}

Supply Of Medical Instruments & Equipments To Yalburga Tq Under Dho Office Koppal-Karnataka

Government Departments has published Supply Of Medical Instruments & Equipments To Yalburga Tq Under Dho Office Koppal. Submission Date for this Tender is 23-12-2019. Medical Diagnostic x ray Products Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

22825119
Supply Of Medical Instruments & Equipments To Yalburga Tq Under Dho Office Koppal
Open Tender
Indian
Karnataka
23-12-2019

Tender Details

Supply Of Medical Instruments & Equipments To Yalburga Tq Under Dho Office Koppal 1. Dental Flash Autoclave 1.Should Be A Table Top Autoclave For Dental And Ophthalmic Applications 2. Two Automatic Programmes Approx. At 2.2 Bar At 134 Degrees C And 1.1 Bar At 121 Degree C. The Equipment Should Have Automatic Pressure Control Switch Or Automatic Water Control Device To Ensure That The Equipment Does Not Run Dry. 3. Should Have Flash Cycle For Rapid Sterilization And Should Have An Option For Liquid Cycle. 4. Should Have Air Pump For Closed Door Drying. 5. Should Have Rapid Warm Up Facility. Built In Reservoir To Store Water Required To Produce Steam And Used Water Separately For Easy Decantation. 6. The System Should Be Equipped With Required Safety Features. The Door Should Have Double Locking Safety Feature And Should Open Only With Atmospheric Pressure In The Chamber. 7. Should Have Automatic Cut-Off To Prevent Overheating And Cut-Off For Insufficient Water The Machine Should Not Start Without Sufficient Water. 8. Should Have A Minimum Chamber Capacity Of 19 Litres Or Above. 9. Should Have Pressure Display And Temperature Display. 10.Unit Should Function With 200-240Vac 50 Or 60 Hz Input Power Supply. 11.The System Should Comply With National Quality Certification Or International Standards For Sterilization Safety. 12.Following Accessories Should Be Supplied Along With The Equipment. A. 1 Set Of 3 Removable Shelves Stainless Steel. B. 1 Instrument Basket Stainless Steel. C. 1 Set Of 2 Drum For Sterilization Stainless Steel. D. 1 Roll Of Sterilization Indicator. E. 1 Box Paper Sheet 100 Nos Crepe For Sterilization Packs. F. 2 Spare Silicone Gaskets. G. 1 Sets Of Spare Fuses. H. Equipment Should Be Provided With A Line Cord Power Cord Of Acceptable Durability Quality Length And Current Carrying Capacity And Should Be Compatible With Indian Standard Power Socket. 14.Controls Should Be Visible And Clearly Defined. 15.Labels And Markings Should Be Clear And Visible. 16.Should Have Safety Certificate From A Competent Authority Ce Or Fda Us Or Stqc Cb Certificate Or Stqc S Certificate Or Valid Detailed Electrical And Functional Safety Test Report From Ertl. Copy Of The Certificate Or Test Report Shall Be Produced Along With The Technical Bid. 17.Should Have Air Filters. 18.Gaskets Should Be Replaced At Free Of Cost Whenever Required In The Comprehensive Warranty And Cmc Period., 2. Central Oxygen Unit Installation Erection And Testing Installation Of Medical Gas Piping Shall Be Carried Out With Utmost Cleanliness. Only Pipes Fittings And Valves Which Have Been De-Greased And Fittings Brought In Polythene Sealed Bags Shall Be Used At Site. Pipe Fixing Clamps Shall Be Of Nonferrous Or No Deteriorating Plastic Suitable For The Diameter Of The Pipe. All Joints Shall Be Made Of Copper To Copper And Brazed By Silver Brazing Filler Material Without Use Of Any Flux. All Brazing Shall Be Done By Using A Brazing Rod Cp 104 5 Percent Silver Copper Phosphorous Brazing Alloy And Copper To Brass Or Gunmetal Shall Only Be Joints Using Brazing Rod Ag 203 43 Percent Silver Copper Zinc Brazing Alloy Manufactured To En 1044. Inert Gas Welding Technique Should Be Used By Oxygen Free Nitrogen Gas Inside Copper Pipes While Brazing To Avoid Carbon Deposition As Per Specification., 3. Dental Chair Unit 1.Electrically Controlled Dental Chair With All Functional Components Integrated In The Chair 2.Should Have Seamless Upholstery 3.Should Have Multiple Programmes With Independent Up And Down Movement And Back Rest Movement Permit Complete Supine Position Of The Patient 4.Should Have Manufacturers Name Brand Model Electrical Rating Year Of Manufacture Durably Marked On The Equipment And Should Have Iec 60601 1 2 Certificate 5.Should Have Two Step Articulated Head Rest For Comfortable Patient Head Positioning 6.White Led Operating Light With Reflector With At Least Two Intensities And Hands Free Switch On And Off Facility 7.Operating Light Should Have Autoclavable Or Removable Handle 8.Spittoon Should Be Made Of High Finish Porcelain Toughened Glass With Sensor Activated Cup Filler Flush Function 9.Should Have High And Low Vacuum Suction With Auto Start And Stop Functions 10.Chair Side Console Should Have Couplings For Airotor Micromotor 3 Way Syringe With Under Hanging Type Of Chords 11. Micromotor Should Have 1 Istu 1 Direct Drive 12.Stainless Steel Instrument Top 13.Should Have A Led Backlit Radiographic Image Viewer 14.Warranty Period For 2 Years And Comprehensive Cmc For 6 Years After Warranty Period Required Ce Or Iso Or Fda Certification 15.The Model Should Be In The Market For At Least Three Years The Vendor Will Produce The Necessary Proof For Verification In The Technical Bid Accessories. 16.Operator Stool With Five Castors And Backrest 01 No. 17.Water Bottle And Water Treatment Assembly For Spittoon Connection The Other Functions Should Be Connected To The Integrated Water Reservoir Of Treated Or Distilled Water 5 No Bottle To Be Provided., 4. Dental X Ray Machine 1.Radiography Generator Can Be Used Both For Conventional And Digital Intra Oral Dental X Ray. 2.It Should Have High Frequency And Constant Potential Which Enables Concentrated And Very High-Density Radiation Emission, Whatever The Conditions Of Use 3.The Choice Of Voltage Should Be 60 Or 70 Kv And Intensity 4 Or 8Ma. 4.Should Have Extremely Short Exposure Times Minimum 0.02 Sec. Suitable For Digital Radiology With Ccd Cmos Or Phosphor Plate Sensors. 5.The Generator Is Compatible With All Digital Imaging Systems. 6.The Timer Can Control Up To Two Dc Generators. 7.Microprocessor-Controlled Exposure Time Can Be Customised And Programmed. 8.The Control Software Should Automatically Compensate For Variations In Mains Voltage. 9.The Control Panel Manages Exposure Times That Are Perfectly Suited To Digital Imaging From 0.02 To 3.2 Sec. In 23 Stages 10.Should Meet Aerb Atomic Emission Regulatory Board Standard.,

Key Value

Document Fees
INR 550 /-
EMD
INR 1625.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail