| 1 | 1 | AIR CONDITIONER WINDOW/SPLIT TYPE 1.5/2.0/3.0 TR | | | |
|---|
| 2 | 2 | Dismantling and taking out the existing old unserviceable compressor sealed unit of any make from window/split type AC and S&F New compressor and charging refrigerent gas suitable for room type window AC/Split AC of capacity 1.0/1.5 Ton complete all as specified and directed. Make-Kirloskar/Tecumseh/Compland. Note:- Petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the department | | 19 | Each Job |
|---|
| 3 | 3 | All as per Srl item No.2 above but compressor suitable for room type window AC /Split AC of capacity 2.0 Ton complete all as specified and directed. Make-Kirloskar/Tecumseh/Compland | | 15 | Each Job |
|---|
| 4 | 4 | All as per Srl item No.2 above but compressor suitable for room type window AC /Split AC of capacity 3.0 Ton ccomplete all as specified and directed . Make-Kirloskar/Tecumseh/Compland | | 3 | Each Job |
|---|
| 5 | 5 | M&L for testing leakage in system Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed. Note:- Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department | | 25 | Each Job |
|---|
| 6 | 6 | All as per Srl item No 5 here-in-before but Air conditioner of 2 ton capacity | | 20 | Each Job |
|---|
| 7 | 7 | All as per Srl item No 5 here-in-before but Air conditioner of 3 ton capacity | | 3 | Each Job |
|---|
| 8 | 8 | M&L for servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed Note:-Spare parts shall be measured and paid separately | | 105 | Each Job |
|---|
| 9 | 9 | Supply only following items:- | | | |
|---|
| 10 | 9.01 | Starting capacitor of capacity 80/100 MFD | | 20 | Each |
|---|
| 11 | 9.02 | Starting capacitor of capacity 100/120 MFD | | 20 | Each |
|---|
| 12 | 9.03 | Starting capacitor of capacity 120/140 MFD | | 18 | Each |
|---|
| 13 | 9.04 | Starting capacitor of capacity 160/180 MFD | | 15 | Each |
|---|
| 14 | 9.05 | Condenser capacity of 5/6 MFD | | 20 | Each |
|---|
| 15 | 9.06 | Condenser capacity of 10 MFD | | 21 | Each |
|---|
| 16 | 9.07 | Condenser capacity of 25 MFD | | 15 | Each |
|---|
| 17 | 9.08 | Condenser capacity of 36 MFD | | 15 | Each |
|---|
| 18 | 9.09 | Condenser capacity of 45 MFD | | 16 | Each |
|---|
| 19 | 9.1 | Condenser capacity of 50 MFD | | 15 | Each |
|---|
| 20 | 9.11 | Condenser capacity of 55 MFD | | 15 | Each |
|---|
| 21 | 9.12 | Condenser capacity of 60MFD | | 10 | Each |
|---|
| 22 | 9.13 | Cooling Coil suitable for 1.0/1.5/2.0/3.0 Ton Capacity Air Conditioner | | 4 | Each |
|---|
| 23 | 9.14 | Swing motor suitable for 1.0/1.5/2.0/3.0 Ton Capacity Air Conditioner | | 4 | Each |
|---|
| 24 | 9.15 | Over load relay suitable for 1.0/1.5/2.0/3.0 Ton Window & Split AC | | 25 | Each |
|---|
| 25 | 9.16 | PVC Front gril suitable for Window AC of any Make suitable for 1.0/1.5/2.0/3.0 Ton Window AC | | 15 | Each |
|---|
| 26 | 9.17 | Electric blower motor suitable for 1.0/1.5 Ton Capacity Window type AC | | 12 | Each |
|---|
| 27 | 9.18 | Electric blower motor but suitable for 2.0 Ton Capacity Window type AC | | 5 | Each |
|---|
| 28 | 9.19 | Electric blower motor but suitable for 3.0 Ton Capacity Window type AC | | 2 | Each |
|---|
| 29 | 9.2 | Electric blower motor but suitable for 1/1.5 Ton Split AC (Evaporator/Condenser) | | 20 | Each |
|---|
| 30 | 9.21 | Electric blower motor but suitable for 2.0 Ton Split AC (Evaporator/Condenser) | | 12 | Each |
|---|
| 31 | 9.22 | Electric blower motor but suitable for 3.0 Ton Split AC (Evaporator/Condenser) | | 2 | Each |
|---|
| 32 | 9.23 | Blower motor fan blade suitable for 1.0/1.5/2.0/3.0 Suitable for Window /Split type AC | | 15 | Each |
|---|
| 33 | 9.24 | Condenser motor with fan blade suitable for 1.0/1.5/2.0/3.0 Suitable for Split type AC | | 20 | Each |
|---|
| 34 | 9.25 | Thermostat switch with knob suitable for AC of any capacity. | | 30 | Each |
|---|
| 35 | 9.26 | Air Filter Suitable for 1.0/1.5/2.0/3.0 Ton Capacity Air conditioner | | 25 | Each |
|---|
| 36 | 9.27 | Capillary tube length as per existing size suitable for 1.0/1.5/2.0/3.0 Ton Capacity Air conditioner | | 20 | Each |
|---|
| 37 | 9.28 | PCB Circuit with remote control suitable for any make and any capacity Make: Renutrol/Indfos/Kelvinator or equivalent | | 30 | Each |
|---|
| 38 | 9.29 | Metal top with bottom suitable for 16 Amps Capacity 1.0/1.5/2.0/3.0 Ton Capacity Air conditioner | | 50 | Each |
|---|
| 39 | 9.3 | Oxyzen Gas | | 5 | Kg |
|---|
| 40 | 9.31 | Brazing rod | | 15 | Each |
|---|
| 41 | 9.32 | Carbite stone | | 10 | Kg |
|---|
| 42 | 10 | M&L repair & replacement of new Suction pipe suitable for 1.0/1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed | | 15 | Each |
|---|
| 43 | 11 | M&L for replacement of damaged Insulation of size 1/4, 3/8 for Split AC complete as per existing site complete all as specified and directed | | 100 | Rm |
|---|
| 44 | 12 | M&L for replacement of damaged Insulation of size 1/2 5/8 for Split AC complete as per existing site complete all as specified and directed | | 100 | Rm |
|---|
| 45 | 13 | M&L for replacement of Rubber bush suitable for 1.0/1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed | | 10 | Each set |
|---|
| 46 | 14 | M&L for replacement of Copper Tube of size 1/4 3/8 suitable for any type and any capacity Air conditioner complete all as specified and directed | | 20 | Rm |
|---|
| 47 | 15 | M&L for replacement of Copper Tube of size 1/2 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed | | 25 | Rm |
|---|
| 48 | 16 | M&L for replacement of Plug nut of size 1/4 3/8 suitable for any type and any capacity Air conditioner complete all as specified and directed | | 10 | Each |
|---|
| 49 | 17 | M&L for replacement of Plug nut of size 1/2 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed | | 10 | Each |
|---|
| 50 | 18 | Taking out and shifting new location and refixing both indoor and outdoor unit of split type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0/3.0 Ton in wall with rowl plugs including making holes for inlet /outlet in the wall with 50mmX50mmX6mm size of agle iron for foundation of condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed. Note:- Refilling of refrigerant and additional copper pipe required shall be measured and paid separately under respective item. | | 25 | Each Job |
|---|
| 51 | 19 | M&L for repairs to walk in cooler 1.5 Ton and repair/replacement the compressor, filter including gas charging and general service complete all as specified and directed. | | 1 | Each Job |
|---|
| 52 | 20 | M&L for Charging of gas R-22 as exhisting Air Conditioner (Split & Window AC) any capacity complete all as specified and directed | | 100 | Kg |
|---|
| 53 | 21 | M&L for Charging of gas R-4 as exhisting Air Conditioner (Split & Window AC) any capacity complete all as specified and directed | | 50 | Kg |
|---|
| 54 | 22 | WATER COOLER | | | |
|---|
| 55 | 23 | Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F new compressor copper wound unit, suitable for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I, Make-Shriram/ Tecumseh/ Kirlosker or equalvent inc refrigerent gas all allied works as cutting, brazing, wiring etc suitable for Water cooler of cooling capacity 40/80 ltrs/hrs and complete testing, commissioning to the entire satisfaction of Engineer-in-charge complete all as specified and directed. Note:- Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department | | 6 | Each Job |
|---|
| 56 | 24 | All as per Srl item No.23 here in before but compressor suitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed.. | | 5 | Each Job |
|---|
| 57 | 25 | All as per Srl item No.23 here in before but compressor suitable for Water Cooler of cooling capacity 60/80 ltrs/hrs complete all as specified and directed.. | | 8 | Each Job |
|---|
| 58 | 26 | All as per Srl item No.23 here in before but compressor suitable for Water Cooler of cooling capacity 80/100 ltrs/hrs complete all as specified and directed.. | | 8 | Each Job |
|---|
| 59 | 27 | All as per Srl item No.23 here in before but compressor suitable for Water Cooler of cooling capacity 100/120 ltrs/hrs complete all as specified and directed.. | | 8 | Each Job |
|---|
| 60 | 28 | All as per Srl item No.23 here in before but compressor suitable for Water Cooler of cooling capacity 80/150 ltrs/hrs complete all as specified and directed. | | 3 | Each Job |
|---|
| 61 | 29 | M&L for checking the unserviceable water cooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- Spare parts shall be measured and paid separately | | 50 | Each Job |
|---|
| 62 | 30 | Supply only following items:- | | | |
|---|
| 63 | 30.01 | Condensor motor SP,230V, 50 Hz suitable for 40/80 Ltr capacity water cooler as per existng sample complete all as specified and directed | | 10 | Each |
|---|
| 64 | 30.02 | All as per item here in before but suitable for 150/180 Ltr, 60/120 Ltr or equivalent water cooler as per existng sample complete all as specified and directed | | 10 | Each |
|---|
| 65 | 30.03 | Condenser fan blade suitable for 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity water cooler | | 7 | Each |
|---|
| 66 | 30.04 | Capacitor for condenser motor suitable for any capacity, size complete | | 10 | Each |
|---|
| 67 | 30.05 | Starting Capacitor suitable for compressor of water cooler 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity | | 25 | Each |
|---|
| 68 | 30.06 | Running Capacitor suitable for compressor of water cooler 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity | | 30 | Each |
|---|
| 69 | 30.07 | Starting relay current type suitable for compressor of water cooler 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity | | 15 | Each |
|---|
| 70 | 30.08 | Over load Protector suitable for compressor of water cooler 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity | | 20 | Each |
|---|
| 71 | 30.09 | Thermostat switch with knob suitable for compressor of water cooler 150/180 Ltr ,60/120 Ltr and 40/80 Ltr capacity | | 25 | Each |
|---|
| 72 | 30.1 | Brass Valve asssembly with PVC float with complete accessories for water cooler any capacity of size 15 mm dia | | 25 | Each |
|---|
| 73 | 30.11 | Self closing water tap chromium plated inner/outer thread for water cooler 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity | | 30 | Each |
|---|
| 74 | 30.12 | Air Filter Suitable for water cooler 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity | | 20 | Each |
|---|
| 75 | 30.13 | Capillary tube of suitable length as per existing size for water cooler 150/180 Ltr, 60/120 Ltr and 40/80 Ltr capacity | | 25 | Each |
|---|
| 76 | 31 | M&L for Charging of gas R-22 as exhisting water cooler any capacity complete all as specified and directed | | 50 | Kg |
|---|
| 77 | 32 | M&L for Charging of gas HFC-134a as exhisting water cooler any capacity complete all as specified and directed | | 20 | Kg |
|---|
| 78 | 33 | M&L for MS work fabrication base of water cooler using angle iron/ fluto iron (any size), nut bolts, incl cutting welding, drilling etc and one primer coat of red oxide complete all as specified and directed | | 40 | Each Job |
|---|
| 79 | 34 | M&L for testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system complete | | 5 | Each Job |
|---|
| 80 | 35 | M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket complete all as specified and directed | | 5 | Each Job |
|---|
| 81 | 36 | M&L for replacement of water cooler inner tank made of stainless steel as per existing capacity & size with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and directed | | 5 | Each Job |
|---|
| 82 | 37 | REFRIGERATOR | | | |
|---|
| 83 | 38 | M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make-Tecumesh, Godrej, Voltas or whirlpool , LG or equivalent including necessary gas welding, making the system leak proof, including Repair to leakage in system by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and testing, the system for smooth functioning complete and charging of exhisting refrigerent gas complete all as specified and directed Note:- Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department | | 19 | Each Job |
|---|
| 84 | 39 | All as per Srl item No.38 here in before but compressor suitable for refrigerator capacity of 286 to 320 Ltrs complete all as specified and directed.. | | 13 | Each Job |
|---|
| 85 | 40 | M&L Checking the unserviceable Refirgerator of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- Spare parts shall be measured and paid separately | | 60 | Each job |
|---|
| 86 | 41 | Supply only following items:- | | | |
|---|
| 87 | 41.01 | Magnetic door gasket suitable for 165 to 200 ltrs capacity Refrigerator | | 15 | Each |
|---|
| 88 | 41.02 | All as per item S.No. 28.01 here in before but suitable for 286/320 Ltrs capacity Refigerator | | 10 | Each |
|---|
| 89 | 41.03 | Freezer suitable for 165 to 200 ltrs capacity Refrigerator | | 10 | Each |
|---|
| 90 | 41.04 | All as per item s.No. 38.03 here in before but suitable for 286/310 Ltrs capacity Refigerator | | 15 | Each |
|---|
| 91 | 41.05 | Relay current type and over load protector suitable for compressor complete Make: Ranutrol/Voltas/LG | | 15 | Each |
|---|
| 92 | 41.06 | Thermostat auto defrost type suitable for any make and any capacity Refrigerator Make: Danfos/Ind Foss/renutrol or Equivalent | | 14 | Each |
|---|
| 93 | 41.07 | Air Filter suitable for for any make and any capacity Refrigerator | | 15 | Each |
|---|
| 94 | 41.08 | Capillary tube of suitable length as per existing size for refrigerator any make and any capacity | | 20 | Each |
|---|
| 95 | 41.09 | Vegitable tray as per sample and suitable for refrigertator any type and any make | | 14 | Each |
|---|
| 96 | 41.1 | PVC Stand for Refigerator capacity any make and any capacity | | 25 | Each |
|---|
| 97 | 42 | M&L for charging of Refrigerant gas HFC-134a in refrigerator of any capacity complete all as specified and directed | | 50 | Kg |
|---|
| 98 | 43 | DEEP FREEZER | | | |
|---|
| 99 | 44 | M&L for removing burnt/defective sealed compressor unit of any make from Capacity 155 to 200 Ltr of Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make-Tecumesh, Godrej, Voltas or whirlpool , LG, including necessary gas welding, making the system leak proof, including Repair to leakage in system by charging of nitrogen gas upto 300 PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and testing, the system for smooth functioning complete and charging of exhisting refrigerent gas complete all as specified and directed. Note:- Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department | | 2 | Each Job |
|---|
| 100 | 45 | All as per Srl item No.44 here in before but compressor suitable for Deep freezer capacity of 250 to 320 Ltrs complete all as specified and directed.. | | 7 | Each Job |
|---|
| 101 | 46 | M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete all as specified and directed. | | 6 | Each Job |
|---|
| 102 | 47 | M&L for checking the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. Note:-Spare parts shall be measured and paid separately | | 20 | Each Job |
|---|
| 103 | 48 | Supply only following items:- | | | |
|---|
| 104 | 48.01 | Relay current type and over load protector suitable for compressor | | 15 | Each |
|---|
| 105 | 48.02 | Thermostat auto defrost type suitable for any make and any capacity Deep Freezer Make: Danfos/Ind Foss/renutrol or equivalent | | 15 | Each |
|---|
| 106 | 48.03 | Drier filter complete set suitable for any make and any capacity Deep Freezer | | 14 | Each |
|---|
| 107 | 48.04 | Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complte | | 10 | Each |
|---|
| 108 | 48.05 | Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity | | 18 | Each |
|---|
| 109 | 48.06 | Starting relay suitable for 310/320 ltrs capacity Deep freezer | | 15 | Each |
|---|
| 110 | 48.07 | Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer Make; AUE/Cool Blow/Universal or equivalent | | 10 | Each |
|---|
| 111 | 48.08 | Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer | | 10 | Each |
|---|
| 112 | 49 | M&L for charging of Refrigerant gas HFC-134a in refrigerator of any capacity complete all as specified and directed | | 50 | Kg |
|---|
| 113 | 50 | DESERT COOLER | | | |
|---|
| 114 | 51 | Dismantling and taking out the existing old unsv fan motor with blade from Desert coolers and S&F new fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable for D/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed Make- Khaitan/Cool Blow/Dynamic or equivalent Note:- Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department | | 10 | Each Job |
|---|
| 115 | 52 | M&L for repair to Desert cooler dismantling the unserviceable parts of desert coolers,checking the general servicing complete all as specified and directed. Note:- Spare parts shall be measured and paid separately | | 70 | Each Job |
|---|
| 116 | 53 | Supply only following items:- | | | |
|---|
| 117 | 53.01 | Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr Make: TESLA/TEXMO or equivalent | | 50 | Each |
|---|
| 118 | 53.02 | Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size | | 25 | Set of 3 |
|---|
| 119 | 53.03 | Capacitor 2.5/4MFD Make: Usha/Asian/KEIL V | | 50 | Each |
|---|
| 120 | 53.04 | Capacitor 5/6 MFD Make: Usha/Asian/KEIL V | | 45 | Each |
|---|
| 121 | 53.05 | Front panel of dimension as per existing size suitable for desert cooler of capacity 4000/5000/6000 Cum per hrs | | 10 | Each |
|---|
| 122 | 53.06 | Panels suitable for as per existing size for desert cooler of capacity 4000/5000/6000 Cum per hrs | | 10 | Set of 3 |
|---|
| 123 | 53.07 | PVC Flexible hose suitable for desert cooler cooling system | | 30 | Rm |
|---|
| 124 | 53.08 | PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample | | 20 | Each |
|---|
| 125 | 53.09 | Selector switch as per existing model and size | | 25 | Each |
|---|
| 126 | 53.1 | Bolt, nut with washers as per sample | | 2 | Kg |
|---|
| 127 | 53.11 | PVC Connector i.e (Elbow, Tee,4 way etc) | | 50 | Each |
|---|
| 128 | 54 | VOLTAGE STABILZER | | | |
|---|
| 129 | 55 | M&L for repair to Voltage stablizer of capacity 0.5/1.0/2.0KVA, dismantling the unserviceable parts of voltage stablizer ,checking the general servicing complete all as specified and directed. Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (ii) Spare parts shall be measured and paid separately | | 40 | Each Job |
|---|
| 130 | 56 | All as per Srl item No.55 here in before but voltage Stablizer of capacity 3/4/5 KVA complete all as specified and directed. | | 40 | Each Job |
|---|
| 131 | 57 | Supply only following items:- | | | |
|---|
| 132 | 57.01 | Relay for the existing capacity of stabilizer any make and any capacity | | 10 | Each |
|---|
| 133 | 57.02 | Trigger transformer for the existing capacity of stabilizer any make and any capacity | | 10 | Each |
|---|
| 134 | 57.03 | Circuite plate for the existing capacity of stabilizer any make and any capacity | | 10 | Each |
|---|
| 135 | 57.04 | Cut out of 15 Amps for the existing capacity of stabilizer any make and any capacity | | 10 | Each |
|---|
| 136 | 57.05 | Volt meter indicating 100-300 Volt for the existing capacity of stabilizer any make and any capacity | | 10 | Each |
|---|
| 137 | 57.06 | PVC insulated and PVC over all covered cord cable copper conductor 3 core of size 4 Sqmm Make- Plaza/Havells/ Finolex. | | 100 | RM |
|---|
| 138 | 57.07 | Sheet metal enclosures with flush mounted type ply and socket with 240 V SP MCB 20 amps Capacity Make: ABB/Legrand/Havells or Equivalent | | 20 | Each |
|---|
| 139 | 58 | S&F Voltage Stabilizer of capacity 3.0 KVA with connected wiring with accessories including taking out the unserviceable defective Voltage Stabilizer complete all as specified and directed. Make:- V GUARD/VOLTAS | | 5 | Each |
|---|
| 140 | 59 | All as per Srl item No. 58 but 4/5 KVA Capacity -ditto- | | 2 | Each |
|---|
| 141 | 60 | Dismantling the Transformer from voltage stablizer of capacity 0.5/1.0KVA and S&F new transformer with supper enamelde copper wire of approved quality of existing guage and testing complete all as specified and directed | | 2 | Each Job |
|---|
| 142 | 61 | Dismantling the Transformer from voltage stablizer of capacity 3/4/5 KVA andS&F new transformer with supper enamelde copper wire of approved quality of existing guage and testing complete all as specified and directed | | 5 | Each Job |
|---|
| 143 | 62 | M&L for writing Nos or figures (Block, Roman, Italic or Indian) such as \"MES No, Name of Division ….\" with synthetic enamel paint (1st grade quality) of tint black/white complete all as required and directed. (Per 25 Nos letter/figure & no. of 2 cm height) in each plant such as water cooler, refrigerator, Deep freezer complete all as specified and directed | | 50 | Each Job |
|---|
| 144 | 63 | M&L for sub main wiring with 6 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point including taking down exisiting sub main wiring of any type complete as specified and directed. Note :- PVC conduits/casing caping and Two runs cables and one run of earth wire shall be measured as one length. | | 90 | Rm |
|---|
| 145 | 64 | M&L for sub main wiring with 4 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point including taking down exisiting sub main wiring of any type complete as specified and directed. Note :- PVC conduits/casing caping and Two runs cables and one run of earth wire shall be measured as one length. | | 60 | Rm |
|---|
| 146 | 65 | Taking down carefully unserviceable copper/aluminium point wiring including unserviceable fittings such as switches, ceiling roses, regulators etc complete and making good disturbed surfaces of walls, floors etc.complete all as specified and as directed | | 12 | Point |
|---|
| 147 | 66 | M&L for point wiring with 2.5 Sqmm (nominal area), power point controlled by one ,one way switche PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete all as specified and as directed | | 12 | Point |
|---|