Purchase And Installation Of Generator To Panchayat Office , Supply , Conveyance , Installation , Testing And Commissioning Of Supply , Conveyance , Installation , Testing And Commissioning Of 15Kva D . G . Set With Company Made Acoustic Canopy Confirming To Cpcb Ii Norms Engine Make Of Engine: Cum Mins/ Greaves/ Leyland/ Kirloskar Type Of Engine: Diesel Engine No Of Cylinders: Suitable To Develop The Required Bhp As Per Manufactures Standards Method Of Cooling: Water Cooling ( With Radiator ) Aspiration: Naturally Aspirated Design: Suitable For Generator Set Application Out Put: Bhp Ratings Specified By The Respective Manufactures Capable Of Delivering The Required Power For Alternator Stan Dared Accessories With Diesel Engine Flywheel Housing And Flywheel To Suit Single Bearing Alternator ( Close Coupled Arrangement ) Air Cleaner Radiator With Fan And Fan Guard Fuel Pump Mechanical Governor Fuel Filter Lubricating Oil Filter Residential Type Exhaust Silencer Battery Charger / Generator Electrical Starter Motor 12 V Dc Control Panel The Control Panel Is Manufactured With 14/16 Gauge Crca Sheet And Is Powder Coated For A Weather-Proof , Long Lasting Finish . The Control Panel Consists Of Following Parts: Standard Engine Instrumentation Multi Function Meter Which Measures: Current ( Amps ) Phase Voltages ( V ) Generator Output Frequency ( Hz ) Engine Water Temperature ( Deg . C ) Lube Oil Pressure ( Kg/Cm2 ) And Equipped With Hour Counter Mcb Of Suitable Rating Key Switch Push Button ( Starter ) Led: Battery Charging Alternator Fail Indication Current Transformers Instrument Fuses Duly Wired And Ferrules Safety Controls For Engine Trip For Low Lubricating Oil Pressure Trip For High Water Temperature Providing Necessary Warning Systems And Ther Safeties As Contemplated In Relevant Iss Fuel Pipe Oil Resistant Flexible Hoses Or Ms Pipe As Per Manufactures Requirement For Fuel Line Alternator Make: Kirlosker/Kel/Greaves/Stamford Type: SelfExcited , Self Regulated Through An Avr Capacity: 15Kva/20 Kw At 0 . 8 Pf System Voltage: , 3 Phase415v , 50 Hz Speed: 1500 Rpm Voltage Regulation Band: + 1 . 0 % Voltage Regulation ( Max . ) In Static Conditions Insulation: Class F/H The Alternator Should Confirm To Is 4722 . Mounting Arrangement Engine And Alternator Are Mounted On A Common Ms Fabricated Base Frame With Avm Pads . Fuel Tank Integral Type Fuel Tank Battery Required Number Of Suitable Rated Fully Charged Battery With Leads And Terminals As Required As Per Manufactures Requirements Including With Mode Power To Charge Supply ( Smps ) Acoustic Enclosure The Dg Set Shall Be Supplied Along With Specially Designed , Company Fabricated ( To Be Fabricated In The Same Company From Where The Dg Set Is Delivered ) Acoustic Enclosure To Meet The Stringent Moef/Cpcb Norms Of 75 Dba @ 1M At 75% Load Under Free Field Conditions . Sufficient Space And Clearance Shall Be Maintained Inside The Enclosure To Have Optimum Serviceability . Air Inlet Louvers Specially Designed To Operate At Rated Load . The Enclosure Shall Be With Uv Resistant Powder Coating Capable To Withstand Extreme Environments . Insulation Materials Shall Conform To Is 8183 Specifications For Better Sound Attenuation . Fluid Drains For Lube Oil And Fuel Fuel Filling Point Documents To Be Supplied Engine Manual Spare Parts Book Warranty Certificate Alternator Manual & Test Certificate 1 Set Control Wiring Drawing Installation It Shall Be Installed In The Pr-Constructed Concrete Bed Complying To Relevant Is Standards , Ie Rules And As Per The Direction Of The Departmental Officials Testing And Commissioning The Dg Set Shall Be Tested As Per Relevant Is Standards . The Load Required For Testing Shall Be Made Available At Site By The Selected Agency At His Own Expense . Warranty The Dg Set Shall Be Guaranteed For Three Year From The Date Of Commissioning From Any Defects In Manufacturing . Any Of The Spares/Components Which Are Found To Be Defective During This Period Shall Be Replaced Immediately Free Of Cost . , Providing , Laying And Fixing 80Mm Dia G . I . Pipe ( Medium Class ) Complete With G . I . Fittings For Extending Dg Set Exhaust Etc As Required . , Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump , Dg Set Etc Including Form Work Etc As Required . , Providing And Laying In Position Reinforced Cement Concrete 1 :2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump , Dg Set Etc . Including Form Work Etc . As Required ( Excluding Reinforcement ) . , Steel Reinforcement For Rcc Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete . , Plastering The Wall/Ceiling/Floor Using With Cement Mortar 1:4 , 12Mm Thick One Coat . , Supply Of Hsd ( Actual Amount Will Be Reimbursed On Production Of Original Documents ) , Charges For Conducting Load Test Of 15Kva/12Kw Dg Set , Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1 . 1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required . 4 Core 16 Sq Mm , Supply , Laying And Clamping Of 1 No . Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable , 1 . 1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables , Spacing Of Clamps Not Exceeding 60Cms , Making Good The Damages , Colour Washing Etc . As Required 4 Core 35 Sq Mm With Factory Made Clamp , Supply , Laying And Clamping Of 1 No . Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable , 1 . 1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables , Spacing Of Clamps Not Exceeding 60Cms , Making Good The Damages , Colour Washing Etc . As Required . 4 Core 16 Sq Mm With Factory Made Clamp , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1 . 1 Kv Grade As Required . 4 X 35 Sq . Mm ( 32Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1 . 1 Kv Grade As Required . 4 X 16 Sq . Mm ( 28Mm ) , Supply & Laying Of Dwc Pipe In Ordinary Soil 0 . 75M Below Ground Level Including Excavation 50/38 Mm Or Nearest Size , Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required 6 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing ( Ip 42/43 ) , Supply , Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V , 50 Hz , Ac Supply In The Existing Panel Assembly As Required . 16 A-100A , 16 Ka ( Ics=100%Icu ) , 3 Pole , Current Limiting Type Mccb Having Thermal Setting Range Of 80 - 100% With Thermal Magnetic Release Having Adjustable Ol , Supplying And Fixing 40 Amps To 63 Amps Rating 240/415 Volts , C Curve Triple Pole . , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required , Supplying And Fixing 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections ,