}

Purchase Of Reagents/Kits And Consumable Items For Neruobio Chemistry Lab On Two Years Rate Contract Basis., CNC AIIMS, NEW DELHI-Delhi

All India Institute Of Medical Sciences has published Purchase Of Reagents/Kits And Consumable Items For Neruobio Chemistry Lab On Two Years Rate Contract Basis.. Submission Date for this Tender is 03-12-2019. Cutting Crimping and Punching Tools Tenders in CNC AIIMS, NEW DELHI Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

22395706
Purchase Of Reagents/Kits And Consumable Items For Neruobio Chemistry Lab On Two Years Rate Contract Basis.
National Competitive Bid
Indian
Delhi
Cnc Aiims, New Delhi
03-12-2019

Tender Details

Purchase Of Reagents / Kits And Consumable Items For Neruobio Chemistry Lab On Two Years Rate Contract Basis. - 2 Vsd Ring Adult & Child N N• Should Be Available In Adult Size: ( 35Cm Outer Ring And 20Cm Inner Ring With The Circular Opening Of Size 10Cm ) And Pediatric Size: ( 30Cmx20cmx10cm ) N• Should Be Made Of Medical Grade Cotton Cloth ( High Quality Linen ) N• Cloth Should Be Preferably White Coloured So That Suture Can Be Clearly Traced N• Should Be Eto Sterilized N• There Should Be High Quality Stitching Of Margin Of Cloths ( Doubly Stitched Without Any Loose Hanging Threads ) N• Should Provide Samples For Final Physical Verification And Approval N 3 Surgical Clipper Blade N N• Should Enable High Efficiency Surgical Hair Removal In Minimum Passes And Minimum Trauma To Skin N• Should Have Ergonomic Design To Handle Curved Areas On The Body N• Should Be Sterlisable ( Eto Or Cidex Solutions ) The Assembly Should Be Robust To Handle Submersion In Disinfectant Solutions. N• Energy Source - Should Be Rechargeable Or Should Come With Slots For Easily Available Batteries. N• Clipper Should Be Compatible With All Standard Surgical Clipper Blade Or Should Supply Blades. N Nshould Provide Samples For Final Physical Verification And Approval N 4 Bovine Pericardial Patch-All Sizes N• It Should Flexible For Ease Of Suturing N• It Should Be Easy To Handle N• Should Be Ready To Use Fact With Minimum Rinse Time N• Patch Thickness Range 0.4-0.6 Mm N• Should Have Construction Such That It Aligns Well To Various Heart Counours N• Should Be Hemostatic To Minimize Perioperative Patch-Related Bleeding N 5 Cell Saver Kit N N• Should Be One-Stop Complete Kit Of Disposables For Collection, Washing, Filtering, Processing And Storage Of Blood Collected From Patient N• Should Be Compatible With Current Available Hardware ( Cell Saver System ) In Ctvs Department ( Bidding Vendor May Inspect The Machine Before Quoting ) N• The Disposable Kit Should Include Suction-Anticoagulant Line, Waste Saline Collection Bag, Filter Cone, Blood Collection Bag, Connectors And Prime Ports. N 6 Internal Mammary Artery Needle ( Arteriotomy Cannula ) N N• The Lumen Should Be Of 1 Mm Or Less Only. N• The Length Should Be Of In The Range Of 1.5-2.5 Inches. N• The Shaft Should Be Made Of Medical Grade Stainless Steel. N• The Tip Of Cannula Should Be Bulbous And Atraumatic. N• The Cannula Should End With Female Leur Fitting: Which Can Be Attached To Any Regular 5Ml Or 10Ml Syringe. N• Should Provide Sample For Final Physical Verification And Approval. N• Electro Surgical Ground Pad. N 7 Soft Pd Catheter Adult N Ncomplete Kit Should Be Available With One Set. N• Kit Should Have Soft Pd Catheter, Clamp, Adapter, Guidewire, Syringe, Introducer Needle, Tunneling Stylet, Surgical Blade. N• Two Cuffs Should Be Available In The Pd Catheter ( Preperitoneal And Subcutaneous ) N• The Catheter Material Should Be Soft And Non-Irritant For Prolonged Placement In Peritoneal Cavity Without Causing Adhesions Or Erosions. N• Adult Catheter Total Length: 40-60Cms. N• Should Have A Radio Opaque Stripe On One Side. N 8 Soft Pd Catheter , Pediatric N N• Complete Kit Should Be Available With One Set. N• Kit Should Have Soft Pd Catheter, Clamp, Adapter, Guidewire, Syringe, Introducer Needle, Tunneling Stylet, Surgical Blade. N• Two Cuffs Should Be Available In The Pd Catheter ( Preperitoneal And Subcutaneous ) N• The Catheter Material Should Be Soft And Non-Irritant For Prolonged Placement In Peritoneal Cavity Without Causing Adhesions Or Erosions. N• Adult Catheter Total Length: 40-60Cms. N• Pediatric Catheter Total Length: 20-40Cms. N• Should Have A Radio Opaque Stripe On One Side. 9 Soft Pd Catheter , Neonatal N N• Complete Kit Should Be Available With One Set. N• Kit Should Have Soft Pd Catheter, Clamp, Adapter, Guidewire, Syringe, Introducer Needle, Tunneling Stylet, Surgical Blade. N• Two Cuffs Should Be Available In The Pd Catheter ( Preperitoneal And Subcutaneous ) N• The Catheter Material Should Be Soft And Non-Irritant For Prolonged Placement In Peritoneal Cavity Without Causing Adhesions Or Erosions. N• Should Have A Radio Opaque Stripe On One Side. N 10 Haemodialysis Kit For Adult ( Supplied As One Pack ) N• Should Have Double Lumen Catheter 11.5 Fr. N• Polysulfone Dialyzer. N• Av Tubing. N• Haemodialysis Fluid 5L. N• Bicarbonate Powder As Required For Dialysis For One Adult. 11 Urometer 250 Ml N N• Should Be Made Of High Quality Medical Grade Material, Packaged In A Sterile Pouch. N• Should Have Clear And Transparent Graduated Volume Meter For Pediatric Patients For Hourly Accurate Measurement Of The Urine Output. N• Should Be Connected To A Urobag Having Capacity Of Minimum 1 Litre. N• Should Have Underside Drainage Port For Sampling And Drainage. N• Should Be Closed Circuit Drainage To Eliminate Infection Risk. N• Should Have Soft, Kink Resistant Tubing. N• Should Have A Universal Tapered Connector For Secure Connection With The Uretheral Catheter. N• Should Have A Foldable Hook And Tube Holder For Bed Side Hanging. N 12 Urometer 500 Ml N N• Should Be Made Of High Quality Medical Grade Material, Packaged In A Sterile Pouch. N• Should Have Clear And Transparent Graduated Volume Meter For Adult Patients For Hourly Accurate Measurement Of The Urine Output. N• Should Be Connected To A Urobag Having Capacity Of Minimum 1.5 Litre. N• Should Have Underside Drainage Port For Sampling And Drainage. N• Should Be Closed Circuit Drainage To Eliminate Infection Risk. N• Should Have Soft, Kink Resistant Tubing. N• Should Have A Universal Tapered Connector For Secure Connection With The Uretheral Catheter. N• Should Have Foldable Hook And Tube Holder For Bed Side Hanging. 13 Custom Tubing Pack For Cardiopulmonary By Pass-Adult Without Arterial Filter N N• Should Be Local Fda – Drug License For Manufacturing. N• Should Be Supplied Sterile And Non-Pyrogenic. N• Should Be Iso 9001:2008, Iso 1348: 2003 Certified Manufacturer. N• Tubing Material Should Be Imported Usp Class Vi Implant Tested Transparent Pvc. N• Tubing Hardness Should Be 68 + / - Shore A. N• Port Material Should Be Polycarbonate. 14 Invasive Arterial Catheter For Bp Monitoring ( 22G Length: 7 To 8 Cm ) N N• Should Be Made Of High Quality Medical Grade, Non-Irratant Material For Long Dwelling Placement. N• Should Have Complete Kit Arrangement For Sterile Placement By Seldinger Technique. N• Should Have A Stainless Steel Introducer And Soft Guidewire. N• Should Have Luer Lock-Fitting Mechanism. N• Should Have A Radio Opaque Line. 15 Invasive Arterial Catheter For Bp Monitoring ( 20G Length: 8 To 10 Cm ) N N• Should Be Made Of High Quality Medical Grade, Non-Irratant Material For Long Dwelling Placement. N• Should Have Complete Kit Arrangement For Sterile Placement By Seldinger Technique. N• Should Have A Stainless Steel Introducer And Soft Guidewire. N• Should Have Luer Lock-Fitting Mechanism. N• Should Have A Radio Opaque Line. 16 Invasive Arterial Catheter For Bp Monitoring ( 18G & 16G Length: 10-15 Cm ) N N• Should Be Made Of High Quality Medical Grade, Non-Irratant Material For Long Dwelling Placement. N• Should Have Complete Kit Arrangement For Sterile Placement By Seldinger Technique. N• Should Have A Stainless Steel Introducer And Soft Guidewire. N• Should Have Luer Lock-Fitting Mechanism. N• Should Have A Radio Opaque Line. 17 Reusable Electrosurgical Grounding Pad N N• Should Be Made Of Akton Foam. N• Should Feature Current Limiting Nature & Hence Completely Eliminate Patient Pad Site Burns. N• Should Be Based On Capacitive Coupling Principle. N• The Pad Should Be Such That It Should Not Come In Direct Contact With Patients But Still Safely Exit Current Back To The Generator. N• Should Be Radiolucent & Latex Free. N• Reusable Upto Two Years. N• The Manufacturer Should Provide Written Guarantee That No Patient Pad Site Burns Will Occur Within The Expiry Date On The Pad. N• Should Be Us Fda Approved. N• Should Be Made Compatible To Any Electrosurgical Generator. N• Size: Adult: 46”L X 20”W X ½’ Thickness Npaed: 26” L X 12’ W X ½” Thickness Nuniversal Size: 36”L X 20”W X 1 / 8”Thickness 18 Pediatric Tracheostomy Tube Without Cuff ( 3Mm To 5Mm ) N N• Should Be Made Of High Quality Grade Material To Minimize Skin Irritation Over Long Placement Duration. N• Material Should Be Soft To Adjust To Individual Patient Anatomy And Minimize Trauma During Insertion / Removal. N• Should Have Soft, Flexible Transparent Flanges For Easy Fixation And Underlying Skin Visibility. N• Should Have Standard Connector For Attachment To T Piece / Ventilator Breathing System. N• Should Have Radio Opaque Line. N• Kit Should Have Non Irritant Neck Tape For Fixation. 19 Pediatric Tracheostomy Tube With Cuff ( 3Mm To 5Mm ) N N• Should Be Made Of High Quality Grade Material To Minimize Skin Irritation Over Long Placement Duration. N• Material Should Be Soft To Adjust To Individual Patient Anatomy And Minimize Trauma During Insertion / Removal. N• Should Have Soft Seal Cuff To Minimize Air Leak And Prevent Tracheal Injury. N• Should Have Soft, Flexible Transparent Flanges For Easy Fixation And Underlying Skin Visibility. N• Should Have Standard Connector For Attachment To T Piece / Ventilator Breathing System. N• Should Have Radio Opaque Line. N• Kit Should Have Non Irritant Neck Tape For Fixation. N 20 Liquid Nitrogen Gas - N N• Supplier Should Ensure High Purity Medical Grade Liquid Nitrogen Stored In Safe And Standard Containers. N• The Containers Should Ensure Maximum Coolant Retention. N• Nitrogen Pressure At 21 Degrees Celsius Should Be In The Range Of 1900-2300 Psi. N• Should Be Available In Standard Cylinder Size Which Can Be Easily Emptied Into Nitrogen Storage Tanks In Our Valve Bank Facility. Nsupplier Should Ensure Fast ( Within 48 Hours ) And Consistent Supply Of Nitrogen Cylinders On A Requirement Notice From The Department 21 Carotid Artery Loop Shunt All Sizes: N N• Should Be Packaged In Sterile Easy Peel – Off Wrapper ( Double Wrap, Pyrogen Free Packing ) . N• Should Be Available In Various Adult Sizes. N• Should Be Constructed Of High Quality Silicon With Metallic Wiring To Prevent Kinking Or Occlusion. N• The Ends Of Shunt Should Be Bulbous For Easy Placement And Retention In Carotid Vessel. N• Should Be Available In Small, Medium And Large Diameter Sizes. N• Length 10-30Cm. 22 Axillary Artery One Piece Cannula With Central Arterial Pressure Measurement N N• Sizes 18 Fr. - 24Fr. N• Should Have Elongated One Piece Wire Wound Body With Radio Opaque Suture Ring And Dilator With Depth Markings. N• Should Have Integrated Pressure Monitoring Port At Tip. 23 Distal Arterial Perfusion Cannula N N• Should Be Made Of High Grade Natural Rubber Latex / Equivalent. N• Diameter Ranges 11-14 Fr. N• Should Have A Distal Easily Inflatable Latex Balloon. N• Color Coding Of Two Stop Cock ( Balloon Inflation And Blood Flow Control ) Should Be There. N• Should Be Packaged In Sterile Non Pyrogenic, Easy Peel – Off Packing. 24 Aortic Arch Perfusion Cannula N N• Should Be Long And Flexible. N• Should Have Wire Reinforcement. N• Should Have An Obturator For Easy Distalmost Arch Cannulation . 25 Aortic Perfusion Cannula Sizes: 10, 12, 14, 16, 18, 21, 24, 26 Fr / Ch N N• Should Have Smooth Bevelled Tip. N• Should Be Long And Flexible. N• Cannula Should Be Clear For Good Visibility N• Should Have An Indicator Coloured Line For Proper Placement 26 Balloon Tip Antegrade Cerebral Perfusion Cannula N N• Should Be Highly Flexible But Kink Resistant. N• Should Have A Soft Latex Inflatable Balloon Near Tip To Ensure Unidirectional Blood Flow And Prevent Displacement / Blood Leaks. N• Should Be Available In A Range Of Sizes 8 French-14 French 27 Teflon Hard Felt: N N• Should Be Made Of High Quality Fabric To Ensure Accurate Homeostasis. N• Thickness 2-3 Mm To Provide Adequate Strength To Tissue. N• Sizes:- 4”X4” & 6”X6” 28 E-Ptfe Stretch Large Diameter Aortic Vascular Graft Of Diameter And Length As Under. Na. 20Mm X 28 Cm 29 E-Ptfe Stretch Large Diameter Aortic Vascular Graft Of Diameter And Length As Under. Nb. 20Mm X 30 Cm 30 E-Ptfe Stretch Large Diameter Aortic Vascular Graft Of Diameter And Length As Under. Nc. 24Mm X 20 Cm 31 E-Ptfe Stretch Large Diameter Aortic Vascular Graft Of Diameter And Length As Under. Nd. 22Mm X 20 Cm 32 E-Ptfe Stretch Large Diameter Aortic Vascular Graft Of Diameter And Length As Under. Ne. 22Mm X 30 Cm 33 E-Ptfe Stretch Large Diameter Aortic Vascular Graft Of Diameter And Length As Under. Nf. 24Mm X 30 Cm 34 Snugger Set – All Sizes: N N• Three Pairs Of Smooth Snugger With Yellow, Blue & Pink Colors For Vessel Identification. N• Each Snare Set Consists Of Thumb Holder Handle For Easy Maneurability. N• Specially Designed For Putting Purse String Sutures, N• Made Of Medical Grade Pvc. N• Sizes Adult & Pediatric. 35 Suprapubic Catheter With Trocar N N• Used For Cystostomy And Supra-Pubic Drainage. N• Manufactured From 100% Silicone, Non-Toxic And Non-Irritant. N• Symmetrical Inflated Balloon Provided For Self Retention. N• Radio-Opaque Line Throughout Its Length For X-Ray Visualization. N• One Lateral Eye At Distal End For Efficient Drainage. N• Sterile, Individually Packed In Box. N• Sizes: 16, 18, 20, 22 Fg 36 Gravity Bag N N• 1200 Ml Capacity Bag For Feeding Purpose. N• Ice Pouch Provided With The Bag For Preserving The Food For Longer Period. N• Transfer Set Directly Connected To The Bag For Easy Feeding. N• Roller Controller Is Provided To Control The Flow. A Hanger Is Provided With Bag For Easy Handling. N• Sterile, Individually Packed In Peelable Pouch. 37 Centrifugal Pump Disposable Cone – Adult N N• Should Be Compatible ( Without Adapter ) With The Existing Medtronic / Sarns / Terumo Pump Machine Available In The Department. Budding Vendor May Inspect The Machine Before Quoting. N• Should Work Within A Low Prime Volume ( 40-80 Ml ) . N• Should Hav 3 / 8 Inch Inlet Outlet. N• Flow Range 0.1 – 9 Litre / Min. N• Rotation Range 0-3600Rpm. N• Low Heat Generation Created By Fewer Moving Parts And Ceramic Pivot Bearing. N• Should Have Biocompatible Internal Surfaces Causing Low Hemolysis. N• Interested Bidder Is Required To Make A Demonstration Before Bidding. N 38 Centrifugal Pump Disposable Cone Pediatric N N• Should Be Compatible ( Without Adapter ) With The Existing Medtronic / Sarns / Terumo Pump Machine Available In The Department. Bidding Vendor May Inspect The Machine Before Quoting. N• Should Work Within A Low Prime Volume ( 40-80 Ml ) N• Should Have 1 / 4Th Inch Inlet Outlet N• Flow Range 0.1 – 6 Litre / Min N• Rotation Range 0-3600 Rpm N• Low Heat Generation Created By Fewer Moving Parts And Ceramic Pivot Bearing. N• Low Impact With Even Blood Flow, Low Shear And No Stagnant Blood Zones N• Should Have Biocompatible Internal Surfaces Causing Low Hemolysis Ninterested Bidder Is Required To Make A Demonstration N 39 Helium Gas For Refill Cylinder ( Iabp ) : Of 900 Ml Each N N1. Refilling Gas Is To Be Done For Cylinders Fitting With Existing Maquet Iabp Machine. N2. Cylinders To Be Filled With Compressed Helium . N3. Minimum Recommended Helium Grated For Filling Should Be U.S.P. 99.0% ( Un1046 ) N4. When Filled Content Should Be 90-9 Standard Liters@ 2200-2500 Psig ( 200 Barr ) At 70 Degree F N5. Volume Should Be 680-700 Cc N6. The Firm Should Ensure That Refilling Of An Empty Cylinder Is Completed ( And Cylinder Supplied Back To User Department ) Within 4-5 Days. N 40 Biological Indicator For Steam Autoclave N N1. Should Inadequate Biological Adequacy Of Steam Autoclave Nsterilization Process ( By Negative Or Positive Culture ) , Sterilization Nprocedure Will Be Done In Ot Autoclave At 120-132 * Celsius. N2. The Indicator Should Be In A Glass Cartridge / Test Strip Form. N N3. The Indicator Should Have Adequate Concentration Of Biological Indicator Nspores ( Geobacillus Stearothermophilus And / Or Bacillus Atropheaus ) . N4. The Indicator Cartridge / Strip, After Sterilization Process, Should Be Easily Transferable To The Microbiology Laboratory And Transfer To Culture Medium From The Strip / Cartridge Should Be Possible, In An Aseptic Manner. N5. The Container Box And Each Individual Strip / Cartridge Should Have A Label Nwith Expiry Date On It.

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail