}

Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc, RCC-TVM-Kerala

Regional Cancer Center has published Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc. Submission Date for this Tender is 28-10-2019. Forming Tools Tenders in RCC-TVM Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

22190525
Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc
Open Tender
Indian
Kerala
Rcc-Tvm
28-10-2019

Tender Details

Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc Urgent Rectification Works And Provision Of Firefighting Equipments At A , B , C And D Block Of Rcc , Fire Detection & Alarm System , Supply , Installation , Testing & Commissioning Of The Fire Alarm System Consisting Of The Following , Microprocessor Based Conventional Fire Alarm Control Panel , Can Accommodate Maximum Range Of 32 Zones , S . User Friendly Systems Which Involves A Touch Keypad To Program The Panel Operates On 120 - 220Vac 60 /50 Hz , Ac Mains Power Supply Standby ( Battery ) Backup 24 Vdc Power Supply With Built In Charger Zone Isolation Facility With Loop Voltage Cut Off . Resettable / Steady 24Vdc . Output . , Microprocessor Based Conventional Fire Alarm Control Panel , Can Accommodate Maximum Range Of 24 Zones , S . User Friendly Systems Which Involves A Touch Keypad To Program The Panel Operates On 120 - 220Vac 60 /50 Hz , Ac Mains Power Supply Standby ( Battery ) Backup 24 Vdc Power Supply With Built In Charger Zone Isolation Facility With Loop Voltage Cut Off . Resettable / Steady 24Vdc . Output . , Microprocessor Based Conventional Fire Alarm Control Panel , Can Accommodate Maximum Range Of 16 Zones , S . User Friendly Systems Which Involves A Touch Keypad To Program The Panel Operates On 120 - 220Vac 60 /50 Hz , Ac Mains Power Supply Standby ( Battery ) Backup 24 Vdc Power Supply With Built In Charger Zone Isolation Facility With Loop Voltage Cut Off . Resettable / Steady 24Vdc . Output . , Microprocessor Based Conventional Fire Alarm Control Panel , Can Accommodate Maximum Range Of 6 Zones , S . User Friendly Systems Which Involves A Touch Keypad To Program The Panel Operates On 120 - 220Vac 60 /50 Hz , Ac Mains Power Supply Standby ( Battery ) Backup 24 Vdc Power Supply With Built In Charger Zone Isolation Facility With Loop Voltage Cut Off . Resettable / Steady 24Vdc . Output . , Supply , Installation , Testing & Commissioning Of The Cable , Sitc Of Fire Alrm Cable- Pvc Insulated Fire Retardent Copper Flexible Cable A Sq . Mm With Isi Mark , Pvc Conduit . , Sitc Of 20Mm Dia Medium Grade Rigid Pvc Conduit With Isi Mark With Elbows , Tees , Junction Boxes , Saddle Clips With Necessary Fittings . , Smoke/Heat Detector , Sitc Of Optical Smoke/Heat Detector With Operating Voltage Range 12-24Vdc Min . , Application Temperature 30 - 70 Degree With Imported Base , Manual Call Point , Sitc Of Manual Call Point Break Glass Type Powder Coated Ms Box , 21/12 Vdc Operated , And With Necessary Attachment Like Hammer , Fire Hydrant System , Fire Brigade Connection , Sitc Of Fire Brigade Inlet Connection Fabricated From 100 Mm Dia . Ms Class B Medium Grade Pipe Three 63 Mm Dia . Gun Metal Male Threaded Non Return Valve . , Servicing And Testing Of Pumps , Hose Box , Valves Etc . , Servicing , Testing And Commissioning Of Existing Electrically Operated Fire Pump Of 75 Kw , Servicing , Testing And Commissioning Of Existing Electrically Operated Jockey Pump Of 5 . 5 Kw , Servicing , Testing And Commissioning Of Existing Electrically Operated Sprinkler Pump Of 44 . 5 Kw , Servicing , Testing And Commissioning Of Following Butter Fly Valves , 150/100/80 Mm Dia , Servicing , Testing And Commissioning Of Following Non Return Valves , 150/100/80 Mm Dia , Testin And Servicing Of Control Panel - Pump , Servicing , Testing And Commissioning Of Pressure Switch Having 1/4 Bsp ( F ) Connection Ip : 32 , Servicing , Testing And Commissioning Of Pressure Gauges 4 Dial , 0-200 Psi Range 3/8 Bsp Weather Proof Type . , Servicing , Testing And Commissioning Of Air Release Valve With Gun Metal Body , Servicing , Testing And Commissioning Of Air Cushion Vessel , Servicing , Testing And Commissioning Of Cast Iron Foot Valves Of Following Sizes , 200/150/100 Mm Dia . , Servicing , Testing And Commissioning Of Hydrant Valves Of 63Mm Dia . , Servicing , Testing And Commissioning Of Fire Fighting Hose , Servicing , Testing And Commissioning Of Hose Reel And Hose Reel Drum , Servicing , Testing And Commissioning Of Hose Box , Servicing , Testing And Commissioning Of Branch Pipe , Fire Extinguishers , Sitc Of Providing And Fixing Of Stored Pressure Abc Type Fire Extinguishers Of Capacity 6Kg As Per As Per Is 15683 : 2006 And Ce Certificate Consisting Of Welded Ms Cylindrical Body Of , With Control Valve , Syphon Tube , Discharge Nozzle , Hose , Neck Ring With Fire Rating 3A 21 B , Working Temperature -10 To 550C , Testing Pressure 35 Bar , Discharge Range 2 Meter , 90% Discharge Percentage With Helium Leak Detection Tested To 10-7 Mbar L/S And Hanging Arrangement In Appropriate Locations Of The Building Complete , Sitc Of Portable Watermist Based Extinguishers Of 6 Liters Capacity Which Fights Fires Of Class A , Class E And Class F Rating With Discharge Time Of Min . 9 Sec . And A Range Of Min . 2 Meters Welded Cylindrical Ms/Ss Body And A Hanging Arrangement In Appropriate Location As Per The Instruction Of Engineer In Charge , Test Certificate/Noc , Laison Work For Effective Approval In Writing , Contractor Shall Prepare And Submit Drawing And Other Necessary Documents , Attend All Tests And Inspections Carried Out By Local Fire Authorities , And Shall Forthwith Execute Free Of Charge If Any Rectifications Work Ordered By The Engineer- In- Charge As A Result Of Such Tests And Inspections Where These Indicate Non-Compliance With Statutory Regulations . All The Expenses Incurred In This Regard Shall Be Borne By The Contractor . The Official Payments To Be Made For Any Security Deposit Etc . In This Regard Which Shall Be Reimbursed On Production Of Original Vouncher .

Key Value

Document Fees
INR 5900 /-
EMD
INR 48000.0 /-
Tender Value
INR 19.11 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail