| 1 | 1 | Taking out unserviceable HT UG CABLE of any size and any type up to 240 Sq mm 3 core including necessary earth work all as directed by Engr -in-charge. | | 180 | RM |
|---|
| 2 | 2 | Taking out unserviceable LT UG CABLE of any size and any type up to 300 Sq mm 3.5 core including necessary earth work all as directed by Engr -in-charge. | | 850 | RM |
|---|
| 3 | 3 | Relaying only serviceable HT UG CABLE of 185 Sq mm 3 core received from item no 01 of above including jointing and testing material all as directed by Engr -in-charge. (NOTE:-Earth work ,sand coushiong and protection bricks meaured and paid separtely.) | | 40 | RM |
|---|
| 4 | 4 | Relaying only serviceable HT UG CABLE of 240 Sq mm 3 core received from item no 01 of above including jointing and testing material all as directed by Engr -in-charge. (NOTE:-Earth work ,sand coushiong and protection bricks meaured and paid separtely.) | | 10 | RM |
|---|
| 5 | 5 | Relaying only serviceable LT UG CABLE of 185 Sq mm 3.5 core received from item no 02 of above including jointing and testing material all as directed by Engr -in-charge. (NOTE :- Earth work ,sand coushiong and protection bricks meaured and paid separtely.) | | 60 | RM |
|---|
| 6 | 6 | Relaying only serviceable LT UG CABLE of 300 Sq mm 3.5 core received from item no 02 of above including jointing and testing material all as directed by Engr -in-charge. (NOTE :- Earth work ,sand coushiong and protection bricks meaured and paid separtely.) | | 540 | RM |
|---|
| 7 | 7 | Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sq mm 3 core size . Make : Havells/Gloster/KEI/ Polycab/Fonolex | | 450 | RM |
|---|
| 8 | 8 | Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 240 sq mm 3 core size ISI marked. Make : Havells/Gloster/KEI/ Polycab /Fonolex | | 50 | RM |
|---|
| 9 | 9 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm. Make: Birla 3M/ Raychem/ Denson. | | 1 | Each |
|---|
| 10 | 10 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson. | | 4 | Each |
|---|
| 11 | 11 | Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm. Make: Birla 3M/ Raychem/ Denson | | 1 | Each |
|---|
| 12 | 12 | Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson | | 3 | Each |
|---|
| 13 | 13 | Supply and fix cable jointing kit for 11 KV grade cable for straight through outdoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm. Make: Birla 3M/ Raychem/ Denson | | 1 | Each |
|---|
| 14 | 14 | Supply and fix cable jointing kit for 11 KV grade cable for straight through outdoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson | | 6 | Each |
|---|
| 15 | 15 | Supply and laying or fixing or passing through pipe or in cable trench or ducts, 1100 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 300 sq mm 3.5 core size ISI marked. Make : Havells/Gloster/KEI/ Polycab /Fonolex | | 900 | RM |
|---|
| 16 | 16 | Supply and laying or fixing or passing through pipe or in cable trench or ducts, 1100 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sq mm 3.5 core size ISI marked. Make : Havells/Gloster/KEI/ Polycab /Fonolex | | 250 | RM |
|---|
| 17 | 17 | M& L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conducter cable of size 3.5 core 300 sq mm complete all as specified and directed. Make: Birla 3M/ Raychem/ Denson | | 26 | Each |
|---|
| 18 | 18 | M& L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conducter cable of size 3.5 core 185 sq mm complete all as specified and directed. Make: Birla 3M/ Raychem/ Denson. | | 4 | Each |
|---|
| 19 | 19 | Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying cables/ pipe line etc. and getting out in soft/loose soil | | 200 | Cum |
|---|
| 20 | 20 | Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point. | | 110 | Cum |
|---|
| 21 | 21 | Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil. | | 90 | Cum |
|---|
| 22 | 22 | Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured) | | 50 | Cum |
|---|
| 23 | 23 | Supply and laying sub class 'B' bricks of old size (23x11x7cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge | | 1000 | Each |
|---|
| 24 | 24 | S&F MS angles, bars flats etc, as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to Fe 410-0 or Fe 310-0 complete. | | 100 | Kg |
|---|
| 25 | 25 | Preparation of new or previously untreated steel surfaces of any descrption, over 10 CM width or grith, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromer primer complete. | | 20 | Sqm |
|---|
| 26 | 26 | Supply and laying un-reinforced pre cast cover of size (300mmx180mmx40mm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge | | 800 | Each |
|---|
| 27 | 27 | Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 150 MM size light grade for protection of cable complete all as directed.\nMake: TATA / Jindal / Surya | | 20 | RM |
|---|
| 28 | 28 | M &L Plain cement concrete 1:4:8 type C2 (using 40 mm aggregrate) as in foundations filling mass concrete cable ducts / covers etc complete all as specified and directed | | 50 | Cum |
|---|
| 29 | 29 | M &L for cement concrete PCC 1:2:4 type B1 (using 20 mm aggregrate) as coping of poles complete all as specified and directed | | 25 | Cum |
|---|
| 30 | 30 | Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 100 MM size light grade for protection of cable complete all as directed.\nMake: TATA / Jindal / Surya | | 15 | RM |
|---|
| 31 | 31 | M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including GI pipe, 150 mm bore, light grade for drawing cable complete all specified and as directed | | 50 | RM |
|---|
| 32 | 32 | Cutting trench through road/ wall/putpath to a width of 20cm and depth of 30cm for inserting GI protection pipe for drawing cable and filling back the trench with the same items of PCC 1:3:6 type C1 i.e bituminois/foot path etc complete all as directed. | | 50 | RM |
|---|