| 1 | 1 | Description | | | |
|---|
| 2 | 1.01 | DC Site: HCI Rack server including license (Perpetual) with support (24 Hour x 7 days a week) with a software defined storage of 20 TB(usable) in total. All licensing should be Academic Licensing in the name of Indian Naval Academy (INA) with minimum number of licences. Minimum 72 physical cores (minimum usable 60 cores) comprising all 03 nodes, 2Ghz Processor or above, 256GB RAM per node. | item1 | 3 | Nos\n(Nodes) |
|---|
| 3 | 1.02 | DR Site: HCI Rack Server including license (Perpetual) with support (24 Hour x 7 days a week) with a software defined storage of 20 TB (usable) in total. All licensing should be Academic Licensing in the name of Indian Naval Academy (INA) with minimum number of licences. Minimum 36 physical cores comprising all 03 nodes, 2Ghz Processor or above, 128GB RAM per node. | item2 | 3 | Nos\n(Nodes) |
|---|
| 4 | 1.03 | Witness/ Management node having fibre connectivity (10G) with respective OS and Licenses as per HCI solution, Tower type with Academic Licensing in the name of Indian Naval Academy (INA) with minimum number of licences. | item3 | 1 | Nos. |
|---|
| 5 | 1.04 | Windows server 2016 R2 OS with license down gradable to 2012 R2 with Academic Licensing in the name of Indian Naval Academy (INA). | item4 | 1 | Nos. |
|---|
| 6 | 1.05 | Network Monitoring Software with perpetual licensing for a minimum of 100 switches and nodes and OEM support with Academic Licensing in the name of Indian Naval Academy (INA). | item5 | 1 | Nos. |
|---|
| 7 | 1.06 | DC Site and DR site: Core Switch 48 Port SFP (Supporting 40G/25G/10G/1G) supporting minimum four 40G uplink per core switch. | item6 | 2 | Nos. |
|---|
| 8 | 1.07 | 40G Modules for DC-DR core switches. Single Mode. Minimum 03 per core switch. | item7 | 6 | Nos. |
|---|
| 9 | 1.08 | 10G modules for DC and DR Core switches. Single mode | item8 | 8 | Nos. |
|---|
| 10 | 1.09 | 10G module for DC and DR servers | item9 | 16 | Nos. |
|---|
| 11 | 1.1 | 10 G Module for iSCSI connection to SAN Dell EMC SCV 3020.(Multimode) | item10 | 4 | Nos. |
|---|
| 12 | 1.11 | 1G Modules 1310 nm for connecting DC-DR core switches to existing switches. Single Mode | item11 | 20 | Nos. |
|---|
| 13 | 1.12 | Backup software with license to backup min 5 VMs to existing Dell NX3200 NAS server with Academic Licensing in the name of Indian Naval Academy (INA). | item12 | 1 | Nos. |
|---|
| 14 | 1.13 | vCloud Suite standard (Perpetual) including OEM support (24 Hour x 7 days a week) for HCI nodes with Academic Licensing in the name of Indian Naval Academy (INA) and minimum licensing as applicable. | item13 | 1 | Lump sum |
|---|
| 15 | 1.14 | vCenter Standard (Perpetual) including OEM support (24 Hour x 7 days a week). All licensing should be Academic Licensing in the name of Indian Naval Academy (INA) and minimum licensing as applicable. | item14 | 1 | Nos. |
|---|
| 16 | 1.15 | Racks 42 U with exhaust fans, horizontal and vertical cable managers 1200m x 600m for DC and DR | item15 | 5 | Nos. |
|---|
| 17 | 1.16 | PDU Vertical Server rack type with 12 Ports for DC and DR | item16 | 12 | Nos. |
|---|
| 18 | 1.17 | DR: 10 KVA UPS with 6 hr backup at 80% load with 5 Years Warranty | item17 | 1 | Nos. |
|---|
| 19 | 1.18 | LIU - 48 port, fully loaded with pigtails | item18 | 4 | Nos. |
|---|
| 20 | 1.19 | LIU - 24 port, fully loaded with pigtails | item19 | 5 | Nos. |
|---|
| 21 | 1.2 | LIU - 12 port, fully loaded with pigtails | item20 | 4 | Nos. |
|---|
| 22 | 1.21 | Patch Panel – 24 port loaded with cable manager | item21 | 5 | Nos. |
|---|
| 23 | 1.22 | Cat 6A UTP cable - White colour | item22 | 2 | Box. |
|---|
| 24 | 1.23 | Cat 6A UTP cable - Grey colour | item23 | 5 | Box. |
|---|
| 25 | 1.24 | RJ 45 Jack for Cat 6A (Pack of 100) | item24 | 1 | Box. |
|---|
| 26 | 1.25 | 12 core single mode OS2 gel free fibre cable armoured | item25 | 2500 | Mtrs. |
|---|
| 27 | 1.26 | 48 Core single mode OS1 Fibre | item26 | 200 | Mtrs. |
|---|
| 28 | 1.27 | 24 Core single mode OS1 Fibre | item27 | 100 | Mtrs. |
|---|
| 29 | 1.28 | SC to LC / LC to LC SM Fibre patch cords 10m (LIU to switch connection between racks) | item28 | 15 | Nos. |
|---|
| 30 | 1.29 | SC to LC/LC to LC SM Fibre patch cords 2m (LIU to switch connection within racks) | item29 | 40 | Nos. |
|---|
| 31 | 1.3 | LC to LC SM Fibre patch cords 10 m (for server rack to switch rack connection) | item30 | 10 | Nos. |
|---|
| 32 | 1.31 | LC to LC SM Fibre patch cords 2m (Within switch rack) | item31 | 10 | Nos. |
|---|
| 33 | 1.32 | NVR 32-channel with 4TB Hard disk | item32 | 1 | Nos. |
|---|
| 34 | 1.33 | Camera - Dome 2 MP or above for DC and DR | item33 | 4 | Nos. |
|---|
| 35 | 1.34 | PoE Switch – 8 port for DC and DR | item34 | 2 | Nos. |
|---|
| 36 | 1.35 | Five star rated split AC – 1.5T with timer and stabiliser. | item35 | 2 | Nos. |
|---|
| 37 | 1.36 | Five star rated Tower AC – 2T with timer and stabiliser | item36 | 2 | Nos. |
|---|
| 38 | 1.37 | Temperature Sensor, Humidity Sensor, Smoke Sensor, Fire Alarm, Power Sensor, Emergency lighting.(02 sensors each) for DC and DR | item37 | 2 | Set |
|---|
| 39 | 1.38 | Access Control Biometric card reader with EM lock, exit switch, all allied accessories and 25 nos RFID cards | item38 | 5 | Nos. |
|---|
| 40 | 1.39 | UTM Firewall with five years bundle subscription (Antivirus, Web filter, Threat detection, URL filter, Application filter) with analyser preferably Academic Licencing for INA. | item39 | 1 | Nos. |
|---|
| 41 | 1.4 | Single port I/O Boxes with keystone and faceplate | item40 | 150 | Nos |
|---|
| 42 | 1.41 | Fibre Optic Splicing Closures Min (6 In 1 Out) | item41 | 3 | Nos |
|---|
| 43 | 1.42 | 1U KVM console USB type with min 8 inputs with inbuilt display compatible with all server. | item42 | 3 | Nos |
|---|
| 44 | 1.43 | ISI standard Conduit Pipes min 25 mm/ 32 mm | item43 | 3000 | Mtrs |
|---|
| 45 | 1.44 | Casing and Capping 20 mm | item44 | 300 | Mtrs |
|---|
| 46 | 1.45 | Distribution Box for DC and DR | item45 | 2 | Nos |
|---|
| 47 | 1.46 | MCCB breakers for DC and DR | item46 | 15 | Nos |
|---|
| 48 | 1.47 | Industrial Socket 16A for DC and DR | item47 | 15 | Nos |
|---|
| 49 | 1.48 | Earthing Conductors for DC and DR | item48 | 2 | Nos |
|---|
| 50 | 1.49 | DC/ DR LED Lighting | item49 | 15 | Nos |
|---|
| 51 | 1.5 | Virtual migrations of Ubuntu, Linux and Windows servers from existing server room to new DC including all applications (08 applications) from ESXI 5.7/6.0 to latest version. | item50 | 1 | Job |
|---|
| 52 | 1.51 | (a) Shifting of all network infrastructure (Racks, LIU etc.) from old server room with OTDR testing. Laying of overhead rail for network cabling at DC (20m) using conduit pipes/ cap and case as required with marking using ferrules and other internal cablings as required at DC and DR.\n(b) Fibre laying charges between DC and DR (1800 m), Aryabhatta-414 to Bhaskara-315 (600m) including route marking, splicing fixing and labelling\n(c) Integrating existing SAN storage Dell EMC SCV 3020 as Internal File Storage using iSCSI protocol.\n(d) Configuration and testing of DC-DR and UTM firewall as per customer requirement.\n(e) NUD LAN server migration.\n(f) Integrating existing NAS server DELL NX3200 as backup solution using Ethernet protocol. | item51 | 1 | Job |
|---|
| 53 | 1.52 | (a) Hardening of the existing room with fire rated wall panels, partitioning and raised floor and nitrile insulation for DC and DR. Installation of fire rated steel door for DC, DR and lighting for DC and DR. Painting DC & DR Paint to restore the interior setup as per the surroundings with one coat of primer and two coats of plastic emulsion. The shade for inside and other areas will be decided by the buyer. Installation of GI laying tile ceiling with prelude grid system\n(b) Power cabling with proper earthing from breaker panel to the server racks and network rack with UPS distribution board/MCB for individual rack and final distribution through PDU/MCCB for individual racks. Integration of existing 40KVA UPS with DC and installation of 10 KVA UPS at DR site with wiring, breakers and allied accessories.\n(c) Installation and configuration of access control and surveillance system for DC and DR.\n(d) Installation and configuration of environment monitoring system with temperature, humidity and smoke sensor. | item52 | 1 | Job |
|---|
| 54 | 1.53 | Comprehensive AMC charges for all active and passive components in the entire solution implemented by the vendor during 6th year post completion of warranty. | item53 | 1 | Job |
|---|
| 55 | 1.54 | Comprehensive AMC charges for all active and passive components in the entire solution implemented by the vendor during 7th year post completion of warranty. | item54 | 1 | Job |
|---|