Corrigendum - Supply , Installation , Testing , Commissioning And One Year Operation And Maintenance Of Power Transformer Along With Allied Electrical Equipments Of 11 Kv Electrical Power Distribution Sub-Station For The 124 Mld Capacity Wtps And Cwps . . ., Sonarpur.-West Bengal

Kolkata Metropolitan Development Authority has published Corrigendum - Supply , Installation , Testing , Commissioning And One Year Operation And Maintenance Of Power Transformer Along With Allied Electrical Equipments Of 11 Kv Electrical Power Distribution Sub-Station For The 124 Mld Capacity Wtps And Cwps . . .. Submission Date for this Tender is 11-01-2020. Fire Extinguishers Tenders in Sonarpur. West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

22888271
Corrigendum : Corrigendum - Supply , Installation , Testing , Commissioning And One Year Operation And Maintenance Of Power Transformer Along With Allied Electrical Equipments Of 11 Kv Electrical Power Distribution Sub-Station For The 124 Mld Capacity Wtps And Cwps . . .
Open Tender
Indian
West Bengal
Sonarpur.
11-01-2020

Tender Details

Corrigendum - Supply , Installation , Testing , Commissioning And One Year Operation And Maintenance Of Power Transformer Along With Allied Electrical Equipments Of 11 Kv Electrical Power Distribution Sub-Station For The 124 Mld Capacity Wtps And Cwps . . . - 2 Supply, Delivery At Site And Storage Of 1500 Kva, 11 Kv / 433 V Onan Indoor Type Transformers With Neutral Brought Out As Per Technical Specification And All Accessories Complete 3 Supply, Delivery At Site And Storage Of 4 Panel, 350 Mva Indoor Type H.T. Vacuum Circuit Breaker As Per Specification With All Inter Connection 4 Supply, Delivery At Site And Storage Of Multi Panel 2500 A Mv Switch Board Connected With The Secondary Side Of 1500 Kva Transformers Suitable For Operation At 415 Volt, 3 Phase, 50 Hz Ac System With All Interconnection Complete As Per Specification 5 Supply, Delivery At Site And Storage Of 110 V, 100Ah, Sealed Maintenance Free Battery Comprising Of 55 Nos., 2 Volts Cells With Float And Boost Charger Cum Dcdb 6 Supply, Delivery At Site And Storage Of 440V, 240 Kvar, 12 Stage Automatic Power Factor Improvement Capacitor Bank ( Apfc ) With All Inter Connection Complete Suitable For 415 V, 50 Hz System As Per Specification 7 Supply, Delivery At Site And Storage Of H.T., M.V. & Control Cable As Per Specification & As Follows 8 I ) H.T. Cable 9 From Wbsedcl’S Summation Panel To Incoming Panel Of Ht Switch Gear Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 10 From Ht Switchgear To Two Numbers Of 1500 Kva Transformer Hv Side Terminal Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 11 M.V. Cables / Bus Duct 12 From Two Numbers Of 1500 Kva Transformer Secondary Side To The Two Number Of 2500A Incomers Of Mv Switchboard, Bus Duct & Accessories With Adequate Size Of Aluminium Conductor Complete With Sealing As Per Specification & Direction Of E.I.C. 13 From Each Of The 1600 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-I, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 5 Lengths. 14 From Each Of The 1000 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-2, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 3 Lengths. 15 From 2500 A Substation Mv Switch Board To Battery Charger, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu Conductor, Xlpe Insulated Armoured Cable. 16 From Battery Charger / Dcdb To H.T. Panel At Sub Station, 1.1 Kv Grade, 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 17 From 2500 A Sub-Station Mv Switch Board To Ventilation System, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 18 From 2500 A Substation Mv Switch Board To Lighting Db, 1.1 Kv Grade 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 19 From 2500 A Substation Mv Switch Board To Ht Switchgear, 1.1 Kv Grade 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 20 Control Cable 21 Stranded Copper Conductor Of Various Ratings And Of Suitable Sizes As Per Specification For All Control Circuit And Interlocking Circuits At Substation 22 Supply, Delivery At Site And Storage Of Jointing Materials As Per Specification & As Follows: 23 All H.T Cables Jointing Materials ( Dry Type, Heat Shrink Joint ) 24 All Mv Cables Jointing Materials For Different Cross Sections ( Dry Type ) 25 All Copper Control & Power Cables Jointing Materials For Different Cross Sections ( Dry Type ) 26 N.B :- No Extra Payment Would Be Made If The Length And Diameter Of The Different Sizes Of Cable & Joints Varies On The Higher Side To Meet Up The Requirement Of The Specification And Site Condition. Rates Must Be Quoted Carefully. This Is Also Applicable For All Type Of Cable Joints. 27 Supply & Delivery At Site And Storage Of Earthing Equipment As Per Specification And All The Other Equipments Required To Comply With Latest I.E. Rules 28 Supply, Delivery At Site And Storage Of Fire Extinguishers As Follows: 29 A-B-C Type ( 5 Kg Each ) 30 Co2 Type ( 4.5 Kg Each ) 31 Supply & Delivery At Site And Storage Of Misc. Items Such As Rubber Mats, Shock Treatment Chart, Danger Boards, Sand Buckets, Glow Sign Board Etc. As Per Specification. 32 Supply & Delivery At Site And Storage Of All Luminaries, Fittings, And Fixtures Complete With Necessary Multi-Strand Copper Wires For Inside Lighting Of Substation As Per Specification. 33 Supply & Delivery At Site And Storage Of Lightning Arrestor Along With Earth Strip And Earth Electrodes All Complete As Per Specification And All Other Equipment Required To Comply With Latest I.E. Rules. 34 Supply & Delivery At Site And Storage Of Spare Parts As Per Specification. 35 Part – B ( Installation Part ) 36 Installation At Site Of 1500 Kva, 11 Kv / 433 V Onan Indoor Type Transformers With Neutral Brought Out As Per Technical Specification And All Accessories Complete 37 Installation At Site Of 4 Panel, 350 Mva Indoor Type H.T. Vacuum Circuit Breaker As Per Specification With All Inter Connection 38 Installation At Site Of Multi Panel 2500 A Mv Switch Board Connected With The Secondary Side Of 1500 Kva Transformers Suitable For Operation At 415 Volt, 3 Phase, 50 Hz Ac System With All Interconnection Complete As Per Specification 39 Installation At Site Of 110 V, 100Ah, Sealed Maintenance Free Battery Comprising Of 55 Nos., 2 Volts Cells With Float And Boost Charger Cum Dcdb 40 Installation At Site Of 440V, 240 Kvar, 12 Stage Automatic Power Factor Improvement Capacitor Bank ( Apfc ) With All Inter Connection Complete Suitable For 415 V, 50 Hz System As Per Specification 41 Installation / Laying At Site Of H.T., M.V. & Control Cable As Per Specification & As Follows 42 I ) H.T. Cable 43 From Wbsedcl’S Summation Panel To Incoming Panel Of Ht Switch Gear Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 44 From Ht Switchgear To Two Numbers Of 1500 Kva Transformer Hv Side Terminal Of 11 Kv Grade, 300 Sq Mm Dia, Al Conductor, Xlpe Insulated, Armoured Cable As Per Specification 45 M.V. Cables / Bus Duct 46 From Two Numbers Of 1500 Kva Transformer Secondary Side To The Two Number Of 2500A Incomers Of Mv Switchboard, Bus Duct & Accessories With Adequate Size Of Aluminium Conductor Complete With Sealing As Per Specification & Direction Of E.I.C. 47 From Each Of The 1600 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-I, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 5 Lengths. 48 From Each Of The 1000 A Outgoing Acb Of 2500 A Substation Mv Switchboard To Respective Incoming Acb Of M.V. Panel At Treatment Plant I.E. Mcc-2, 1.1 Kv Grade, 3.5 C, 300 Sq Mm, Al. Conductor, Xlpe Insulated Armoured Cable, 3 Lengths. 49 From 2500 A Substation Mv Switch Board To Battery Charger, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu Conductor, Xlpe Insulated Armoured Cable. 50 From Battery Charger / Dcdb To H.T. Panel At Sub Station, 1.1 Kv Grade, 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 51 From 2500 A Sub-Station Mv Switch Board To Ventilation System, 1.1 Kv Grade, 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 52 From 2500 A Substation Mv Switch Board To Lighting Db, 1.1 Kv Grade 4 C X 6 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 53 From 2500 A Substation Mv Switch Board To Ht Switchgear, 1.1 Kv Grade 3 C X 2.5 Sq Mm Stranded Cu. Conductor, Xlpe Insulated Armoured Cable. 54 Control Cable 55 Stranded Copper Conductor Of Various Ratings And Of Suitable Sizes As Per Specification For All Control Circuit And Interlocking Circuits At Substation 56 Installation At Site Of Jointing Materials As Per Specification & As Follows: 57 All H.T Cables Jointing Materials ( Dry Type, Heat Shrink Joint ) 58 All Mv Cables Jointing Materials For Different Cross Sections ( Dry Type ) 59 All Copper Control & Power Cables Jointing Materials For Different Cross Sections ( Dry Type ) 60 N.B :- No Extra Payment Would Be Made If The Length And Diameter Of The Different Sizes Of Cable & Joints Varies On The Higher Side To Meet Up The Requirement Of The Specification And Site Condition. Rates Must Be Quoted Carefully. This Is Also Applicable For All Type Of Cable Joints. 61 Installation At Site Of Earthing Equipment As Per Specification And All The Other Equipments Required To Comply With Latest I.E. Rules 62 Installation At Site Of Fire Extinguishers As Follows: 63 A-B-C Type ( 5 Kg Each ) 64 Co2 Type ( 4.5 Kg Each ) 65 Installation At Site Of Misc. Items Such As Rubber Mats, Shock Treatment Chart, Danger Boards, Sand Buckets, Glow Sign Board Etc. As Per Specification. 66 Installation At Site Of All Luminaries, Fittings, And Fixtures Complete With Necessary Multi-Strand Copper Wires For Inside Lighting Of Substation As Per Specification. 67 Installation At Site Of Lightning Arrestor Along With Earth Strip And Earth Electrodes All Complete As Per Specification And All Other Equipment Required To Comply With Latest I.E. Rules. 68 Carrying Out Heat Run Of Ht & Mv Equipments, Dehydration Of Transformer Oil And Making Ready All Ht / Mv Equipment For High / Medium Pressure Testing As Per Rule 69 Carrying Out Statutory High Pressure Testing On All Ht Equipment & Medium Pressure Testing On Mv Equipments As Per Specification Including Charges Of Govt. Inspector 70 Charges For Diesel Generator Set / Temporary Power Connection From Wbsedcl / Cesc For Construction Purposes 71 Testing The Whole Installation & Submission Of Test Reports As Per Specification & Direction Of Eic 72 Commissioning The Whole Installation Including Trial Run For 72 Hours On Load Operation As Per Specification & Direction Of Eic 73 Operation & Maintenance Of All Electrical Appliances Installed In The Substation For A Period Of One Year With Adequate Number Of Working Personnel For Round The Clock Operation As Per Requirement And As Per Specification & Direction Of Eic

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-01-2020 3rd corrigendum Date 07-01-2020
2 06-01-2020 4TH CORRIGENDUM Date 11-01-2020

Key Value

Document Fees
Refer document
EMD
INR 400000.0 /-
Tender Value
Refer document