}

Repair To Rcc Structures In Cpcl Manali, CPCL, Manali-Tamil Nadu

Chennai Petroleum Corporation Limited has published Repair To Rcc Structures In Cpcl Manali. Submission Date for this Tender is 18-10-2019. Cutting Crimping and Punching Tools Tenders in CPCL, Manali Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

22045507
Repair To Rcc Structures In Cpcl Manali
Open Tender
Indian
Tamil Nadu
Cpcl, Manali
18-10-2019

Tender Details

Repair To Rcc Structures In Cpcl Manali , Repair To Rcc Structures In Cpcl Manali , Providing And Fixing Double Scaffolding System On The Exterior Side , Up To Sevenstory Height Made With 40Mm Diam . S . Tube 1 . 5M Centre Horizontal &Vertical Tubes Joining With Cup & Locksystem With M . S . Tubes , M . S . Tubechallies , M . S . Clamps And M . S . Stair Casesystem In The Scaffolding For Workingplatform Etc . , And Maintaining It In Aserviceable Condition For Therequiredduration As Approved And Removing Ithere After . The Scaffolding System Shallbe Stiffened With Bracings , Runners , Connection With The Building Etc . Wherever Required Forinspection Of Workat Required Locations With Essentialsafety Features For The Workman Etc . Complete As Per Directions And Approvalof Engineer-In-Charge . The Payment Wll Be Made Once Irrespective Of Duration , Chipping Of Unsound / Weak Concrete Material From Slabs , Beams , Columnsetc . , With Standard Power Drivenpercussion Type Of Pneumatic Chisel Ofstandard Make As Directed By Engineerin Charge . Includig Tapering All Edgesmaking Square Shoulders Of Cavitiesremoving Concrete All Roundreinforcement Including From Behind Thereinforcing Bars To Give An Average25mm ( But Not Less Than 15Mm Clear Air Gap ) Upto 100 Mm Thick , Spray Mortar:Providing And Applying On The Exposedsurfaces Of Roof Slabs / Vertical Wallswith Single Component , Micro Silicaenhanced , High Strength Shotcretemortar Like Fosrocrenderoc Ds40 Or Equivalent Material Using Suitablepumping Devices And As Permanufacturers Specifications . Therepair Spray Mortar Shall Have Aminimum Compressivestrengthof 15Mpa After 24 Hours And 40 Mpa At 28Days , And Does Not Require Any Coat Ofpolymer Bonding Agent As A Primer . Item Rate Is Inclusive Of Materials , Alllabour , Supervision , Tools And Tacklesand Transportation Etc . Complete As Per Specifications And As Directed . ( Average 40Mm Thick ) , Providing And Fixing Special Water Tight Centering Including Bolting , Strutting , Propping , Etc . , So As To With Stand A Pressure Of 0 . 1Mpa Including Removal Of Forms For All Location Including Beams Columns Slabs , Walls , Foundations , Footings , Landings , Stairs , Balconies Etc , Providing And Placing In Position Micro Concrete Of Grade M55 With Graded Coarse Aggregates Of Maximum Size 12Mm Of Ratio 1:0 . 75 ( Mc : Agg ) If Repair Section Greater Than 50 Mm Depth , Which Shall Be Cement Based Pre-Packed Single Component Of Make Fosroc / Sika / Basf , Chloride Free , Non-Shrink , Free Flow , Self Compacting Ready To Use After Mixing Water In Specified Proportion Obtained From Approved Manufacturer As Per Specification And Direction Of Engineer In Charge In Columns , Beams , Roofs Etc By Pouring / Pumping / Making Pockets For Pouring . Curing Has To Be Carried Out Using Polymer Based Continuous Film Forming Curing Compound . , Mixing And Applying Bonding Coat , Exluding Cost Of Material , On Prepared Non Metallic Surface Of Parent Materialas Per Specifications And Direction Of Engineer -In -Charge Complete . , Supply Of Approved Epoxy ( Total Weight Of Resin & Hardener In Proportion Specified By Manufacturer ) Bonding Material For Prepared Non Metallic Surface . , Injecting Approved Epoxy ( Total Weight Of Resin And Hardener In Proportion Speified By Manufacturer ) Grout Into Crack/Honey Comb Areas Of Concrete By Suitable Gun/Pump Of Required Pressure Including Cutting The Nipples After Curing Etc . Complete As Per Directions Of The Engineer-In -Charge ( Payment Shall Be Made On The Basis Of Actual Weight Of Approved Grout Injected ) , Supply Of Approved Epoxy ( Total Weight Of Resin & And Hardener In Proportionspecified By Manufacturer ) Crack /Honey Combed Area Sealing Material/Admixture . , Applying Alkaline Passivating & Anticorrosive Coat Of Approved Epoxy Zinc Anti Corrosive Primer For Reinforcements , Excluding The Cost Of Material But Including Supplying And Sprinkling Silica Sand ( No . 10 ) Over Steel Reinforcement Duly Approved By Engineer In Charge . For Steel Reinforcement Bars Upto & Including 12Mm Diameter , Applying Alkaline Passivating & Anticorrosive Coat Of Approved Epoxy Zinc Anti Corrosive Primer For Reinforcements , Excluding The Cost Of Material But Including Supplying And Sprinkling Silica Sand ( No . 10 ) Over Steel Reinforcement Duly Approved By Engineer In Charge . For Steel Reinforcement Bars Above 16Mm Diameter , Supply Of Alkaline Passivating & Anticorrosive Coat Of Approved Epoxy Zinc Anti Corrosive Primer For Reinforcements ( Payment Shall Be Qty Of Resin Plus Hardener In Manufacturer Specified Proportion ) For Steel Reinforcement . , Introducing New Reinforcement Bar For Structural Connections In Rcc Beams , Lintels , Columns And Slabs Includingpower Drilling Holes Of Appropriatediameters In Reinforced Or Plain Cementconcrete A Minimum Depth Of 150Mmand Upto 200Mm Fixing Thereinforcement In Position Drilling Inconcrete , Epoxy Cartridges , Plasticnozzle Etc . , Complete Including Cleaningthedrilled Holes Of Loose Dust Byblowing Air . The Cost Of Reinforcementshall Be Payable Separately . Upto And Including For 12Mm Dia Reinforcing Bar . , Introducing New Reinforcement Bar For Structural Connections In Rcc Beams , Lintels , Columns And Slabs Includingpower Drilling Holes Of Appropriatediameters In Reinforced Or Plain Cementconcrete A Minimum Depth Of 150Mmand Upto 200Mm Fixing Thereinforcement In Position Drilling Inconcrete , Epoxy Cartridges , Plasticnozzle Etc . , Complete Including Cleaningthedrilled Holes Of Loose Dust Byblowing Air . The Cost Of Reinforcementshall Be Payable Separately . Above For 12Mm Dia Reinforcing Bar . , Providing And Inserting Mild Steel Shearkey Bars Levelling Gauge ( For Shorcreting ) Of Required Length And Diameter Inreinforced / Plain Concrete As Per Drawing And Directions Of Engineer-In-Charge Including Power Drilling Holes Of Appropriate Dia To A Minimum Depth Of Equal To 12 Times The Diameter Of Shear Key Bar / Levelling Gauge , Cleaning The Drilled Holes Of Loose Duty By Blowing , Insertion Of Epoxy From Cartridge , Placing The Shear Key Bar In Position And Allowing It To Stay Undisturbed For 24 Hours 12Mm And 300Mm Long ( The Projected Length Of Shear Key Shall Be More Than 10 Times Its Diameter Plus Half The Thickness Of Cover Concrete Plus Bendlength ) M . S . Shear Key . , Supplying And Placing In Position Hard Drawn Steel Wire Fabric Of 3Mm Dia . 50X50mesh @ 2 . 22Kg/Sq . M As Per Is:1566 Post Weld Hot Dipped Galvanized With Zn Loading Of 250 Gm/M2 , To Be Used As Reinforcement , Including Straightening , Cleaning , Cutting , Bending , Binding Different Portions With Contractors Own 16 Swg Black Soft Annealed Wire , Welding With Spacer Plates Or Lugs Provided With Skirts/On Surface Of Structural Steel Members Etc . Complete , Including Cleaning Of The Surface , Scaffolding For All Heights And All Labour And As Per Drawings/Sketches , Specifications And Directions Of The Engineer-In-Charge . , Placing In Position Ms Reinforcement ( Plain Round Bars ) And/Or Tor Steel For Rcc Work Including Transporting The Steel ( Issued Free Of Cost ) From Store/Issue Points To Site Of Work , Straightening , Cleaning & Removing Oil Grease If Any , Cutting , Bending To Required Shapes & Lengths As Per Details Binding With Contractors Own 16 Swg Black Soft Annealed Binding Wire At Every Inter-Section , Supplying & Placing With Proper Over Blocks , Supports , Chairs , Overlaps , Welding , Spacers Fan Hooks Etc . ( Return All Unused/Scrapped/ Unserviceable Steel To Owners Storage Point ) For All Heights & Depths Etc . All Complete As Directed . , Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2 . 5 Sqm And Under Including Cutting The Patch In Proper Shape , Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete

Key Value

Document Fees
Refer document
EMD
INR 82000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail