| 1 | 1 | BOQ ( Sch 'A') E/M WORKS\nTaking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. | | 285 | Per point |
|---|
| 2 | 2 | Taking down carefully by unscrewing from the boards/outlets boxes fittings and fixtures such as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbed surfaces complete all as specified and directed. | | 285 | Per point |
|---|
| 3 | 3 | Taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed. | | 5 | Each |
|---|
| 4 | 4 | Taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire fro existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, oiling and greasing complete including providing flexible twin core copper conductor stranded cord from ceiling rose to connecting of fan complete all as specified and directed. | | 20 | Each |
|---|
| 5 | 5 | Supply & Fixing point wiring for one light point/ fan/ bell (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia ) with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) and sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed \n (Note:- wiring shall be done in colour coding as directed by Engineer in charge. | | 80 | Per Point |
|---|
| 6 | 6 | All as per item No.6 herein before but one socket outlet 5 pin 5 amps controlled by one switch on same board with other switchs. | | 15 | Per Point |
|---|
| 7 | 7 | All as per item No. 6 herein before One socket outlet 5 pin 5 amps controlled by one switch on independent board. | | 15 | Per Point |
|---|
| 8 | 8 | All as per item No 6 herein before but wiring with 2.5sqmm copper wire (FRLS) PVC and 1.5 sqmm earth wire for socket outlet 5 pin 15 amps on independent board. | | 10 | Per Point |
|---|
| 9 | 9 | Supply & Fixing point wiring for one light point/ fan/ bell (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including PVC casing/capping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed \n (Note:- wiring shall be done in colour coding as directed by Engineer in charge. | | 85 | Per Point |
|---|
| 10 | 10 | All as per item No.9 herein before but light point controlled by two way switch | | 10 | Per Point |
|---|
| 11 | 11 | All as per item No.9 herein before but one socket outlet 5 pin 5 amps controlled by one switch on same board. | | 30 | Per Point |
|---|
| 12 | 12 | All as per item No. 9 herein before One socket outlet 5 pin 5 amps controlled by one switch on independent board. | | 30 | Per Point |
|---|
| 13 | 13 | All as per item No 9 herein before but wiring with 2.5sqmm copper wire (FRLS) PVC and 2.5 sqmm earth wire for socket outlet 5 pin 15 amps on independent board. | | 10 | Per Point |
|---|
| 14 | 14 | Suppy & Fixing switch piano flush type single pole, one way 5 Amp complete all as specified and directed. | | 135 | Each |
|---|
| 15 | 15 | Suppy & Fixing switch piano flush type single pole, two way 5 Amp complete all as specified and directed. | | 60 | Each |
|---|
| 16 | 16 | Supply & Fixing socket out let 2 in1,3 pin, 5 and 15 Amp, flush type complete all as specified and directed. | | 20 | Each |
|---|
| 17 | 17 | Supply & Fixing ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed. | | 50 | Each |
|---|
| 18 | 18 | supply & Fixing lamp holder PVC insulated body with back plate for angle/battern fitting complete all as specified and directed | | 50 | Each |
|---|
| 19 | 19 | Supply and fixing white cover plate with frame 1 module complete all as specified and directed. | | 5 | Each |
|---|
| 20 | 20 | Supply and fixing white cover plate with frame 2 module complete all as specified and directed. | | 10 | Each |
|---|
| 21 | 21 | Supply and fixing white cover plate with frame 3 module complete all as specified and directed. | | 5 | Each |
|---|
| 22 | 22 | Supply and fixing white cover plate with frame 4 module complete all as specified and directed. | | 20 | Each |
|---|
| 23 | 23 | Supply and fixing white cover plate with frame 6 module complete all as specified and directed. | | 30 | Each |
|---|
| 24 | 24 | Supply and fixing Modular Switch1 way 6 Amp, 1 module complete all as specified and directed. | | 60 | Each |
|---|
| 25 | 25 | Supply and fixing Modular Switch1 way 10 Amp, 1 module complete all as specified and directed. | | 5 | Each |
|---|
| 26 | 26 | Supply and fixing Modular Switch1 way 16 Amp, 1 module complete all as specified and directed. | | 10 | Each |
|---|
| 27 | 27 | Supply and fixing Modular socket shuttered, 6 Amp, 2/3 pin combined 2 module complete all as specified and directed. | | 20 | Each |
|---|
| 28 | 28 | Supply and fixing Modular socket , 6/16 Amp, 2/3 pin combined 2 module complete all as specified and directed. | | 10 | Each |
|---|
| 29 | 29 | Supply & Fixing Bell push, flush type, 5 amp complete all as specified and directed . | | 5 | Each |
|---|
| 30 | 30 | Supply & Fixing modular bell push 6 amp I module complete all as specified and directed . | | 10 | Each |
|---|
| 31 | 31 | Supply & Fixing isolator TPN 415 Volts, 50 Hz, 100 Amps, 10 KA complete all as specified and directed . | | 4 | Each |
|---|
| 32 | 32 | Supply & Fixing isolator DP 240 Volts, 50 Hz, 40 Amps, 10 KA complete all as specified and directed . | | 15 | Each |
|---|
| 33 | 33 | Supply & Fixing isolator DP 240 Volts, 50 Hz, 63 Amps, 10 KA complete all as specified and directed . | | 15 | Each |
|---|
| 34 | 34 | Supply & Fixing isolator SP 05- 30 Amps, 10 KA complete all as specified and directed . | | 23 | Each |
|---|
| 35 | 35 | Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 2 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . | | 2 | Each |
|---|
| 36 | 36 | Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . | | 2 | Each |
|---|
| 37 | 37 | Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 12 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . | | 1 | Each |
|---|
| 38 | 38 | Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 2.5Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoated rates. 2. Two run of 4 sqmm, one run of 2.5 sqmm and one run of PVC conduit will be measured as one unit ie one running metre” | | 30 | Running Metre |
|---|
| 39 | 39 | Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 4.0Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoated rates. 2. Two run of 6 sqmm, one run of 4.0 sqmm and one run of PVC conduit will be measured as one unit ie one running metre” | | 20 | Running Metre |
|---|
| 40 | 40 | Supply & Fixing steped type electronic fan regulator flush type on the existing phenolic laminatedsheet etc complete all as specified and directed . | | 50 | Each |
|---|
| 41 | 41 | Material & Labour for taking out burnt/damaged winding, bushes & cleanig of stator and rotor incl etc of ceiling fans 1200mm sweep, Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length complete all as specified and directed | | 84 | Each |
|---|
| 42 | 42 | Material & Labour for taking out burnt/damaged winding, bushes & cleanig of stator and rotor incl etc of exhaust fans 300mm sweep, Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length complete all as specified and directed | | 20 | Each |
|---|
| 43 | 43 | Supply and fixing High quality T8 LED tube rod 18 watt PC base in existing 36 watt normal tube light fitting with cut off connection of existing 36 watt electronic ballast and provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter omplete all as specified and directed. Make HPL cat pat HLPT81418PC(WW) or equivalent cat part in make phillips/wippro/Bajaj, Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. | | 286 | Each |
|---|
| 44 | 44 | Supply and fixing High quality LED T5 indoor batten tube light with PC Housing fitting 1x18Watt , channel suitable forfitting of LED tube rod with standerd fittings complete all as specified and directed. Make HPL cat pat HLPT51518PCGWW or equivalent cat part in make phillips/wippro/Bajaj Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. | | 560 | Each |
|---|
| 45 | 45 | Supply and fixing Replacement of 400 watt Hi-bay light of fitting suitable for Galaxy LED Flood Lights 150 watt Pressure die-cast aluminium complete and fixing inside the hanger ht 20 mtrs complete all as specified and directed. . Make HPL cat pt No.HPLLEDFL15060D or equivalent cat par in make Phillips/Bajaj/Havells \nNote:- Testing/commissioning of lights after repair and making the lights operational to the satisfaction of Engineer in charge shall be deemed to be included in the quoted ratet and nothing extra shall be paid for the same. | | 12 | Each |
|---|
| 46 | 46 | Material & labour Servicing of indoor and outdoor unit of split type AC of 1.5/2.0/3.0 ton capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection complete all as specified and directed | | 30 | Each |
|---|
| 47 | 47 | Supply and Refilling Gas in AC 1.5 ton , 2 Ton complete all as specified and directed by Engr-in-charge. | | 10 | Each |
|---|
| 48 | 48 | Supply, fixing and commissioning of Compressor Split and window, 1.5 ton AC complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 49 | 49 | Supply, fixing and commissioning of Compressor Split and window, 2 ton complete all as specified and directed by Engr-in-charge. | | 3 | Each |
|---|
| 50 | 50 | Supply, fixing and commissioning of AC relay split and window complete all as specified and directed by Engr-in-charge. | | 4 | Each |
|---|
| 51 | 51 | Supply, fixing and commissioning PCB of split/window AC complete all as specified and directed by Engr-in-charge. | | 4 | Each |
|---|
| 52 | 52 | Supply, fixing and commissionin Condenser 50 mfd complete all as specified and directed by Engr-in-charge. | | 6 | Each |
|---|
| 53 | 53 | Supply, fixing and commissioninRefrigeratgor 65 to 180 ltr relay complete all as specified and directed by Engr-in-charge. | | 3 | Each |
|---|
| 54 | 54 | Supply, fixing and commissionin Refrigeratgor 200 to 310 ltrs relay complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 55 | 55 | Supply and Refilling Refrigerator gas having capacity 65 to 180 ltrcomplete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 56 | 56 | Supply and Refilling Refrigerator gas having capacity 200 to 310 ltrs complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 57 | 57 | Supply, fixing and commissioni Refrigerator compressor of capacity 65 to 180 ltr complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 58 | 58 | Supply, fixing and commissioni Refrigerator compressor of capacity200 to 310 ltrs complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 59 | 59 | Supply and fixing Thermostat of AC any capacity complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 60 | 60 | Supply and fixing Thermostat of Refrigerator any capacity complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 61 | 61 | Supply, fixing and commissionin Water cooler compressor of capacity 40/80 complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 62 | 62 | Supply, fixing and commissionin Water cooler compressor of capacity r 60/120 complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 63 | 63 | Supply and Refilling Water cooler Gas charging of capacity 40/80 complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 64 | 64 | Supply and Refilling Water cooler Gas charging of capacity 60/120 complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 65 | 65 | Supply and fixing Thermostat of Water cooler theremostate of any capacity complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 66 | 66 | Supply and fixing Water cooler PVC pipe complete all as specified and directed by Engr-in-charge. | | 4 | Each |
|---|
| 67 | 67 | Supply and fixing blead with motor Split AC of capacity 1.5 TR complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 68 | 68 | Supply and fixing blead with motor Split AC of capacity 2 TR complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 69 | 69 | Supply and fixing motor Fan motor window AC of any capacity complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 70 | 70 | Supply and fixing motor Fan motor Water cooler of capacity 40/80 ltrs complete all as specified and directed by Engr-in-charge. | | 2 | Each |
|---|
| 71 | 71 | Supply and fixing motor Fan motor Water cooler of capacity 60/120 ltrs.complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 72 | 72 | Supply and fixing Outdoor condenser split AC 1.5 TR complete all as specified and directed by Engr-in-charge. | | 3 | Each |
|---|
| 73 | 73 | Supply and fixing Fan blead of split AC complete all as specified and directed by Engr-in-charge. | | 3 | Each |
|---|
| 74 | 74 | Supply and fixing Revarse wall of AC/freez/water cooler. complete all as specified and directed by Engr-in-charge. | | 8 | Each |
|---|
| 75 | 75 | Supply and fixing suction motor split AC complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 76 | 76 | Supply and fixing Window AC cooling coil complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 77 | 77 | Supply and fixing Spilit AC cooling coil complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|
| 78 | 78 | Supply and fixing Fan blead window AC complete all as specified and directed by Engr-in-charge. | | 1 | Each |
|---|