sl No 9.3.2 56” Sweep(1400Mm) Sl No 9.3.1.1 Regular Model, 167. Fixing A Ceiling/Wall Mounting Fan Of All Capacities And All Types To The Existing Shook With Fan Regulator To The Existing Board Together With Supplying And Fixing A 5 Amperes Ceiling Rose ,Necessary Length Of 23 /0.0076” Inch Pvc Insulated Twin Twisted Copper Wire And Wiring Pg 109 Sl No:17.8, 168. Fixing A Ceiling/Wall Mounting Fan Of All Capacities And All Types With Necessary Clamps And “ S “ Hook Made Out Of 15Mm Dia Ms Rod , With 5 Amps Ceiling Rose Of Approved Quality With Necessary Length Of 23/ 0.0076 Inch Pvc Insulated Twin Twisted Wire Of Approved Quality. Mounted On Suitable Size And Wired Pg 109 Item 17.9, 169. Supplying Exhaust Fan Of 1440 Rpm Of 300Mm (12’) Size Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Supply Complete Pg 78 Item 9.1, 170. Supplying Exhaust Fan Of 1440 Rpm Of 300Mm (12’) Heavy Duty Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Supply Complete Pg 78 Item 9.2 9.2.1 12” Sweep(300Mm), 171. Supplying Exhaust Fan Of 1440 Rpm Of 300Mm (12’) Heavy Duty Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Supply Complete Pg 78 Item 9.2 9.2.1 15” Sweep(450Mm), 172. Fixing One Exhaust Fan After Making A Suitable Nitch In The Wall And Finishing With Cement Morter And Colouring To Match The Existing Wall Or Brackets With Bolts And Nuts And A 5 Amps Ceiling Rose With Sufficient Length Of 23 /0.0076 Inch Pvc Insulated Twin Core Wire Of Approved Make With Wire Mesh Amd Wooden Frame Pg 109 Item 17.11, 173. Fixing One Exhaust Fan In The Nitch Nitch Already Left In The Wall With Bolts And Nuts And 5 Amps Ceiling Rose With Sufficient Length Of 23/ 0.0076 Inch Pvc Insulated Twin Core Wire, 174. Supplying Of 3 Star 1 Ton Capacity Window Type Air Conditioner Confirming To Is Specification Suitable For Operation On 230 Volts , 50 Hz Ac Supply With All Accessories Pg 78 Item 9.5 9.5.1 1 Ton Capacity 3 Star Rated Copper Condenser, 175. Supplying Of 3 Star 1 Ton Capacity Window Type Air Conditioner Confirming To Is Specification Suitable For Operation On 230 Volts , 50 Hz Ac Supply With All Accessories Pg 78 Item 9.5 9.5.1 1.5 Ton Capacity 3 Star Rated Copper Condenser, 176. Supplying Of 3 Star 1 Ton Capacity Window Type Air Conditioner Confirming To Is Specification Suitable For Operation On 230 Volts , 50 Hz Ac Supply With All Accessories Pg 78 Item 9.59.5.1 1 Ton Capacity 3 Star Rated Copper Condenser, 177. Supplying Of 3 Star Rated 1 Tr Split Air Conditioner Suitable For Operation On Ac Supply Single Phase 50 Hz 230 Volts With Hermitically Sealed Compressor With Air Cooled Condenser,Motor Capacitor And Start Run Capacitors,Relay And Over Load Protector Internal Unit. With One Indoor And One Out Door Unit .The Condenser Unit Will Be Placed Outside The Room On The Terrace To Avoid The Noise Including Standard Length Of Suitable Size Copper Tubing Covered With Insulation Tube .(High Wall Chorded/Chordless) Pg 78 Item 9.6.1.1 9.6.1.1 1 Ton Capacity 3 Star Rated, 178. Supplying Of 5 Star Rated 1 Tr Split Air Conditioner Suitable For Operation On Ac Supply Single Phase 50 Hz 230 Volts With Hermitically Sealed Compressor With Air Cooled Condenser,Motor Capacitor And Start Run Capacitors,Relay And Over Load Protector Internal Unit. With One Indoor And One Out Door Unit .The Condenser Unit Will Be Placed Outside The Room On The Terrace To Avoid The Noise Including Standard Length Of Suitable Size Copper Tubing Covered With Insulation Tube .(High Wall Chorded/Chordless) Pg 78 Item 9.6.2.1 9.6.2.1 1 Ton Capacity 5 Star Rated, 179. Supplying Of 3 Star Rated 1.5 Tr Split Air Conditioner Suitable For Operation On Ac Supply Single Phase 50 Hz 230 Volts With Hermitically Sealed Compressor With Air Cooled Condenser,Motor Capacitor And Start Run Capacitors,Relay And Over Load Protector Internal Unit. With One Indoor And One Out Door Unit .The Condenser Unit Will Be Placed Outside The Room On The Terrace To Avoid The Noise Including Standard Length Of Suitable Size Copper Tubing Covered With Insulation Tube .(High Wall Chorded/Chordless) Pg 78 Item 9.6.1.1 9.6.1.2 1.5 Ton Capacity 3 Star Rated, 180. Supplying Of 5 Star Rated 1.5 Tr Split Air Conditioner Suitable For Operation On Ac Supply Single Phase 50 Hz 230 Volts With Hermitically Sealed Compressor With Air Cooled Condenser,Motor Capacitor And Start Run Capacitors,Relay And Over Load Protector Internal Unit. With One Indoor And One Out Door Unit .The Condenser Unit Will Be Placed Outside The Room On The Terrace To Avoid The Noise Including Standard Length Of Suitable Size Copper Tubing Covered With Insulation Tube .(High Wall Chorded/Chordless) Pg 78 Item 9.6.2.2 9.6.2.2 1.5 Ton Capacity 5 Star Rated, 181. Supplying Of 3 Star Rated 1.5 Tr Split Air Conditioner Suitable For Operation On Ac Supply Single Phase 50 Hz 230 Volts With Hermitically Sealed Compressor With Air Cooled Condenser,Motor Capacitor And Start Run Capacitors,Relay And Over Load Protector Internal Unit. With One Indoor And One Out Door Unit .The Condenser Unit Will Be Placed Outside The Room On The Terrace To Avoid The Noise Including Standard Length Of Suitable Size Copper Tubing Covered With Insulation Tube .(High Wall Chorded/Chordless) Pg 78 Item 9.6.1.3 9.6.1.3 2 Ton Capacity 3 Star Rated, 182. Supplying Of 5 Star Rated 2 Tr Split Air Conditioner Suitable For Operation On Ac Supply Single Phase 50 Hz 230 Volts With Hermitically Sealed Compressor With Air Cooled Condenser,Motor Capacitor And Start Run Capacitors,Relay And Over Load Protector Internal Unit. With One Indoor And One Out Door Unit .The Condenser Unit Will Be Placed Outside The Room On The Terrace To Avoid The Noise Including Standard Length Of Suitable Size Copper Tubing Covered With Insulation Tube .(High Wall Chorded/Chordless) Pg 79 Item 9.6.2.3 9.6.2.3 2 Ton Capacity 5 Star Rated, 183. Installation Charges For 1 To 2Ton Capacity Window Type Air Conditioners With 50X75 Thick Teak Wood Frame Of Suitable Size And Allied Works Complete Pg 79 Item 9.9, 184. Installation Charges For Split Type Air Conditioners With Allied Works For One Indoor And One Outdoor Unit Is To Be Mounted On Suitable Angle Iron Support Upto 3.0 Ton Split/Cassette Type A/C Pg 79 Item 9.10, 185. Supplying And Fixing Of Insulated Refrigrent Copper Tubing Of 5/8’’ And 3/8’’ With Polythene Foam Insulation 3 Core 80 Strands Copper Wiring Between Indoor And Outdoor Unit.Leak Testing Of Oil And Gas Charging For Additional Piping Length Of Tube Pg 79 Item 9.11.1, 186. Supplying And Refilling Refrigerant (F-22/F-12 )For Air Conditioning Equipment Including Labour And Nitrogen Gas For Pressure And Leak Testing Pg 80 Item 9.17, 187. Extra For Fabrication Supply And Fixing Of Standard Fabricated Using Slotted Angel/L-Angel Of Size 6Mmx50mm For Mounting Out Door/Indoor A.C.Unit/Batteries Pg 80 Item 9.20, 188. Supplying And Fixing Capacitors Of Approved Make For Window/ Split Air Conditioners Pg 80 Item 9.14.1 9.14.1 25 To 45 Mfd Running Capacitor, 189. Supplying And Fixing Capacitors Of Approved Make For Window/ Split Air Conditioners Pg 80 Item 9.14 9.14.2 80 To 200 Mfd Starting Capacitor, 190. Supplying And Installation , Testing And Commissioning Of Heavy Duty Compressor Suitable Foe Window / Split Type Ac Pg 79 Item9.12 9.12.1 1 Ton Capacity, 191. Supplying And Installation , Testing And Commissioning Of Heavy Duty Compressor Suitable Foe Window / Split Type Ac Pg 79 Item9.12 9.12.2 1.5 To 2Ton Capacity, 192. Supplying And Installation , Testing And Commissioning Of Heavy Duty Compressor Suitable Foe Window / Split Type Ac Pg 79 Item9.129.12.3 3 Ton Capacity, 193. Supplying , Errction, Testing, Commissioni9ng Of Cassette Type Split Air Conditioners Suitable For Operation On Single Phase/ Three Phase Ac Supply , Hermetically Sealed Compressor With Air Cooled Condenser Motor Start, Capacitor Run , Relay And Ober Load Protection , One Ceiling Mounted Indoor Unit And Out Door Condenser Unit Including Standard Accessories Covered With Insulation Tube Including Battery Operated Cordless Unit Pg 79 Item 9.7 9.7.1 2 Tr Cassette Single Phase, 194. Supplying , Errction, Testing, Commissioni9ng Of Cassette Type Split Air Conditioners Suitable For Operation On Single Phase/ Three Phase Ac Supply , Hermetically Sealed Compressor With Air Cooled Condenser Motor Start, Capacitor Run , Relay And Ober Load Protection , One Ceiling Mounted Indoor Unit And Out Door Condenser Unit Including Standard Accessories Covered With Insulation Tube Including Battery Operated Cordless Unit Pg 79 Item 9.7 9.7.2 3 Tr Cassette Three Phase, 195. Supplying , Errction, Testing, Commissioni9ng Of Cassette Type Split Air Conditioners Suitable For Operation On Single Phase/ Three Phase Ac Supply , Hermetically Sealed Compressor With Air Cooled Condenser Motor Start, Capacitor Run , Relay And Ober Load Protection , One Ceiling Mounted Indoor Unit And Out Door Condenser Unit Including Standard Accessories Covered With Insulation Tube Including Battery Operated Cordless Unit Pg 79 Item 9.7 9.7.3 4 Tr Cassette Three Phase, 196. Supplying, Errection., Testing , Commissioning Packaged Type Ductable Split Air Conditionere With Microprocessor Control, Fitted With Twin Scroll Compressors With R22/ Latest Refrigerant . The Unit Shall Be Pre-Wired To Operate On 415 Volts 50 Hz Ac Supply. The Unit Shall Comprise Evaporated Condenser Unit , Inddor-Outdoor Motor Fans, Suitable Over Vent Fins Made Of Aluminium , Copper Refrigerant Coil Etc.. Complete And Corded Control Unit Pg 79 Item 9.8 9.8.1 Capacity : 3Tr, 197. Supplying, Errection., Testing , Commissioning Packaged Type Ductable Split Air Conditionere With Microprocessor Control, Fitted With Twin Scroll Compressors With R22/ Latest Refrigerant . The Unit Shall Be Pre-Wired To Operate On 415 Volts 50 Hz Ac Supply. The Unit Shall Comprise Evaporated Condenser Unit , Inddor-Outdoor Motor Fans, Suitable Over Vent Fins Made Of Aluminium , Copper Refrigerant Coil Etc.. Complete And Corded Control Unit Pg 79 Item 9.8 9.8.2 Capacity : 4.25Tr, 198. Supplying, Errection., Testing , Commissioning Packaged Type Ductable Split Air Conditionere With Microprocessor Control, Fitted With Twin Scroll Compressors With R22/ Latest Refrigerant . The Unit Shall Be Pre-Wired To Operate On 415 Volts 50 Hz Ac Supply. The Unit Shall Comprise Evaporated Condenser Unit , Inddor-Outdoor Motor Fans, Suitable Over Vent Fins Made Of Aluminium , Copper Refrigerant Coil Etc.. Complete And Corded Control Unit Pg 79 Item 9.8 9.8.3 Capacity : 5.5 Tr, 199. Supplying, Errection., Testing , Commissioning Packaged Type Ductable Split Air Conditionere With Microprocessor Control, Fitted With Twin Scroll Compressors With R22/ Latest Refrigerant . The Unit Shall Be Pre-Wired To Operate On 415 Volts 50 Hz Ac Supply. The Unit Shall Comprise Evaporated Condenser Unit , Inddor-Outdoor Motor Fans, Suitable Over Vent Fins Made Of Aluminium , Copper Refrigerant Coil Etc.. Complete And Corded Control Unit Pg 79 Item 9.8 9.8.4 Capacity : 8.5 Tr, 200. Supplying, Errection., Testing , Commissioning Packaged Type Ductable Split Air Conditionere With Microprocessor Control, Fitted With Twin Scroll Compressors With R22/ Latest Refrigerant . The Unit Shall Be Pre-Wired To Operate On 415 Volts 50 Hz Ac Supply. The Unit Shall Comprise Evaporated Condenser Unit , Inddor-Outdoor Motor Fans, Suitable Over Vent Fins Made Of Aluminium , Copper Refrigerant Coil Etc.. Complete And Corded Control Unit Pg 79 Item 9.8 9.8.5 Capacity : 11Tr, 201. Supplying, Errection., Testing , Commissioning Packaged Type Ductable Split Air Conditionere With Microprocessor Control, Fitted With Twin Scroll Compressors With R22/ Latest Refrigerant . The Unit Shall Be Pre-Wired To Operate On 415 Volts 50 Hz Ac Supply. The Unit Shall Comprise Evaporated Condenser Unit , Inddor-Outdoor Motor Fans, Suitable Over Vent Fins Made Of Aluminium , Copper Refrigerant Coil Etc.. Complete And Corded Control Unit Pg 79 Item 9.8 9.8.5 Capacity : 17Tr, 202. Supplying And Installation Of 5/8” And 7/8” Hard Drawn Refrigerant Pipe And Insulation Suitable For 11 Tr Ductable Split Air Conditioners Pg 80 Item 9.22, 203. Replacement Of Compressor For 5.5 Tr Ductable Split Air Conditioner Including Gas Charging Including Releasing And Re-Fixing And To And Fro Transportation Charges On Exchange Basis, 204. Replacement Of Compressor For 8.5 Tr Ductable Split Air Conditioner Including Gas Charging Including Releasing And Re-Fixing And To And Fro Transportation Charges On Exchange Basis, 205. Replacement Of Controller For 5.5 Tr Chiller, 206. Replacement Of Heat Exchanger For 5.5 Tr Ductable Ac Unit, 207. Replacement Of Heat Exchanger Inside The Indoor Unit Of 8.5 Tr Ductable Ac Unit, 208. Supplying Of Universal Remote For Air Conditioners, 209. Supplying A 25 Litres Vertical /Horizontal Type Wall Mounting Electrical Water Heater With 22 Swg Copper /Ss Sheet Metal Inner Container Tinned Inside And Anticorrosive Painted Outside And 20 Swg M.S Sheet Metal Outer Cover Between Inner And Outer Container Filled With Glass Wool Complete With Inlet And Outlet Pipes With Inlet And Outlet Pipes So Arranged That Water Flow Inside Results In Water To Flow Out From The Inner Container Without Turbulence.The Inner Container Shall Have Direct Immersion Type Copper Tube Nickel Plate 2 Kw Capacity Element With A Neon Indicator Fitted With 20A Capacity 25 To 85 Degree Centigrade Range Thermostat .The Water Heater Shall Completely Be Wired With 40/0.0076” Inch 3 Core Copper Flexible Wire Of 1.5 Meters Length And The Outlet Container Provided With Heavy Gauge Brackets For Wall Mountin Pg 83 Item 10.1.1 10.1.1 25 Litres, 210. Supplying A 35 Litres Vertical /Horizontal Type Wall Mounting Electrical Water Heater With 22 Swg Copper /Ss Sheet Metal Inner Container Tinned Inside And Anticorrosive Painted Outside And 20 Swg M.S Sheet Metal Outer Cover Between Inner And Outer Container Filled With Glass Wool Complete With Inlet And Outlet Pipes With Inlet And Outlet Pipes So Arranged That Water Flow Inside Results In Water To Flow Out From The Inner Container Without Turbulence.The Inner Container Shall Have Direct Immersion Type Copper Tube Nickel Plate 2 Kw Capacity Element With A Neon Indicator Fitted With 20A Capacity 25 To 85 Degree Centigrade Range Thermostat .The Water Heater Shall Completely Be Wired With 40/0.0076” Inch 3 Core Copper Flexible Wire Of 1.5 Meters Length And The Outlet Container Provided With Heavy Gauge Brackets For Wall Mountin Pg 83 Item 10.1.1 10.1.2 35 Litres, 211. Supplying A 50 Litres Vertical /Horizontal Type Wall Mounting Electrical Water Heater With 22 Swg Copper /Ss Sheet Metal Inner Container Tinned Inside And Anticorrosive Painted Outside And 20 Swg M.S Sheet Metal Outer Cover Between Inner And Outer Container Filled With Glass Wool Complete With Inlet And Outlet Pipes With Inlet And Outlet Pipes So Arranged That Water Flow Inside Results In Water To Flow Out From The Inner Container Without Turbulence.The Inner Container Shall Have Direct Immersion Type Copper Tube Nickel Plate 2 Kw Capacity Element With A Neon Indicator Fitted With 20A Capacity 25 To 85 Degree Centigrade Range Thermostat .The Water Heater Shall Completely Be Wired With 40/0.0076” Inch 3 Core Copper Flexible Wire Of 1.5 Meters Length And The Outlet Container Provided With Heavy Gauge Brackets For Wall Mountin Pg 83 Item 10.1.3 10.1.3 50 Litres, 212. Errection Charges For Fixing A 35 Litres Capacity Wall Mounting Boiler (Electrical Geysers)Using Bolts ,Flat At One End Nut And Washers At The Other End For Through Bolts And Nuts And Washers With 150X450x600mm Back Plate And Wiring Complete With 15A 3Pin Top Of Approved Make Pg 109 Item 17.13.1 17.13.1 Up To 30 Litres, 213. Errection Charges For Fixing A 35 Litres Capacity Wall Mounting Boiler (Electrical Geysers)Using Bolts ,Flat At One End Nut And Washers At The Other End For Through Bolts And Nuts And Washers With 150X450x600mm Back Plate And Wiring Complete With 15A 3Pin Top Of Approved Make Pg 109 Item 17.13.2 17.13.2 35 To 50 Litres, 214. Supplying…100 Amps Rated 3 Phase With Neutral Bus Bar Using Required Capacity Electrolytic Aluminium Strips Covered With Heat Shrinkable Coloured Pvc Sleeve , Mounted On Phenolic/Frp?Dmc Insulator Which Are Mounted On Powder Coated 40X6mm M.S Flat Frame Work In Existing Panel Board . The Bus Bar Shall Have Suitable Holes For Termination Of Incoming And Outgoing Cables As Per Is Specification With Necessary Bolts, Nuts And Washers Etc.. Complete Pg 49 Item 6.38 6.38.1 100 Amps 4X30x6mm Alkuminium Strips, 215. Supplying…250 Amps Rated 3 Phase With Neutral Bus Bar Using Required Capacity Electrolytic Aluminium Strips Covered With Heat Shrinkable Coloured Pvc Sleeve , Mounted On Phenolic/Frp?Dmc Insulator Which Are Mounted On Powder Coated 40X6mm M.S Flat Frame Work In Existing Panel Board . The Bus Bar Shall Have Suitable Holes For Termination Of Incoming And Outgoing Cables As Per Is Specification With Necessary Bolts, Nuts And Washers Etc.. Complete Pg 49 Item 6.38 6.38.2 250 Amps 4X30x10mm Alluminium Strips, 216. Supplying…400 Amps Rated 3 Phase With Neutral Bus Bar Using Required Capacity Electrolytic Aluminium Strips Covered With Heat Shrinkable Coloured Pvc Sleeve , Mounted On Phenolic/Frp/Dmc Insulator Which Are Mounted On Powder Coated 40X6mm M.S Flat Frame Work In Existing Panel Board . The Bus Bar Shall Have Suitable Holes For Termination Of Incoming And 218Outgoing Cables As Per Is Specification With Necessary Bolts, Nuts And Washers Etc.. Complete Pg 49 Item 6.38 6.38.3 400 Amps 4X30x10mm Alluminium Strips, 217. Supplying 600…Amps Rated 3 Phase With Neutral Bus Bar Using Required Capacity Electrolytic Aluminium Strips Covered With Heat Shrinkable Coloured Pvc Sleeve , Mounted On Phenolic/Frp/Dmc Insulator Which Are Mounted On Powder Coated 40X6mm M.S Flat Frame Work In Existing Panel Board . The Bus Bar Shall Have Suitable Holes For Termination Of Incoming And Outgoing Cables As Per Is Specification With Necessary Bolts, Nuts And Washers Etc.. Complete Pg 49 Item 6.38 6.38.4 600 Amps 4X30x10mm Alluminium Strips, 218. Supplying…Amps Rated 3 Phase With Neutral Bus Bar Using Required Capacity Electrolytic Aluminium Strips Covered With Heat Shrinkable Coloured Pvc Sleeve , Mounted On Phenolic/Frp/Dmc Insulator Which Are Mounted On Powder Coated 40X6mm M.S Flat Frame Work In Existing Panel Board . The Bus Bar Shall Have Suitable Holes For Termination Of Incoming And Outgoing Cables As Per Is Specification With Necessary Bolts, Nuts And Washers Etc.. Complete Pg 49 Item 6.38 6.38.5 1000 Amps Double Run Of 60X10mm Per Phase And Single Run Of 60X10mm For Neutral, 219. Supplying And Fixing Angel Iron Frame Work Fabricated Out Of M S Angel Iron And Ms Flat With Bolts , Washers Etc.. And Painted With 2 Coates Of Red Oxide And The Two Coates Of Approved Paint Pg 49 Item 6.39 6.39.1 40X40x6mm, 220. Supplying And Fixing Angel Iron Frame Work Fabricated Out Of M S Angel Iron And Ms Flat With Bolts , Washers Etc.. And Painted With 2 Coates Of Red Oxide And The Two Coates Of Approved Paint Pg 49 Item 6.39 6.39.2 50X50x6mm, 221. Supplying And Fixing Angel Iron Frame Work Fabricated Out Of M S Angel Iron And Ms Flat With Bolts , Washers Etc.. And Painted With 2 Coates Of Red Oxide And The Two Coates Of Approved Paint Pg 49 Item 6.396.39.3 75X75x6mm, 222. Supplying And Fixing Angel Iron Frame Work Fabricated Out Of M S Angel Iron And Ms Flat With Bolts , Washers Etc.. And Painted With 2 Coates Of Red Oxide And The Two Coates Of Approved Paint Pg 49 Item 6.396.39.4 50X100x50x6mm C Channel, 223. Supplying And Fixing Angel Iron Frame Work Fabricated Out Of M S Angel Iron And Ms Flat With Bolts , Washers Etc.. And Painted With 2 Coates Of Red Oxide And The Two Coates Of Approved Paint Pg 49 Item 6.396.39.5 75X150x75x6mm C Channel, 224. Supplying And Fixing Surface /Flush Mounting Unbreakable Pvc Modular Box Suitable For Mounting Switch Plates With Due Groove Cutting In Brick/Cc Wall Including Necessary Rawl Plugs, Machine Screws Etc.. Complete Pg 15 Item 3.43.4.1 1-3 Way, 225. Supplying And Fixing Surface /Flush Mounting Unbreakable Pvc Modular Box Suitable For Mounting Switch Plates With Due Groove Cutting In Brick/Cc Wall Including Necessary Rawl Plugs, Machine Screws Etc.. Complete Pg 15 Item 3.43.4,2 4-5 Way, 226. Supplying And Fixing Surface /Flush Mounting Unbreakable Pvc Modular Box Suitable For Mounting Switch Plates With Due Groove Cutting In Brick/Cc Wall Including Necessary Rawl Plugs, Machine Screws Etc.. Complete Pg 15 Item 3.4.3 6-8 Way, 227. Supplying And Fixing Surface /Flush Mounting Unbreakable Pvc Modular Box Suitable For Mounting Switch Plates With Due Groove Cutting In Brick/Cc Wall Including Necessary Rawl Plugs, Machine Screws Etc.. Complete Pg 15 Item 3.4.4 10-12 Way, 228. Supplying And Fixing Surface /Flush Mounting Unbreakable Pvc Modular Box Suitable For Mounting Switch Plates With Due Groove Cutting In Brick/Cc Wall Including Necessary Rawl Plugs, Machine Screws Etc.. Complete Pg 15 Item 16-18 Way, 229. Supplying And Flush Mounting Powder Coated/ Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone /Cc Wall3.5.1 1-3 Way, 230. Supplying And Flush Mounting Powder Coated/ Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone /Cc Wall3.5.2 4-5 Way, 231. Supplying And Flush Mounting Powder Coated/ Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone /Cc Wall3.5.3 6 Way, 232. Supplying And Flush Mounting Powder Coated/ Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone /Cc Wall3.5.3 8 Way, 233. Supplying And Flush Mounting Powder Coated/ Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone /Cc Wall3.5.5 10-12 Way, 234. Supplying And Flush Mounting Powder Coated/ Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone /Cc Wall3.5.6 16 Way, 235. Supplying And Flush Mounting Powder Coated/ Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone /Cc Wall18 Way, 236. Supplying And Fixing Superior Quality Modular Switch Mounting Poly Carbonate Plate With Necessary Supporting Back Plate With Required No,S Of Machine Screws , Bolts , Nuts Etc.. Complte On The Existing Metal/Pvc Box Pg 16 Item3.6.1 1 To 3 Module, 237. Supplying And Fixing Superior Quality Modular Switch Mounting Poly Carbonate Plate With Necessary Supporting Back Plate With Required No,S Of Machine Screws , Bolts , Nuts Etc.. Complte On The Existing Metal/Pvc Box Pg 16 Item3.6.2 4 Module, 238. Supplying And Fixing Superior Quality Modular Switch Mounting Poly Carbonate Plate With Necessary Supporting Back Plate With Required No,S Of Machine Screws , Bolts , Nuts Etc.. Complte On The Existing Metal/Pvc Box Pg 16 Item3.6.3 6 Module, 239. Supplying And Fixing Superior Quality Modular Switch Mounting Poly Carbonate Plate With Necessary Supporting Back Plate With Required No,S Of Machine Screws , Bolts , Nuts Etc.. Complte On The Existing Metal/Pvc Box Pg 16 Item3.6.4 8 Module, 240. Supplying And Fixing Superior Quality Modular Switch Mounting Poly Carbonate Plate With Necessary Supporting Back Plate With Required No,S Of Machine Screws , Bolts , Nuts Etc.. Complte On The Existing Metal/Pvc Box Pg 16 Item3.6.5 12 Module, 241. Supplying And Fixing Superior Quality Modular Switch Mounting Poly Carbonate Plate With Necessary Supporting Back Plate With Required No,S Of Machine Screws , Bolts , Nuts Etc.. Complte On The Existing Metal/Pvc Box 18 Module, 242. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A3.7.1 6 Amps One Way, 243. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A 3.7.2 6 Amps Two Way, 244. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A3.7.3 6 Amps 3 Way Socket, 245. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A3.7.4 Stepped Fan Regulator, 246. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A 3.7.5 600 Watts Dimmer, 247. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A 3.7.6 1000-1200 Watts Dimmer, 248. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A 3.7.7 16 Amps One Way Switch, 249. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7Group A 3.7.8 6 Amps Bell Push, 250. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7 Group A 3.7.9 32 Amps Dp Switch, 251. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7 Group A 3.7.10 6/16 Amps Universal Socket, 252. Supplying And Fixing Of Modular Switch / Socket / Stepped Electronic Fan Regulator / Dimmer/ Telephone Socket Etc.. On Existing Modular Switch Plate As Per Is 3854 And Is 1293 Pg 16 Item 3.7 Group A 3.7.11 Rj45/I.O Socket, 253. Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And `C’ Type Curve,Indicator On/Off,Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 47 Item 6.16 6.16.1 5-32 Amps Sp, 254. Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And `C’ Type Curve,Indicator On/Off,Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 47 Item 6.166.16.2 40-63 Amps Sp, 255. Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And `C’ Type Curve,Indicator On/Off,Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 47 Item 6.166.16.3 5-32 Amps Dp, 256. Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And `C’ Type Curve,Indicator On/Off,Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 47 Item 6.166.16.4 40-63 Amps Dp, 257. Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And `C’ Type Curve,Indicator On/Off,Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 47 Item 6.16 6.16.5 5-32 Amps Tpn, 258. Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And `C’ Type Curve,Indicator On/Off,Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 47 Item 6.16 6.16.6 40-60 Amps Tpn, 259. Supplying And Fixing And Wiring Of Led Type Panel Board Indicating Lamp With Required Colour Suitable For 220 Volts 50 Hz Ac 12/24 Volts Dc Pg 48 Item 6.36, 260. Supplying And Fixing And Wiring 1000/%A To 1600 /5A Burden Class -1 Current Transformers Pg 48 Item 6.34, 261. Supplying And Fixing And Wiring Electronic 10-40 Amps Three Phase 4 Wire Class-1 Accuracy Energy Meter Pg 49 Item 6.33, 262. Supplying And Fixing And Wiring Heavy Duty Low Voltage Capacitors Conforming To Is 2834 , 3 Phase 400/440 Volts Grade , For Power Factor Improvement Of Rotating Machiners Pg 48 Item 6.35, 263. Suplying Of Multi Function Digital Meter With Three Phase Back Light Lcd Type Display For Voltage , Cutrrent, Frequency, Power, Power Factor, Kva,Kwh, Kvar Suitable For 3 Phase 4 Wire Network With Ip 54 Degeree Of Protection And Completely Wired As Required With Communication Port And Class 0.5 S Accuracy Pg 48 Item 6.31, 264. Supplying And Fixing Of And Wiring Earth Leakage Miniature Circuit Breakers (Elmcb) 240/450 Volts Up To 300Ma Sensitivity On Existing Wood/ Panel Board Pg 47 Item 6.18 6.18.3 32-40 Amps 4 Pole, 265. Supplying And Fixing Of And Wiring Earth Leakage Miniature Circuit Breakers (Elmcb) 240/450 Volts Up To 300Ma Sensitivity On Existing Wood/ Panel Board Pg 47 Item 6.18 6.18.4 40-63 Amps 4 Pole, 266. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 I- Single Door 6.17.1 4 Way Sp &N, 267. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 I- Single Door 6.17.2 8Way Sp &N, 268. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 I- Single Door 6.17.3 12 Way Sp &N, 269. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 Ii- Double Door 6.17.4 4 Way Sp &N, 270. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 Ii- Double Door 6.17.5 8 Way Sp &N, 271. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 Ii- Double Door 6.17.6 12 Way Sp &N, 272. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 Ii- Double Door 6.17.7 4 Way Tp &N, 273. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 Ii- Double Door 6.17.8 6Way Tp &N, 274. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 Ii- Double Door 6.17.9 8 Way Tp &N, 275. Supplying And Fixing Regular Mcb Distribution Boards On Wall/Wood Board/Flush Mounting Using Required Clamps , Bolts, Nuts Etc.. With Provision For Fixing Suitable Type Capacity Mcb,S Single Phase/ 3Phase / Single Door With Powder Coated Painting . Made Out Of 14 Swg Ms Enclosure Pg 47 Item 6.17 Ii- Double Door 6.17.10 12 Way Tp &N, 276. Supplying And Fixing Of Led 20/22 Watts 4 Ft- Led Batten Pvc With Warranty Of 2 Years Yeras Ye 2 Years Years With High Quality Diffusers With 25000 Burning Hours, 277. Supplying And Fixing Of Led 20/22 Watts 4 Ft- Led Batten Pvc With Warranty Of 2 Years Yeras Ye 2 Years Years With High Quality Diffusers With 25000 Burning Hours, 278. Supplying And Fixing Of Led 4 Ft Batten 36 Watts With Warranty Of Two Year, 279. Supplying An Fixing Of Round Type Ceiling Mounted Led 12 Watts, 280. Supplying An Fixing Of Round Type Ceiling Mounted Led 18 Watts, 281. Supplying An Fixing Of Round Type Surface Mounted Led 18 Watts, 282. Supplying An Fixing Of Round Type Surface Mounted Led 22 Watts, 283. Supplying Of Fluorescent Tube 4Ft-36 Watts, 284. Supplying Of Fluorescent Tube 2Ft-18/20 Watts, 285. Supplying Of 2 Ft Led Batten 2’-14 Watts, 286. Supplying Of 4 Ft Led Batten4ft-20/22 Watts With Pvc Body, 287. Supplying Of 4 Ft Led Batten4ft-20/22 Watts With Alluminium Body, 288. Supplying Of 36 Watts 4 Ft Led Batten, 289. Supplying And Fixing Of Led Down Light 1’X1’ -36 Watts, 290. Supplying And Fixing Of Led Down Light 2’X2’ -36 Watts, 291. Supplying And Fixing Of Led Gate Lights With High Quality Diffuser 48 Watts, 292. Supplying And Fixing Of 2 Pin/4Pin 18 Watts Cfl Lamp, 293. Supplying And Fixing Of 4 Pin 36 Watts Cfl, 294. Supplying And Fixing Of Choke For 18 Watts Cfl, 295. Supplying And Replacement Of Florescent Tubes Pg 105 Item 16.15, 296. Supplying Of Heavy Duty Open Construction Ferromagnetic Copper Ballast For 20/40 Watts Fluore Fluorescent Tube Fitting, 297. Supplying Of Heavy Duty Open Construction Electronic Ballast Choke For 20/40 Watts Fluore 20/40 Watts Fluorescent Tube Fitting, 298. Supplying And Fixing Of Electronic Choke For 20/36 Watts Fluorescent Tube Fittings, 299. Supplying And Fixin Supplying And Fixing Of Heavy Duty Open Construction Ferromagnetic Copper Ballast For 20/40 W Ballast For 20/40 Watts Fluorescent Tube Fitting, 300. Supplying And Fixing Of 230 Volts 20/40 Watts Starters For Flourescent Tubes Pg No 105 Item 16.18, 301. Supplying And Fixing Of 230 Volts 20/40 Watts Fluorescent Lamp Holder Pg 105 Item 16.19, 302. Supplying Of 230 Volts 20/40 Watts Starters For Flourescent Tubes, 303. Supply And Fixing Of 230 Volts Cfl Holder Pg 105 Item 16.20 16.20.1 2 Pin Holder, 304. Supply And Fixing Of 230 Volts Cfl Holder Pg 105 Item 16.20 16.20.2 4 Pin Holder, 305. Supplying Of Incandescent Lamps 60 Watts, 306. Supplying Of Incandescent Lamps 100 Watts, 307. Supplying And Fixing Of Angel Holders, 308. Supplying And Fixing Of Batten Holders, 309. Supply Of Angle Holders, 310. Supplying Of Battern Holders, 311. Supplying Of Insulation Tapes, 312. Supplying And Of Heating Element Of Geyser Pg 106 Item 16.23, 313. Supplying And Replacingof Thermostat 20 Amps 20 To 25 Inch Range Thermostat Pg 104 Item 16.7, 314. Supplying And Thermostat 20 Amps 20 To 25 Inch Range Thermostat, 315. Providing Re- Winding For Ceiling Fans 1200Mm Inclusine Of To And Fro Transportation Charges And Releasing And Refixing Pg 104 Ite 16.4 16.4.3 1200Mm, 316. Supplying And Fixing Of Heating Element For Racold Make Geysers, 317. Supplying And Fixing Of Thermostat For Racold Make Geysers, 318. Supplying And Fixing Of Condenser For Ceiling Fans Pg 104 Item 16.3 16.3.1 Up To 4 Mfd, 319. Supplying Of 2.5 Mfd Capacitors For Ceiling Fan, 320. Supplying And Fixing Of One 230 Volts Bell Or Buzzer And A Bell Type Bell Push With Gang Box Fixed On Necessary Wooden Or Rawl Olugs Using Nf Screws Pg 104 Item 16.1, 321. Supplying And Fixing Of One 230 Volts Ding Dong Bell And A Flush Type Bell Push With Gang Box Fixed On Necessary Wooden Or Rawl Plugs Using Nf Screws Pg 104 Item 16.2 16.2.1 Ding Dong Bell, 322. Supplying And Fixing Of One 230 Volts Ding Dong Bell And A Flush Type Bell Push With Gang Box Fixed On Necessary Wooden Or Rawl Plugs Using Nf Screws Pg 104 Item 16.2 16.2.2 Musical, 323. Supplying And Fixing Of One 230 Volts Ding Dong Bell And A Flush Type Bell Push With Gang Box Fixed On Necessary Wooden Or Rawl Plugs Using Nf Screws Pg 104 Item 16.2 16.2.3 Remote, 324. Providing Re- Winding For 1 Hp Single Phase Motor Including To And Fro Transportation Charges Releasing And Re-Fixing And Replacement Of Bearings Etc And Condenser, 325. Providing Re- Winding For 5 Hp Single Phase Motor Including To And Fro Transportation Charges Releasing And Re-Fixing And Replacement Of Bearings, Gaskets , Flangues A And Painting Of Motor To The Existing Color, 326. Providing Re- Winding For 5 Hp Single Phase Motor Including To And Fro Transportation Charges Releasing And Re-Fixing And Replacement Of Bearings, Gaskets , Flangues A And Painting Of Motor To The Existing Color, 327. Supplying And Fixing Coil For The Contactors 100-125 Amps, 328. Supplying And Fixing Of Contactor Coil For 400 Amps Including Releasing And Re-Fixing And To And Fro Transportation Charges, 329. Providing Services For 30 Kva Stabilizers And Re Conditioning Etc.., 330. Supplying And Fixing Of Coil For 800 Amps Power Contactor And 800 Amps Acb,S, 331. Supplying And Fixing Of 4 Pole Power Contactor With No/Nc Contacts On Existing Wood/ Panel Board Using Necessary Bolts , Nuts , Washers And Wiring Etc,, Complete With Ac-3 Rating And As Per Is-13947 Pg 45 Item 6.12 6.12.1 25 Amps, 332. Supplying And Fixing Of 4 Pole Power Contactor With No/Nc Contacts On Existing Wood/ Panel Board Using Necessary Bolts , Nuts , Washers And Wiring Etc,, Complete With Ac-3 Rating And As Per Is-13947 Pg 45 Item 6.12 6.12.2 40 Amps, 333. Supplying And Fixing Of 4 Pole Power Contactor With No/Nc Contacts On Existing Wood/ Panel Board Using Necessary Bolts , Nuts , Washers And Wiring Etc,, Complete With Ac-3 Rating And As Per Is-13947 Pg 45 Item 6.12 6.12.4 100-125 Amps, 334. Supplying And Fixing Of 4 Pole Power Contactor With No/Nc Contacts On Existing Wood/ Panel Board Using Necessary Bolts , Nuts , Washers And Wiring Etc,, Complete With Ac-3 Rating And As Per Is-13947 Pg 45 Item 6.12 6.12.6 225-250 Amps, 335. Supplying And Fixing Of 4 Pole Power Contactor With No/Nc Contacts On Existing Wood/ Panel Board Using Necessary Bolts , Nuts , Washers And Wiring Etc,, Complete With Ac-3 Rating And As Per Is-13947 Pg 45 Item 6.12 6.12.7 400 Amps, 336. Supplying And Fixing Of 4 Pole Power Contactor With No/Nc Contacts On Existing Wood/ Panel Board Using Necessary Bolts , Nuts , Washers And Wiring Etc,, Complete With Ac-3 Rating And As Per Is-13947 Pg 45 Item 6.12 6.12.8 700-800 Amps, 337. Supplying Of On-Load Change Over Switch 4 Poles Ac-23 A Duty , 50 Hz Ac Supply Pg 45 Item 6.11 6.11.1 63 Amps, 338. Supplying Of On-Load Change Over Switch 4 Poles Ac-23 A Duty , 50 Hz Ac Supply Pg 45 Item 6.11 6.11.2 100-125 Amps, 339. Supplying Of On-Load Change Over Switch 4 Poles Ac-23 A Duty , 50 Hz Ac Supply Pg 45 Item 6.11 6.11.4 250 Amps, 340. Supplying Of On-Load Change Over Switch 4 Poles Ac-23 A Duty , 50 Hz Ac Supply Pg 45 Item 6.11 6.11.5 400 Amps, 341. Supplying Of On-Load Change Over Switch 4 Poles Ac-23 A Duty , 50 Hz Ac Supply Pg 45 Item 6.11 6.11.6 630 Amps, 342. Supplying Of On-Load Change Over Switch 4 Poles Ac-23 A Duty , 50 Hz Ac Supply Pg 45 Item 6.11 6.11.7 800 Amps, 343. Supplying Of Switch Disconnector Fuse Unit (Tpn) Hrc Type ( But Without Hrc Fuses) With Ac-23 Amps Duty And As Per Is-13947 Pg 45 Item 6.8 6.8.1 63 Amps, 344. Supplying Of Switch Disconnector Fuse Unit (Tpn) Hrc Type ( But Without Hrc Fuses) With Ac-23 Amps Duty And As Per Is-13947 Pg 45 Item 6.8 6.8.2 125 Amps, 345. Supplying Of Switch Disconnector Fuse Unit (Tpn) Hrc Type ( But Without Hrc Fuses) With Ac-23 Amps Duty And As Per Is-13947 Pg 45 Item 6.8 6.8.1 200 Amps, 346. Supplying Of Switch Disconnector Fuse Unit (Tpn) Hrc Type ( But Without Hrc Fuses) With Ac-23 Amps Duty And As Per Is-13947 Pg 45 Item 6.8 6.8.1 250 Amps, 347. Supplying Of Switch Disconnector Fuse Unit (Tpn) Hrc Type ( But Without Hrc Fuses) With Ac-23 Amps Duty And As Per Is-13947 Pg 45 Item 6.8 6.8.1 400 Amps, 348. Supplying And Fixing Hrc Fuse Link On Existing Switch Fuse Base As Per Is 13703 Pg 45 Item 6.10 6.10.1 Up To 63 Amps, 349. Supplying And Fixing Hrc Fuse Link On Existing Switch Fuse Base As Per Is 13703 Pg 45 Item 6.10 6.10.2 100 Amps, 350. Supplying And Fixing Hrc Fuse Link On Existing Switch Fuse Base As Per Is 13703 Pg 45 Item 6.10 6.10.3 Up To 125 Amps, 351. Supplying And Fixing Hrc Fuse Link On Existing Switch Fuse Base As Per Is 13703 Pg 45 Item 6.10 6.10.4 200 Amps, 352. Supplying And Fixing Hrc Fuse Link On Existing Switch Fuse Base As Per Is 13703 Pg 45 Item 6.10 6.10.5 250-800 Amps, 353. Supplying Push Botton Operated Direct On Line Starters With An Antiweld Silver Cadmium Oxide Contactor With Replaceable Fixed And Movim=Ng Contacts And Bimetallic Thermal Overload Relay Help In Anticorrosion Trated Sheet Steel Or Iron Cld Enclosure And Fixing The Same To Suitable Capacity Wires For 400/440 Volts 3 Phase Motor/ Single Phase Motor Up To 5 Hp Pg 44 Item 6.1, 354. Supplying Fully Automatic Star –Delta Starter Unit Push Button Type Suitable With Suitable Wires, 3 Contactors, One Adjustable Thermal Timer Mounted On A Common Base Plate Held In Steel Enclosure For Use On 400/440 Volts 3 Phase And Wired After Fixing To The Existing Wooden Board For Motor Pg 44 Item 6.2 6.2.1 Up To 12.5 Hp, 355. Fixing Halogen / Metal Halide /Led Flood Lightiings Fitted Over The Existing Poles/ Wall Ceiling Including Clamps , Bolts , Nuts And Wiring Using Suitable Capacity Wires Pg 108 Item 17.5, 356. Fixing Charges Of Post Top/ Gate/ Garden Fitting / Led On The The Existing Ci?Gi Or Any Other Pipe Using Required Size Of Reducer Wiring Using Suitable Wires Pg 108 Item 17.6, 357. Supplying And Fixing Of 150 Watts Led Street Lights With Isi/Ce Cofirmed, 358. Supplying And Fixing Of 200 Watts Flood Lights With Isi/Ce Confirmed., 359. Supply And Fixing Of 4 Pole Power Contactor With No/Nc Contacts On Existing Wood/Panel Board Using Necessary Bolts, Nuts, Washers And Wiring Etc., Complete With Ac-3 Rating And As Per Is-13947. 100-125Amps, 360. Supplying And Fixing Electro Mechanical Timer (Without Contactor) Using Necessary Bolts, Nuts And Washers Etc. Group ‘A’ (Pwd Ele Sr Of 2007-08) Make : L & T, 361. Supplying And Fixing Angle Iron Frame Work Fabricated Out Of M.S Angle Iron… And M.S. Flat… With Bolts, Washers Etc., And Painted With 2 Coats Of Red Oxide And Then Two Coats Of Approved Paint. 40X40x6mm, 362. Supplying And Fixing Hylum Brand Hand Plastic Sheet 3Mm Thick With Necessary Nitches For Fixing Switches, Regulators Etc., And Fixing On Existing Wood Or Metal Box Using N.F.Screws, 363. Led Street Light. Supply Of Led Streetlight With Pressure Die Cast Aluminum Housing Body With Optimal Heat Sink For Better Thermal Dissipation. Diffuser With Injection Moulded & Is Made Of Polycarbonate Material With High Transmission Index, Delivering Superior Light Output. Rated Life Burning Hrs. 50000 Hr. @ Lumen Maintenance Of 70%. Cct > 5500K, Ip 66 Optical And Electrical Compartment & Impact Resistance Of Complete Luminaire > Ik08. Power Factor >0.9 With Mains Current Should Not Be Greater Than 0.1A To 0.7A & Surge Protection- Min 4 Kv Along With Over Voltage/Overload, Short Circuit/ Miswiring Protection. Compatible For Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universal Voltage Driver To Operate Wide Voltage Range From 100V To 270V 50/60Hz Application. Over Load & Short Circuit Protection Ensures Reliable Operation In S Ite Of Problem In Output Side. Compliance To Is 10322/Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb. Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimal Tools. Led Light Fixture With ........W System Power Consumption. Led Efficiency>130Lm/W At 1W & Fixture Efficiency >80Lm/W With Nominal Cri 75+. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. . Luminaire Manufacturer Should Have In-House Facility Accredited By Nabl/Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Warranty Of 5 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Above Should Be Given By Led Source Manufacturer. Suitable For A1/A2 Roads As Per Is 1944 Part I & Part Ii. 150 Watts Make:Syska/Cg, 364. Fabricating, Supplying And Erecting Swaged Tubular Pole Of Height …Mtr Having Three Sections, And Providing Two Coats Of Red Oxide Paint And Finished With Two Coats Of Enameled Paint Of Approved Quality And Colour And M.S. Base Plate Of Suitable Size Welded At The Bottom Of The Pole(As Per Is) And 40Mm Dia Gi / Flexible Pvc Pipe Of 1 Mtr Length Fitted To The Heavy Gauge Polycarbonate Control Box Including 5Way Connector Of Size 167X125x82mm For 7.5M Pole/200X160x98mm For Remaining Length Of Pole With Front Opening Cover, With Locking Arrangements And Suitable Capacity Mcb / Dp Switch, The Pole Shall Be Erected In Cement Concrete Work (1:2:4) Including Excavation And Refilling Of Planting Depth Of The Pole To The Ground Level And The Coping Cc Shall Be Up To 0.6M Above Ground Level As Per Is 2713 - 7. Erection Of Heavy Duty Pole On Footpath / Median 5.13.1.1) 9Mt (5Mt Hb,165.1Mm Dia 4.85Mm Thick X2m Hm, 139.7Mm Dia 4.50Mm Thick X 2M Ht,114.3Mm Dia 3.65Mm Thick) As Per Is 410 Sp 32 Pg 34 Item 5.13.1.1, 365. Supplying And Fixing Telescopic M.S. Bracket Fabricated By Using 0.5M Length 4” Dia Telescopic M. S. Pipe, With 2” Dia 1.5M Long M. S. Bracket And Are Welded With Suitable Angle, Using 6Mm Thick M. S. Sheet, Grip Bolts & Nuts, As Required, Suitable For 9 To 12 Mtrs. M. S. Tubular Pole, With Necessary Two Coats Of Painting, With All Other Accessories. Single Bracket 1.5 Mtr. Length, 366. Suspension Clamp Assembly Including Pole Clamps With Labour Cost. Bescom Sr 2012-13, 367. Piercing Connector Suitable For 16 Sq Mm To 95 Sq Mm Ab Cable Streetlight Connections. Bescom 2012-13 (Cds-40), 368. Universal Hook, Bolts & Nuts Bescom 2012-13 (Cds-40), 369. Supply And Installation / Fixing / Provision Of Outdoor Type Thermoplastic Modular Panel Enclosure With Transparent Polycarbonate Lid, Shock Proof, Ip65 (Weather Proof), Rust Proof, Dust Proof, Water Proof, Corrosion Proof Having Internally Embedded Gasket On Both Lid And Flap Suitable To Fix Single Phase / Three Phase Energy Meter In Suitable Base Plate And Having A Provision For Fuse / Mcb Cutout With Suitable Transparent Hinged Flap Opening For Operating Mcb Along With Complete Tamper Proof Sealing Facility. 300Mmx300mmx214mm, 370. Supplying Of Led Floodlight With .......W System Power Consumption Pressure Die Cast Aluminum Housing With Powder Coating With Ip 65 Protection. 1, 200-275V Voltage With Electronic Driver, Pf>0.9, Should Meet Ansi 2G Vibration Test, Compliance To Ul/Ce With Class I. System Rating Shall Be 50K Hrs. @ Lumen Maintenance Of 70%, System Efficacy > 80Lm/W. Over Load & Short Circuit Protection Ensures Reliable Operation In Spite Of Problem In Output Side. Compliance To Is 10322/Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb. Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimal Tools. Led Light Fixture With ........W System Power Consumption. Led Efficiency>130Lm/W At 1W & Fixture Efficiency >80Lm/W With Nominal Cri >75. Luminaire Manufacturer Should Have In-House Facility Accredited By Nabl/Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark /Name Shall Be Engraved / Embossing On The Die Cast Housing/ Body Part. Warranty Of 5 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Above Should Be Given By Led Manufacturer. Led Floodlight 200 Watts, 371. Fabricating, Supplying And Erecting Swaged Tubular Pole Of Hight… Mtr Having Three Sections And Providing Two Coats Of Red Oxide Paint And Finished With Two Coats Of Enameled Paint Of Approved Quality And Colour And M.S.Base Plate Of Suitable Size Welded At The Bottom Of The Pole (As Per Is) And 40Mm Dia Gl / Flexible Pvc Pipe Of Mtr. Length Fitted To The Heavy Gauge Polycarbonate Control Box Including 5Way Connector Of Size 167X125x82mm For 7.5M Pole /200X160x98 Mm For Remaining Length Of Pole With Front Opeaning Cover, With Locking Arrangements And Suitable Capacity Mcb /Dp Switch. The Pole Shall Be Erected N Cement Concrete Work (1:2:4) Including Excavation And Refilling Of Planting Depth Of The Pole To The Ground Level And The Coping Cc Shall Be Up To 0.6M Above Ground Level As Per Is 2713–7. I.Erection Of Light Duty Pole On-Foot Path A) 7.5 Mt (4.5M Hb 114.3Mm Dia 4.05Mm Thick X 1.5M Hm 88.9Mm Dia 4.05Mm Thick X 1.5M Ht, 76.1Mm Dia 3.25Mm Thick) As Per Is 410 Sp 5 (Base Plate Of Size 300X300x6mm), 372. Supplying And Stringing Of 1.1Kv Grade Aerial Bunched Cable Stranded & Compacted Aluminum Phase Conductor, And Stranded Messenger Conductor With All Aluminum Alloy, Phase Conductor Is Insulated With Xlpe Compound, Insulated Messenger With Specified Is-14255:1995 & Confirming To Gtp Of Group-A. 3 X 16 + 1 X 25 + 1 X 16 Sq.Mm, 373. Wiring For Lighting / Power Circuit Using Onr Of Pvc Insulated 1100 Volts Grade Stranded Alluminium Un Sheathed Wire Single Core Cable In Open Or Concealed System Of Wiring As Per Is-694 Pg 12 Item 2.12 2.12. 1 4Sq Mm, 374. Wiring For Lighting / Power Circuit Using Onr Of Pvc Insulated 1100 Volts Grade Stranded Alluminium Un Sheathed Wire Single Core Cable In Open Or Concealed System Of Wiring As Per Is-694 Pg 12 Item 2.12 2.12. 3 10Sq Mm, 375. Supplying And Drawing 3 Core Flat Pvc Sheathed Submersible Pump Cable Manufactured With Electrolytic Grade Copper As Per Is -694:1990 & Conforming To Gtp Of Group –A Pg 12 Item 2.10 2.10.2 3 Core X2.5 Sqmm, 376. Supplying And Drawing 3 Core Flat Pvc Sheathed Submersible Pump Cable Manufactured With Electrolytic Grade Copper As Per Is -694:1990 & Conforming To Gtp Of Group –A Pg 12 Item 2.10 2.10.3 3 Core X4 Sqmm, 377. Supplying And Drawing 3 Core Flat Pvc Sheathed Submersible Pump Cable Manufactured With Electrolytic Grade Copper As Per Is -694:1990 & Conforming To Gtp Of Group –A Pg 12 Item 2.10 2.10.4 3 Core X6 Sqmm, 378. Supplying 4 Mm Thick White Plastic Plate And Covering For Junction Boxes Of Size .. Mm Conduit Using Necessary Machine Screws Pg 17 Item 3.11 3.11.1 80Mm, 379. Supplying 4 Mm Thick White Plastic Plate And Covering For Junction Boxes Of Size .. Mm Conduit Using Necessary Machine Screws Pg 17 Item 3.11 3.11.2 110Mm, 380. Supplying .. Way Plastic Gang Box And Fixing Using Necessary Wooden / Rawl / Phill Plugs And Screws Pg 17 Item 3.13 3.13.1 1 Way Gang Box, 381. Supplying .. Way Plastic Gang Box And Fixing Using Necessary Wooden / Rawl / Phill Plugs And Screws Pg 17 Item 3.13 3.13.2 2 To 4 Way Gang Box, 382. Supplying .. Way Plastic Gang Box And Fixing Using Necessary Wooden / Rawl / Phill Plugs And Screws Pg 17 Item 3.13 3.13.3 6 To 10 Way Gang Box, 383. Supplying .. Way Plastic Gang Box And Fixing Using Necessary Wooden / Rawl / Phill Plugs And Screws 12To 16 Way Gang Box, 384. Supplying And Fixing Of Metal Clad Industrial Plugs Pg 17 Item 3.14 3.14.2 20 Amps 2Pole + Earth 250 Volts Plug, 385. Supplying And Fixing Of Metal Clad Industrial Sockets Pg 17 Item 3.14 3.14.6 20 Amps 2Pole + Earth 250 Volts Socket, 386. Supplying And Fixing Of Metal Clad Industrial Plug Pg 17 Item 3.14 3.14.4 30 Amps 3Pole + Earth 440 Volts Plug, 387. Supplying And Fixing Of Metal Clad Industrial Plug Pg 17 Item 3.14 3.14.8 30 Amps 3Pole + Earth 440 Volts Socket Tools And Plant, 388. Supplying Of Multimeter Electro Machinical Type Bescom Sr 18-19 Sl No 502 Item Code 62.03( Clip-On-Mtere), 389. Supplying Of Multimeter Electronic Type Bescom Sr 18-19 Sl No 501 Item Code 62.02, 390. Supplying Of Portable Drilling Machine Bescom Sr 18-19 Sl No505 Item Code 62.06, 391. Supplying Of Megger 500 Volts Bescom Sr 18-19 Sl No:506 Item Code62.07, 392. Supplying Of Megger 2.5 Kv To 5 Kv Volts Bescom Sr 18-19 Sl No:507 Item Code62.08, 393. Supplying Of Silica Gel Bescom Sr 18-18 Sl No:510 Item Code 62.09, 394. Supplying Of Ring Spanners Bescom Sr18-19 Sl No:511 Item Code 62.12, 395. Supplying Of Tube Spanners Bescom Sr18-19 Sl No:512 Item Code 62.13, 396. Supplying Of Pipe Wrench 24 Inches Size Bescom Sr18-19 Sl No:513 Item Code 62.14, 397. Supplying Of Pipe Wrench 18 Inches Size Bescom Sr18-19 Sl No:513 Item Code 62.15, 398. Supplying Of Double End Spanners Bescom Sr:18-19 Sl No:515 Item Code 62.16, 399. Supplying Of Hack Saw Frame Bescom Sr 18-19 Sl No:516 Item Code62.17, 400. Supplying Of Hand Torch 3 Celled Bescom Sr 18-19 Sl No:518 Item Code62.19, 401. Supplying Of Rechargeble Led Hand Torch Bescom Sr 18-19 Sl No:519 Item Code62.20, 402. Supplying Of Insulated Cutting Fliers12 Inches Size Bescom Sr 18-19 Sl No:520 Item Code62.21, 403. Supplying Of Insulated Cutting Fliers 8 Inches Size Bescom Sr 18-19 Sl No:521 Item Code62.22, 404. Supplying Of Live Line Tester (Ht) Bescom Sr 18-19 Sl No:522 Item Code62.23, 405. Supplying Of Live Line Tester (Lt) Bescom Sr 18-19 Sl No:523 Item Code62.24, 406. Supplying Of Screw Driver 18 Inches Size Bescom Sr 18-19 Sl No:525 Item Code62.26, 407. Supplying Of Screw Driver 18 Inches Size Bescom Sr 18-19 Sl No:526 Item Code62.27, 408. Supplying Of 8 Inch Screwer Bescom Sr 18-19 Sl No:527 Item Code62.28, 409. Supplying Of Hammer 8 Lbs Bescom Sr 18-19 Sl No:528 Item Code62.29, 410. Supplying Of Hammer 2 Lbs Bescom Sr 18-19 Sl No:529 Item Code62.30, 411. Supplying Of Allen Keys Bescom Sr 18-19 Sl No:530 Item Code62.31, 412. Supplying Of Adjustable Screw Spanner 8 Inches Bescom Sr 18-19 Sl No:531 Item Code62.32, 413. Supplying Of Adjustable Screw Spanner 12Inches Bescom Sr 18-19 Sl No:532 Item Code62.33, 414. Supplying Of Box Spanners Bescom Sr 18-19 Sl No:533 Item Code 62.34, 415. Supplying Of Hand Operated Crimping Tool 25 Sqmm To400 Sqmm Bescom Sr 18-19 Sl No:554 Item Code62.55, 416. Supplying Of Ladder Frp Bescom Sr 18-19 Sl No:554 Item Code62.55, 417. Supplying Of Men At Works Sign Board Bescom Sr 18-19 Sl No:566 Item Code62.67, 418. Supplying Of Insulated Gos Operated Handle /Rod For Redesigned & Modified Bescom Sr 18-19 Sl No:569 Item Code62.70, 419. Supplying Route And Joing Indicating Slab With Ms Anchor Roodbescom Sr 18-19 Sl No:588 Item Code63.19, 420. Supplying Of Black Cambric Tape 25Mm Wide 10Mmm Thick And In Rolls Of 50 Mtrs Bescom Sr 18-19 Sl No:589 Item Code63.20, 421. Supplying Of Yeliow Cambric Tape 25Mm Wide 10Mmm Thick And In Rolls Of 50 Mtrs Bescom Sr 18-19 Sl No:590 Item Code63.21, 422. Supplying Of Cotton Waste Bescom Sr 18-19 Sl No:597 Item Code63.28, 423. Supplying Of Pvc Insulation Tape 19Mm Wide And In Rolls Of 10 Mtrs Bescom Sr 18-19 Sl No:591 Item Code63.22, 424. Supplying Of Hdpe Flexible Poly Barricade Tape Of 50Microns Bescom Sr 18-19 Item Code 62.66, 425. Supplying Of Spike Buster With 5 Mtr 1.5 Sqmm 3 Core Cable, 426. Supplying Of Halogen Lamps 24 Volts 50 Watts For Spot Light, 427. Supplying Of Patient Examination Spot Light With Incandascen Lamp (Complete Set, 428. Supplying Of Patient Examination Spot Light With Led Bulb 22/36 Watts, 429. Supplying Of Lcd Projector Lamp For Epson Make Projector, 430. Supplying Of Lcd Projector Remote Controller, 431. Supplying Of Vga Cable For Lcd Projector 15 Mtrs In Length With Terminal Connector Of About 2 Mtrs Separately, 432. Supplying And Drawing Hdmi Cable For Lcd Projectors 15 Mtrs In Length, 433. Supplying And Installation Of Smf Batteries 65 Ah Foron-Line 60 Kva Ups, 434. Supplying Of 100 Ah Smf Batteries For 80 Kva On Line Ups, 435. Supplying Of 26 Ah Batteries For 5 To 6 Kva On Line Ups, 436. Supplying And Installation Of Generator Set Batteries O180 Ah Exide Express With A Warranty For 2 Years On Exchange Basis Including To And Fro Charges And Labour Charges, 437. Supplying And Installation Of Generator Set Batteries 150 Ah Exide Express With A Warranty For 2 Years On Exchange Basis Including To And Fro Charges And Labour Charges, 438. Supplying And Installation Of Generator Set Batteries 130 Ah Exide Express With A Warranty For 2 Years On Exchange Basis Including To And Fro Charges And Labour Charges, 439. Supplying And Fixing Of Battery Charger For Dg Sets 24 Volt, 440. Supplying And Fixing Of Battery Charger For Dg Sets 12 Volt Overhauling Of Acb, Greasing Etc.. Including All Labour Charges, 441. Supply Installation Testing And Commissioning Of 1000 Kva 11Kv/433V 3 Phase 50 Hz Delta Star Dyn11 Outdoor Natually Cooled Oil Immersed Copper Double Wound Transformer Conforming To Is 1180 1180 3 Level Contained In Mild Steel Radiator Cooled Tank With First Fill Of Oil As Per Is 335 With On Load Tap Changer From Plus5% To 15% In Steps Of 2.5% Remote Tap Changes Panel With Avr Class F Insulation Rating And Diagram Plate Earthing Terminals 2 Nosliffting Lugs Air Release Hole With Plugdehydrating Silica Gel Breatherprismatic Oil Level Guageoil Conservator With Drain Plugthermometer Pocketjacking Lugsbottom Drain Cum Filter Valvetop Filter Valve4 Nos Bidirectional Rollerspressure Relief Devicemarshalling Box [Wherever Applicable]100 Mm Oti/ 150 Mm Oti With Alarm & Tripwti With Alarm And Trip Buchholz Relay With Alarm And Tripshut Off Valves For Buchholz Relaymagnetic Oil Level Guageradiators Fixed / Detachable With Ht & Lt Cable End Boxes / Provison For Lv Bus Duct Type The Transformer Shall Have Suitable Enclosure For Providing Neutral Ct On Earthed Star Point With Connector For Connection To Ref Relay Provided In Main Panel All Routing Test As Per Is Shall Be Conducted On The Transformer The Transformer Enclosure Shall Have Suitably Designed Louvers For Air Circulation & Efficient Cooling Required Danger Boards Signages Lettering Etc The Enclosure Shall Be Epoxy Powder Coated The Transformer Shall Be Subjected To All Routine Tests As Per Is/Iec Standards Type Test Certificate Shall Be Submitted As Per Ec Bc Norms ---- Etc., Complete With All Lead & Lift, As Per Specifications And As Per Directions Of The Engineer In Charge Of The Work Including Supplying And Drawing Lt Ug Cable 400 Sqmm 150 Mtrs, Copper Bus Bar For 2000 Amps , And Lt Feeder Box Comprising 200 Amps Acbsupplying And Fixing And Outgoings 800 Amps Acb 2No,S ,400 Amps Mccb 4 No,S With Necessary Earthing Pits 8 No,S With Copper Plate Earthing Including Construction Of Earth Chambers, Truss Roofing For The Out Door Panel And Complete All Civil Works For Bedding Platform And Out Door Lt Panel As Per The Specifications And As Per The Directions Of The Engineer In Charge Of The Works Make :Kirloskar/ Volt Amp/Equivalent As Approved By Bescom, 442. Supplying , Errection , Testing And Commissioning Of 500 Kva Capacity Copper Wound Distribution Transformere 11Kv/433 Volts With Oltc Bee Star Rated With Ht And Lt End Boxes Including All Standard Accessories Make: Kirloskar, 443. Fixing All Types And All Capacities Of Fluorescent /False Ceiling / Spot Light /Cfl/Led Fittings Indoor On The Wall/Ceiling /Rafters/Girders Using 23/0.0076” Twin Twisted Pvc Insulated Wires , Required No,S Of Round Blocks And Clamps Pg 108 Item 17.7 17.7.1 On Wall/Ceiling/Rafters/Girders, 444. Releasing The Existing Fan Checking , Testing And Installation At The New Place Pg 104 Item 16.9, 445. Releasing The Existing Ftl Fitting All Capacities , Checking , Testing And Installing At New Place Pg 105 Item 16.12, 446. Supplying Of 9 Volt Batteries Duracell, 447. Supplying Of 48 Ah Smf Batteries For 2 Kva On –Line Ups, 448. Supplying Of 1.5 Volts Aa Batteries, 449. Supplying Of “Aaa” 1.5 Volt Batteries, 450. Supplying , Errection , Testing And Commissioning Of Voltage Stabilizers Suitable For 170 Volts To 270 Volts In Put And Load Variation From No –Load To Full Load With Over Load Protection , Spike Suppression , Operating At 0 Degree To 40 Degree Ranges Etc.. Complete Pg 88 Item 12 12..1.2 4 Kva Capacity, 451. Supplying , Errection , Testing And Commissioning Of Voltage Stabilizers Suitable For 170 Volts To 270 Volts In Put And Load Variation From No –Load To Full Load With Over Load Protection , Spike Suppression , Operating At 0 Degree To 40 Degree Ranges Etc.. Complete Pg 88 Item 12 12..1.23 5 Kva Capacity, 452. Supplying Of 1/2 Inch Pop Screws, 453. Supplying Of 1 Inch Pop Screws, 454. Supplying Of 1 1/2 Inch Pop Screws, 455. Supplying Of 1/2 Inch Alluminium Screws, 456. Supplying Of 1 Inch Alluminium Screws, 457. Supplying Of 1 1/2 Inch Alluminium Screws, 458. Supplying Of 1/2 Inch Wood Screws, 459. Supplying Of 1 Inch Wood Screws, 460. Supplying Of 1 1/2 Inch Wood Screws, 461. Supplying Of 8 Mm Ms Blots With 2 Inch Length Along With Washers, 462. Supplying Of 10 Mm Ms Bolts With 2 Inch In Length Along With Washers, 463. Supplying Of 12Mm Ms Bolts With 2 Inch In Length Along With Washers, 464. Supplying Of 8Mm, 1 1/2 Inch In Length Ss Nuts And Bolts, 465. Supplying Of 10Mm, 1 1/2 Inch In Length Ss Nuts And Bolts, 466. Supplying Of 20Mm, 1 1/2 Inch In Length Ss Nuts And Bolts, 467. Supplying Of 20Mm, 2 Inch In Length Ss Nuts And Bolts, 468. Supplying Of Wooden Guttas, 469. Supplying Of Iron Connector For Electric Stoves, 470. Supplying Of Gun Bolts For Electric Stoves, 471. Supplying Of 2 Kw Coil For Electric Stoves ( Round Type) 6 Inches, 472. Supplying Of 2 Kw Coil For Electric Stoves ( Round Type) 7Inches, 473. Supplying Of 2 Kw Electrical Stoves, 474. Supplying Of 15 Feet Ladder Aluminium Industrial Type Make:Bathla, 475. Supplying Of 6 Feet Ladder Aluminium Industrial Type Make:Bathla, 476. Supplying Of Wall Support Ladder With Flat Step 20 Feet Industrial Type, 477. Providing Human Resource Including Electricians On Shift Basis, 478. Supplying Of 1 Kvc On-Line Ups With 30 Minutes, 479. Supplying On-Line Ups 2 Kva With 30 Minutes Back Up, 480. Supplying Of 3 Pin 6 Amps Top``, 481. Supplying Of 16 Amps 3 Pin Top, 482. Supplying And Fixing Of 6 Amps 3 Pin Top, 483. Supplying And Fixing Of 16 Amps 3 Pin Top, 484. Supplying Of Lcd Projector Having Aspect Ratio16:10, Display Resolution 1080P Full Hd, Horizontal And Vertical Resolution 1200 Pixels, Noise Level 37Db, Audio Wattge ,2 Watts And Wattage 298Watts Total Usb Ports:1 No( Hdmi) And 1 No Vga Port, White And Colour Light Output:3400 Lumens, Composite Video Usb2.0 As Hard Ware Interface, Along With Ceiling Mounting Bracket Kit, 10 Mtrs Of Vga Cable And 10 Mtrs Of Hdmi Cable And Screen Size :300 Inhes, 485. Supplying And Fixing Of Lcd Projector Screen 5”X7”, 486. Supplying Of Wired Mic, 487. Supplying Of Uhf Receiver For Audio System, 488. Supplying And Fixing Of Cordless Mic For Audio System,