Corrigendum - E-Tender For Procurement Of Equipments Of Civil, Mechanical , Electrical Engineering And Basic Science Labs Of Raisen And Lateri Polytechnic Institutes - 2 3 Phase Rlc Load 1 Kw ( Variable ) Rlc Load Consists Of Following : N-Resistive Load 1 Kw:Loading Rheostat 1.5 Kw Three Phase ( Each Phase Of 0.5 Kw ) In 4 Steps. 3Phase Loading Rheostats Is Designed To Be Used As Loads In Electrical Laboratories. High Quality Rheostats Are Mounted Inside The Specially Designed Highly Ventilated Steel Cabinet. Selector Switches Mounted On Bakelite Front Panel For Load Selection. Fitted On Wheels For Easy Movement. Nloading Voltage : 415~440V Ac , 50Hz, 3 Phase Nloading Capacity : 1.5 Kw Three Phase ( 0.5 Kw Each Phase ) Nno Of Steps : 4 ( 125W Each Step ) Nrheostats : High Quality Wound With Constantan Wire ( Nickel - Copper Alloy ) N-Inductive Load 1 Kw, 10 Amp, Three Phase N-Capacitive Load 1 Kw, 10 Amp, Three Phase 3 Rheostat ( 100 Ohms / 5 Amp ) Range: 100 Ohms / 5 Amps Nsize: 18” X 2 1 / 4 “ Double Tube Nmaterial Used : Ncontact ( Double Contact System ) - Laminated Phosphorous Bronze, Nend Bands- Brass Nickled, Nformer- Porcelain Tube Nglide Rod- Brass, Nside Support- Mild Steel Nterminals- 4 Mm Bakelite Embedded With Brass, Nwire- Nichrome Resistance Wire. 4 Rheostat ( 300 Ohms / 2 Amp ) Range: 300 Ohms / 2Amps N24” X 21 / 4 “ Single Tube Nmaterial Used : Ncontact ( Double Contact System ) - Laminated Phosphorous Bronze, Nend Bands- Brass Nickled, Nformer- Porcelain Tube Nglide Rod- Brass, Nside Support- Mild Steel Nterminals- 4 Mm Bakelite Embedded With Brass, Nwire- Nichrome Resistance Wire. 5 Work Bench Electrical With Instruments Work Bench 5Ft X 2.5Ft, Height 2.5Ft With All Metallic Structure Fitted With Wheels With Logging Arrangements, Provided With Drawers With Lock And Key.The Work Bench Is Fitted With The Following Instruments: Na ) 3 Phase Variac, 28A, 0-470V, Nb ) Dso 100Mhz, 2Ch Nc ) Function Generator 25Mhz, Nd ) Dual Dc Regulated Power Supply, 0-30V , 5A Ne ) Digital Multimeter Suitable To Measure Ac / Dc Current, Ac / Dc Voltage, Etc., Nf ) Soldring & De - Soldring Station Ng ) Multifunction Meter To Indicate 3 Phase Voltage, Current, Frequency, Power Factor, Power, Etc. Ninput Supply 415V , Fitted With Tpn Mcb 32A, Output Sockets Of 5 / 15A 6 Function Generator Frequency : 0.5 Hz To 5 Mhz Function Generators With Sine , Square, Triangle, Ttl & Dc, 6 Digit , Auto Ranging 150 Mhz Frequency Counter Namplitude Modulation ( Internal & External ) Ninternal Am Signal Generator 400 Hz / 1 Khz Ndistortion Factor : < 0.5% Ninternal Lin / Log Sweep And External Frequency Modulation Ncmos Output Adjustable From 2 V To 14 V Nbacklit Lcd Display For Modes And Frequency Nmicroprocessor Based Design 7 Anderson Bridge With Inbuilt Digital Null Detector Nin Built Fixed Dc Regulated Power Supply Of ±5V±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Three Set Of Two Decade Dial X ( 10 W & 100W ) . Non Board Four Unknown Inductance & Two Standard Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel Npower Requirement: 220 Vac +10%, 50Hz 8 Schering Bridge With Inbuilt With Digital Null Detector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Ratio Dial “P” & “Q” Each Having 10 W, 100W & 1000W. Non Board Two Decade Dial X ( 0.01 Mf & 0.01Mf ) . Non Board One Variable Gang Capacitor Range Of 25Pf To 500Pf Non Board Six Unknown Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel Npower Requirement : 220 Vac +10%, 50Hz 9 Kelvin Bridge ( Industrial ) With Dc Source & Galvanometer To Measure The Low Value Resistance. Nmultiplier Dial Is Provided On The Front Panel With Ranges X 0.01W, X0.1W, X1w, X10w, X100w. Nstandard Resistance Dial & Slide Wire Dial Are Also Provided On The Front Panel. Ntwo Press Keys Are Provided On The Front Panel Marked As Coarse And Fine. Ncurrent Reversing Switch Is Provided On The Front Panel To Get The Deflection On Left Or Right Nhand Side In A Galvanometer. Nterminals Are Provided On Front Panel To Connect Galvanometer & Dc Source. 10 Kelvin Bridge ( Student ) With Dc Source & Galvanometer One Ratio Box Of 1-1W, 0. 1-0.1W, 0.01-0.01W, 10-10W, 100-100W, For Connection Of Galvanometer. None Decade Dial Of X0.01W. Nslide Wire Of Resistance 0.05W With Scale Of 100 Equal Divisions. Nfour Terminals For Connecting Unknown Resistance Wire. Ntwo Terminals Are Provided For Battery. 11 Maxwell Inductance Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator Multiplier Dial Is Provided On The Front Panel With Ranges X 0.01W, X0.1W, X1w, X10w, X100w. Nstandard Resistance Dial & Slide Wire Dial Are Also Provided On The Front Panel. Two Press Keys Are Provided On The Front Panel Marked As Coarse And Fine.Current Reversing Switch Is Provided On The Front Panel To Get The Deflection On Left Or Right, Hand Side In A Galvanometer. Nterminals Are Provided On Front Panel To Connect Galvanometer & Dc Source. N 12 Weins Bridge ( Capacity Measurement ) With Inbuilt Digital Null Ndetector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V , ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 1W & 10W ) . Non Board Six Unknown Capacitor & Two Capacitor ( 0.033Mf & 1Mf ) Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz N 13 Weins Bridge ( Frequency Measurement ) With Digital Null Detector With Analog Function Generator 1Hz To 200Khz Nin Built Fixed Dc Regulated Power Supply Of ±5V & +5V / 500Ma. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 0.01Mf& 0.1Mf ) . Non Board Three Decade Dial X ( 10 W , 100W & 1000W ) . Non Board Three Decade Dial X ( 1W , 10W & 100W ) . Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz N 14 Desauty Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator Nin Built Fixed Dc Regulated Power Supply Of ±5V, ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Set Of Two Decade Dial X ( 10W & 100W ) . Non Board One Decade Dial X ( 0.1Mf ) . Non Board Six Unknown Capacitor Are Mounted Behind The Front Panel With Connections Are Brought Out On Front Panel. Nbakelite Used As Front Panel Of 400Mm X 225Mm & Mounted On Light Weight Shock Proof Plastic Cabinet. Ncircuit Diagram Of Discrete Component Printed & All Important Connection Are Brought Out On Front Panel. Npower Requirement : 220 Vac +10%, 50Hz 15 Hays Bridge With Inbuilt Digital Null Detector, Sinewave Oscillator In Built Fixed Dc Regulated Power Supply Of ±5V, ±12V & +5V / 500Ma. Ninbuilt Sine Wave Oscillator, Frequency 1Khz ±3%, Amplitude 0-15Vpp. Nin Built 3½ Digit Digital Null Detector Used As Detector Non Board Two Decade Dial X ( 100 W & 1000W ) . Non Board Three Decade Dial X ( 10W, 100W & 1000W ) . Non Board Two Decade Dial X ( 0.01Mf & 0.1Mf ) . 16 Owens Bridge Owens Bridge With Decade Inductance Box With Sine Wave Oscillator & Decade Inductance Box With Sine Wave Oscillator & Inductance & Sensitive Head Phone 17 Idmt Over Current Relay Testing Kit Relay Type : Over Current Relay Idmt ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 18 Earth Fault Realy Testing Kit ( Electromechanical Type ) Relay Type : Earth Fault Relay Idmt ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N0001sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm, Switches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 19 Percentage Bias Differential Relay Testing Kit ( Electromechanical Type ) Nrelay Type : Percentage Biased Differential Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Rheostats To Set The Biased Current & To Vary The Differential Current Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps, 2Nos. Ac Current Nmeters 0 – 50Amps & 1 No. Ndigital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Nphantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz N 20 Transformer Protection Using Percentage Biased Diffrential Relay N ( Microprocessor Type ) Relay Type : Percentage Biased Diffrential Mib 202 Relay Nterminals : 4Mm Terminals For Rheostats To Set The Biased Current & To Vary The Differential Current Nmeters ( Digital ) : 2Nos. Ac Current Meter 0 – 20Amps, & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mmx48mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Createphantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 900Mm X 600Mm Npower Requirement : 420Vac +10%, 50Hz N N 21 Thermal Over Load Relay Testing Kit Relay Type : Thermal Relay Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 22 Over Voltage Relay Testing Kit ( Electromechanical Type ) Relay Type : Over Voltage Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Voltage Output And Input Nmeters ( Digital ) : 1No. Ac Voltmeter Meter 0 – 300V & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Nvoltage Injector : Inbuilt Variable Voltage Injector 250V To Create Fault Voltage Nindicators : Provided On Front Panel For Mains, Voltage, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz 23 Under Voltage Relay Testing Kit ( Electromechanical Type ) Relay Type: Under Voltage Relay ( Electromechanical Induction Disc Type ) Nterminals: 4Mm Terminals For Trip, Voltage Output And Input Nmeters ( Digital ) : 1No. Ac Voltmeter Meter 0 – 300V & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Nvoltage Injector : Inbuilt Variable Voltage Injector 250V To Create Fault Voltage Nindicators : Provided On Front Panel For Mains, Voltage, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) Nrelay Circuit Diagram : Screen Printed On Front Panel Size 700Mm X 400Mm Npower Requirement : 220Vac +10%, 50Hz N 24 Over Current Relay ( Directional Type ) Testing Kit N ( Electromechanical Type ) Relay Type : Directional Over Current Relay ( Electromechanical Induction Disc Type ) Nterminals : 4Mm Terminals For Trip, Current Output And Input Nmeters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer N.0001Sec. To 9999Sec. ( Auto ) ( 96Mm X 48 Mm ) Ncurrent Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current Nindicators : Provided On Front Panel For Mains, Current, Trip And Alarm Nswitches : Provided On Front Panel For Mains, Timer Reset, Test Switch N ( On / Off ) Nreversing Switch : To Reverse The Direction Of Current Nrelay Circuit Diagram : Screen Printed On Front Panel Npower Requirement : 220Vac +10%, 50Hz N N 25 Advance Plc Trainer Kit Nrs Logic 1000 / Licensed Software : Digital & Analog , Digital 16 Input 8 Output , Analog 8 Input 8 Output, Delta Based Plc Provided With Rs232 Serial Port For Pc Interfacing 26 Simens Tia Module S7-1200 / Licensed Software 27 Plc Control Panel 28 Interfacing Modules For Above Mentioned Plc Trainer 29 Module For Traffic Light Control 30 Module For Dol Starter Control 31 Module For Star Delta Starter Control 32 Module For Conveyer Belt Control 33 Module For Dc Motor Start, Stop Function 34 Module For Water Level Control 35 Module For Temperature Control 36 Module For Sequence Control 37 Module For Elevator Control 38 Scada Software:- Allean Bradely 39 Scada Software:- Wonderware Intuch Student Version :-Simens 40 Module For Elevator Control 41 Anchor Insulated Copper Pvc Cable 2.5 Sq Mm Wire ( 100M ) 42 3 / 20 Swg ( Phase Wiring ) ( 100M ) 43 3 / 22 Swg ( Neutral Wire ) ( 100M ) 44 6 Amp. Modular Switch Board 45 Two Way Switch ( 10 Amp ) 46 One Way Modular Switch ( 10 Amp ) 47 Lamp Holders 48 40W Bulb 3 Pvc Casing 49 Mcb ( 10 Amp ) 50 Fuses ( 10 Amp ) 51 Magic Power Bc-A6 10A Battery Charger 52 Battery Eliminator 53 Electrical Testing Panel 54 Lux Meter Lux Range: 2000, 20000, 50000Lux Nmax. Resolution: 1Lux Nbasic Accuracy: ±5% Fs Nfast Response: 0.2S Nslow Response: 0.4S Ncosine & Color Corrected, Analog Output, Monitor Light Levels Using Outputs; N1mv Per Count Analog Output For Capturing Readings To A Recorder, Supplied With Batteries, Light Sensor, Cable & Protective Cover 55 Smps Trainer Kit Switched Mode Power Supply ( Smps ) Using High Frequency Transformer & High Switching Transistor Has Been Designed To Study The Line And Load Regulation Characteristics Of Smps Power Supplies. Nrotary Switch For Selections Of Different Input Voltage & Linearity Coil For Ac Filtrations , Bridge Rectifier To Convert Ac Into Dc Ndc Filtrations Circuit Is Given To Filter The Impurities I.E. Ac Components. Nhigh Frequency Transformer And High Frequency Transistor ( Bu 508 ) For Switching Action. Nfeed Back / Comparator Circuit To Maintain Output Voltage Constant I.E. +10 % On Load. Two Meters Are Provided On The Front Panel To Measure The Dc Voltage & Current. Two Bulb Holder Are Mounted On The Front Panel To Connect Resistive ( Bulb ) Load Across The Output. Nblock Diagram Printed On Front Panel & Test Points Brought Out On Front Panel. Npower Requirement: 230 Vac +10%, 50Hz. 56 Ups Trainer Kit ( 500 Va ) • On Board Controller Pcb N• On Board Input / Output Transformer & Chargeable Battery N• Digital Panel Meter For Current Reading N• 5 Test Points Provided On Front Panel Only For Observations N• 5 Fault Switch Provided On Front Panel For Fault Creation N• Led Indicators For Status Mode N• Power Requirement: 220Vac+10%, 50Hz 57 Transformer Oil Testing Kit ( 0-80Kv ) Motorized With Digital Display Ninput : 230V Ac, Single Phase. Noutput : 0 –80 Kv, Center Tap Earthed, Ncapacity : 1 Kva Nindication: Mains ‘On And ‘Ht’ ‘On’ Indicating Lamps. Nmetering : 96 Sq. Mm. Size Back Of Panel Mounting, Moving Coil Rectifier Type 0-80Kv Analog Voltmeter Or Trms Digital Voltmeter To Monitor Output Voltage. Nprotection : Electronic Fast Acting Over Current Tripping Device Sensing Ht Current Directly. Nmotorisation : The Unit Will Be Supplied With The Rate Of Rise Of Voltage @ 2Kv / Second And In Case Of Motorization Failure, The Unit Can Be Operated Manually. Naccessories :Acrylic Oil Cup With Electrodes, Gauge, 3 Pin Mains Top. 58 Digital Earth Tester With Kit N4 Terminal Type Ndisplay 3 Digit Lcd Nrange: 10 Ohms & 1000 Ohms Nterminals: 4 Mm Screw Type Nmains Cum Battery Operated