Tender For Civil Sor For Anakapally Sa And Visakh Sales Area Under Visakh Ro -Surface dressing of the ground including removing small plants, bushes ,vegetation (dia less than 4) and making surface levelled and disposal of rubbish outside HPCLs premises to an unobjectionable place, as directed by the Engineer in Charge, Excavation for foundation upto required depth below existing ground level up to 1.5m in any tyoe odf soil except hard rock. Rate to include dressing the sides and bottom, bailing out of water if encountered, shoring, strutting, backfilling after the construction of foundation, trenches/plinth beam etccompacting by the side of the foundation and disposal of surplus excavated earth within/outside HPCLs premises to an unobjectionable place, as directed by the Engineer in Charge including spreading, watering and compaction, complete. The measurement of the excavation would be based on actual depth of excavation with applicable rate for different depths, Excavation for foundation upto required depth below ground level in any type of soil except hard rock . Rate to include dressing the sides and bottom, bailing out of water if encountered, shoring, strutting, backfilling after the construction of foundation, foundation, trenches/plinth beam etc compacting by the side of the foundation and disposal of surplus excavated earth within/outside HPCLs premises to an unobjectionable place, as directed by the Engineer in Charge including spreading, watering and compaction, complete . The measurement of the excavation would be based on actual depth of excavation with applicable rate for different depths.EXCAVATION IN EARTH BETWEEN 1.5 TO 3 M, Excavation for foundation upto required depth below ground level in any type of soil except hard rock . Rate to include dressing the sides and bottom, bailing out of water if encountered, shoring, strutting, backfilling after the construction of foundation, compacting by the side of the foundation and disposal of surplus excavated earth within/outside HPCLs premises to an unobjectionable place, as directed by the Engineer in Charge including spreading, watering and compaction, complete . The measurement of the excavation would be based on actual depth of excavation with applicable rate for different depths. EXCAVATION IN EARTH BETWEEN 3 TO 4.5, Excavation for foundation upto required in hard rock and excavation shall be done by chiselling / pneumatic drilling or Blasting. Rate to include dressing the sides and bottom, bailing out of water if encountered, shoring, strutting, backfilling after the construction of foundation, compacting by the side of the foundation and disposal of surplus excavated earth within/outside HPCLs premises to an unobjectionable place, as directed by the Engineer in Charge including spreading, watering and compaction, complete . The measurement of the excavation would be based on actual depth of excavation with applicable rate for different depths. EXCAVATION IN HARD ROCK BETWEEN 3 TO 4.5, Supply and filling with Crush Sand as per IS 21116-1980-2 & IS 486:2000 & IS 383.1970 The particle shape is semi rounded or cubical & not flakey or elongated. Dust percentage is strictly controlled 10 - 15% with fineness modulus 2.6 to 3. Supply and filling with Stone Crushed sand of approved quality in layers of 150 mm each including spreading, compacting by hand ramming and watering etc, all complete as per direction of Engg.-In-Charge. compacted thickness only, Supply and filling with clean silver / river sand of approved quality in layers of 150 mm each including spreading, compacting by hand ramming and watering etc, all complete as per direction of Engg.-In-Charge. Measurement basis compacted thickness only, Supplying and filling imported murrum of approved quality in layers not exceeding compacted thickness of 200 mm inclusive spreading, Watering ,ramming, compacting, and if required, rolling and re-rolling with power roller, mechanical compactor of 80 KN to 100 KN capacity to achieve maximum compaction, all complete as per direction of Engg.-In-Charge. The murrum should be excavated from a quarry / mines, free from weeds, grass and other objectionable debris. Measurement basis compacted thickness only. Rate shall include conducting compaction test as per tech spect, Providing and laying PCC 1:2:4 using 20 mm and down size graded stone aggregates including machine mixing, providing formwork if required, placing, compacting by hand ramming, mechanical vibrators, curing etc complete, Providing and laying 60 mm average thickness coping in CC 1:2:4 mix using 6 to 12 mm stone aggregate with 40 mm projection on either side of wall with drip mould. Rate to include 20 mm thick plaster in cm 1:4 for fixing of glass pieces including mixing, providing necessary shuttering, compaction and curing. Thickness of coping at the ends shall be 40 mm and 80 mm at centre, Providing , mixing and placing REINFORCEMENT CEMENT CONCRET 1:1.5:3 mix using 20 mm and down size graded crushed aggregate including providing and fixing necessary plywood /steel shuttering , scaffolding, bracing, machine mixing, compacting by vibrators, curing, hacking the surface to receive plaster etc. complete. Rate shall be exclusive of the cost of steel reinforcement, which will be paid under a separate item. Concrete conforming to relevant specifications of IS 456 - Latest Edn. - FOR ROOF SLAB & CHAJJA, Providing , mixing and placing REINFORCEMENT CEMENT CONCRET 1:1.5:3 mix using 20 mm and down size graded crushed aggregate including providing and fixing necessary plywood /steel shuttering , scaffolding, bracing, machine mixing, compacting by vibrators, curing, hacking the surface to receive plaster etc. complete. Rate shall be exclusive of the cost of steel reinforcement, which will be paid under a separate item. Concrete conforming to relevant specifications of IS 456 - Latest Edn. RCC 1:1.5:3 FOR TOP SLAB OF UG TANK, Providing and laying in position specified grade (Ready Mix Concrete) controlled concrete as per approved mix design for sub-structure (i.e. upto ground level icluding pavement ) and shapes using graded metal with size 20 mm and 12.5 mm. including placing, vibrating, compacting, curing etc. complete as per provisions of the relevant IS codes Rate shall be exclusive of the cost of steel reinforcement, which will be paid under a separate item READY MIX CONCRETE (M-25) FOR :RCC D/way/ Culvert slab/Tank bottom raft/tank top slab as per IS-4926, BRICK MASONRY WORKS :Providing and constructing following brick masonry in CM 1:5 using first quality bricks of Class designation 35 (35 KG / SQCM minimum) and conforming to IS-1077-1986 including providing all openings and projections , raking the joints to 1 cm deep, scaffolding, soaking of bricks in water prior to use and curing etc, REINFORCEMENT STEEL, Providing hollow concrete block (200mm thk) masonary (IS 2572) in cement mortar 1:6 including scaffolding, curing etc. for walls, parapets etc. below and above plinth at all levels, Joints/wall surface prepared either for fair face finish or plastering and including providing concrete, reinforcement and shuttering (where required) at all door and window jambs, openings etc. complete as per specifications. (RCC runners, mullions and transforms shall be measured & paid for separately under Concrete & reinforcement items), Supplying , erecting and fixing in position Pre- fabricated steel structures at all elevations for Canopy using structural steel sections ISMB/ISMC/ISA conforming to IS:2062 , including cutting, welding or bolting, supply of bolts/nuts/washers etc., complete as per drawings including surface preparation and applying one coat of Zinc Phosphate Primer before erection, one coat after erection and two coats of synthetic enamel paint as per specification after erection and all materials and labour complete. ( No welding is permitted at site). The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes and any other consumables required for completing the work. Nutbolts shall not be considered for payment.Theoretical wight of steel sections shall be considered for payment, Supply and fixing concrete tile of approved make of approved shade of 20mm thickness for flooring including providing 20mm thick 1:5 cement mortar bed and a floating coat of neat cement slurry, finishing the joints with white cement mixed with matching colour pigment, cleaning the surface with dilute sulphuric acid etc. Complete. If necessary, surface unevenness shall be filled up with brick ballast manually compacted with watering etc. complete as per instructions of Engg.-In-Charge without extra cost. Basic rate : Not lower than Rs. 500/sqm, ACRYLIC EMULSION PAINT (INTERIOR GRADE) Providing and applying 2 coats ( first coat with brush and final coat with Roller) of Acrylic Emulsion paint of approved make and shade on all surfaces and heights to give an even shade including primer and full putty (J K Cement / Birla White) after thoroughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth etc., all material and labour complete. General specifications/guidelines given under WHITEWASH item also to be followed, as applicable, ALUMINIUM PANELED DOOR : Providing and fixing Powder Coated aluminum section of approved colour having coating thickness of minimum 50 micron & minimum wall thickness of not less than 2 mm, joints mitred and jointed with heavy duty aluminium pressure die cast cleats with fins to match the outer frames and door frames conforming JINDAL sections as specified fully paneled with 9 mm thick pre-laminated 3 layers medium density ( exterior grade) particle board Grade-1, type -II conforming to IS:12823 bonded with phenolformaldehyde synthetic resin of approved brand and manufacturer fixed to shutter with aluminium snap beading and neoprene / PVC gasket / CP Brass /stainless steel screws fixed to the wall with requisite rawl plugs and screw or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top , bottom and sides with requisite PVC/neoprene felt/polysulphide sealant/silicon sealant including hard ware such as tower bolt of 150 mm length from inside and Aluminum handle and Aluminum aldrop of 200 mm length. on both sides, 3 nos. Aluminium hinges of 100 mm length etc all complete as per architectural drawing. Aluminium door section of JINDAL make or equivalent make with the following section : Main frame on all sides - 4700 (20102) -101.6 x 44.45 x 2.5 of weight 1.977 kg/m Shutter vertical frame- 4537 - (19516) 53.7x44.45x2.3 of weight 1.238 kg/m. Shutter top frame - 4540 - (19518) 53.7x44.45x2.3 of weight 1.173 kg/m. Shutter middle frame - 4621 (20014) - 49.91x44.45x3 of weight 1.495 kg/m Shutter bottom frame - 4524 -(19508) 83.5x44.45x3 of weight 2.107 kg/m, aluminium Cast Door handle and Clip - 4420 (19360) - 19x17.3x0.9 of weight 0.124 kg/m. In case of non-availability, approved equivalent make for Al sections is HINDALCO. Approval of Engg.-In-Charge shall be taken before using equivalent sections matching next higher dimensions and weight per running metre without extra cost, TOWEL RAIL Providing and fixing CP brass towel rail of 20 mm dia and 600 mm long including all accessories such as brackets (coloured), fixed and anchoring etc. complete as directed., Providing & fixing followg. size medium duty GI pipes of approved make conforming to IS-1239 laying in open on brick or RCC surface with the help of MS U clamps at every 1 m and at every turn.on the walls/concrete floors,fixing with clamps at every 1m c-c, necessary tees,bends,elbows,plugs,nipples,unions,testing of pipelines for leaks upto a pressure of 6 Kg/sq cm , painting the pipes with hot bitumen, good after piping complete, Providing & fixing followg. size medium duty GI pipes of approved make conforming to IS-1239 laying in open on brick or RCC surface with the help of MS U clamps at every 1 m and at every turn.on the walls/concrete floors,fixing with clamps at every 1m c-c, necessary tees,bends,elbows,plugs,nipples,unions,testing of pipelines for leaks upto a pressure of 6 Kg/sq cm , painting the pipes with hot bitumen, good after piping complete.20MM DIA EXPOSED GI PIPE, supply and laying chlorinated polyvinyl chloride (CPVC) pipes of SDR 11 pipes and SDR 11 fittings applicable for pipes of less than 2 size and SDR 13.5 pipes and Sch. 40 fittings for sizes of 2.5 to 4. Job includes all other accessories including connections, joining ,butt welding etc , complete as per drawings and mfrs recommendations or as directed at site. size -15MM, Providing and constructing inspection chambers with 230mm thick brick masonary in 1:5 cement mortar, excavation, 75mm thick PCC 1:4:8 bed, plastering with neat cement finish etc. complete. incl. CI ( ISI make) Chamber cover CI covers for Chambers / Inspection chambers etc with frame of 600X600 mm nominal size with seal, all materials and labour complete.& angle Frames to support etc complete - 450X450X600MM INSPN. CHAMBERS(Refer attached Drawing), SEPTIC TANK Providing & constructing septic tank of size 1200x2000x1800mm depth with excavation ,PCC1:4:8 100mm thick bed , 345/230mm thick brick masonary wall in CM 1:5 ,RCC1:2:4 100mm thick slab with 8mm tor steel @150c/c both way , 115mm thick baffle wall with RCC beam at bottom ,12mm thick smooth cement plaster with water proofing compound inside and exposed outside portion, providing 600mmx600mm size medium duty CI cover, providing 75mm dia PVC vent pipe etc. Complete.(Refer attached Drawing), Providing and laying point wiring in concealed conduits for the following points using specified 1100V grade PVC insulated, FRLS multistranded 3 x 1.5 sqmm copper conductor wires. Rate to include supplying, laying and securing in position in roof slabs and brick walls or concrete columns 25 mm dia rigid PVC conduits (Conforming to IS 9537:Part 3: 1983) of approved make with necessary accessories and junction boxes/pull boxes. Providing and fixing in the brick walls flush type metal switch boxes of approved make shade and sufficient size to accommodate all 6A Modular switches / 3 pin socket, screws, holders. ceiling roses and the fan regulator wherever required. Rate to include wall chasing and rough plastering. Providing and fixing single pole 6 A socket modular plate switches of approved MK or ANCHOR ROMA/HAVELLS /FINOLEX/CRABTREE/SSK make and of approved colour . One switch shall be provided for each light and fan point. Rate also to include providing main circuit wiring from DB to switch boards with 2 runs of 2.5 sqmm copper wire and 1 run of 1.5 sqmm through PVC conduit. also All wires shall be conforming to IS 694:1990. but for 6A socket controlled by one 6A switch on the same lighting board, Providing and laying point wiring in concealed conduits for the following points using specified 1100V grade PVC insulated, FRLS multistranded 3 x 1.5 sqmm copper conductor wires. Rate to include supplying, laying and securing in position in roof slabs and brick walls or concrete columns 25 mm dia rigid PVC conduits (Conforming to IS 9537:Part 3: 1983) of approved make with necessary accessories and junction boxes/pull boxes.Providing and fixing in the brick walls flush type metal switch boxes of approved make shade and sufficient size to accommodate all 6A Modular switches / 3 pin socket, screws, holders. ceiling roses and the fan regulator wherever required. Rate to include wall chasing and rough plastering.Providing and fixing approved MK or ANCHOR ROMA/HAVELLS /FINOLEX/CRABTREE/SSK make and of approved colour . One switch shall be provided for each light and fan point.Rate also to include providing main circuit wiring from DB to switch boards with 2 runs of 2.5 sqmm copper wire and 1 run of 1.5 sqmm through PVC conduit. also All wires shall be conforming to IS 694:1990. but for 6A socket controlled by one 6A switch on the same lighting board for 6/16A socket controlled by 16A switch independently mounted including providing wiring with 2 runs of 2.5 sqmm and 1 run of 1.5 sqmm PVC insulated copper wire through PVC conduit, Providing and laying point wiring in concealed conduits for the following points using specified 1100V grade PVC insulated, FRLS multistranded 3 x 1.5 sqmm copper conductor wires. Rate to include supplying, laying and securing in position in roof slabs and brick walls or concrete columns 25 mm dia rigid PVC conduits (Conforming to IS 9537:Part 3: 1983) of approved make with necessary accessories and junction boxes/pull boxes.Providing and fixing in the brick walls flush type metal switch boxes of approved make shade and sufficient size to accommodate all 6A Modular switches / 3 pin socket, screws, holders. ceiling roses and the fan regulator wherever required. Rate to include wall chasing and rough plastering.Providing and fixing approved MK or ANCHOR ROMA/HAVELLS /FINOLEX/CRABTREE/SSK make and of approved colour . One switch shall be provided for each light and fan point.Rate also to include providing main circuit wiring from DB to switch boards with 2 runs of 2.5 sqmm copper wire and 1 run of 1.5 sqmm through PVC conduit. also All wires shall be conforming to IS 694:1990. for 6A socket controlled by one 6A switch on the same lighting board Same as above but for for AC point with 2 runs of 4 sqmm (P&N)and 1 run of 2.5 sqmm (earthing) PVC insulated , FRLS multistrand copper cable in 25 mm dia PVC conduict from MCBDB to 20 A powersocket. The conduit shall be partly/fully concealed in all types of wall, ceiling etc complete with all accessories, wiring, termination, connected civil works, rough plastering etc including supply and fixing of 20A industrial socket controlled by 20A SPMCB of MDS/HAVELS make, Supply, laying , and commissioning of wiring using following sizes of PVC insulated , FRLS, unsheathed, multistrand copper wire drawn in PVC conduits. Rate to include supply of 16 GI fish wire, conduits & accessories, wiring, terminations etc complete. All wires shall be conforming to IS 694:1990 and PVC conduits to conforming to IS 9537:Part 3: 1983 -- supply, laying, and commissioning of wiring using 4 runs of 6 sqmm and 1 run of 4 sqmm FRLS multistranded copper wire in 32 mm dia PVC conduit from panel to Distribution boards, Supply,Delivery and Installation of Wall Mounted Panel Board as per the enclosed Single Line Diagram for Retail Outlets( Refer Attached Drg). Party has to supply the panel after approval of the G.A. Supply,Delivery and Installation of Wall Mounted Panel Board as per the enclosed Single Line Diagram for Retail Outlets( Refer Attached Drg). Party has to supply the panel after approval of the G.A. by HPCL. The panel is to be provided with the following and made out of 16 SWG CRCA sheet steel with gland plate made of 14 SWG CRCA with 100 A TPN copper bus bars, interconnections, earthing, powder coating etc complete as per the approved make of materials:Incomer : 2 no. 63A FPC MCB for DG and EB, 1 no 63A 4 pole on load change over switch 1 no. voltmeter with selector switch, 1 no. ammeter with selector switch and with CT (60/5A) 3 nos, 2 set of phase indicating lamp(RYB), Control Fuse with base.Outgoings: 4 nos. 32 A TPC MCB, 1 no. 32 A TP D MCB, 9 nos. 20 A DPC MCB, 1 no. 40 A DP ELCB 30 mA, 15 nos. 10 A SPB MCB, 2 nos. 10 A DPB MCB ,7 nos. 6 A SPBMCB, 1 no. 40 A FP MCB with KMS meter. Capacitor: 10 KVAR. Connections for the outgoings MCBs from the bus bar to be distributed from the R, Y & B phases as indicated in the SLD. Rate to include supply of Copper bus Bar of 100 amps rating, End termination blocks of sufficient quantity for the above cable terminations but not less than 32A connector - 4 nos, 16 A connectors - 50 nos. Input side cable chamber to have 4 nos. of cable entry holes with dummy caps, on the top and bottom respectively (total 8 holes), of 28 mm dia for installation of NFLP glands. Output side cable chamber to have 25 nos. of cable exit holes with dummy caps, on the top and bottom respectively (total 50 holes), of 19mm dia for installation of NFLP glands. The panel should have provision for earthing connection. The fixing lugs of length 6, bent in the shape of L for mounting the panel on the wall etc. complete. Rate includes supply of necessary wiring accessories, busbar connectors etc complete. Panel size to be of minimum 1700mm(L) x 2000 mm (H) X250 mm (D) ( Refer attached GA Drg) Note : TPI of panels at factory as per the approved QAP of HPCL by TPI vendors ( HPCL shall specify third party inspection(TPI) agencies to the vendor) to be done as per the requirement of the HPCL .Rate of MV panel includes the Cost of TPI and Transportation to the site and inclusive all taxes., Filling material with GSB (Granular Sub Base) of 150 mm thick : The GSB shall consists of the following material : 40 to 53MM Size metal : 40%, 40 to 53MM Size metal : 40%, 20 to 40MM size metal 20%, 10 to 20MM size metal 20% and 0 to 10MM size metal 20%. Job shall include supply and filling GSB materials in compacted layers of 150 MM . Payment shall be released on the compacted layer provided by the vendor at site. Compaction shall be carriedout with Power roller of 80 KN to 100 KN capacity Contractor has to obtain necessary clerance from HPCL or its autorised reprensatative for first layer. Only after clearance of 1 st layer,the second layer GSB shall be provided. Job includes all material, watering, and transporation cost of the required to be completed as per the directions of the HPCL, Supply and Providing, testing, commissioning of and giving test of 100 mm dia submersible pump set of 2 HP confirming to IS 8034 and mortor confirming to IS 9283 of approved make alongwith dry run preventor and starter, Supply and installation , testing, commissioining of single phase 1.5 HP jet pump of approved make with starter of approved make, Carrying out geological testing for finalisation of location of borewell by geologist and submission of the report, Supply and installation of 25 mm NB HDPE pipe with GI nipple at both ends. Complete with labour, etc.