Replacement Of Old Vintage Ht Four Pole Structure With Rmu Inside Ins Virbahu And Provision Of Deficient Power Supply For Mi Room P 57 At Ins Satavahana And Building No P 12 At Naval Base Under Age Em I Of Ge Utility 1 Visakhapatnam , Dismantling Old Defective Four Pole Structure Complete Including Steel Poles , Cross Arms Etc Complete And Removing From Site Complete All As Directed , Supply , Installation , Testing & Commissioning Of 11 Kv , 630A , 21Ka/3Sec , Outdoor Type , Both Sides Extensible , Internal Arc 21Ka For 1 Sec For Tank , Floor Mounted With Internal Copper Bus Bars , Sf6 Insulated , Completely Motorised , 6 Way Rmu Consisting Of 2 Nos Lbs As Incomer & 4 Nos 630A Vcbs As Outgoing With Sacada Compatable Overload And Eart Fault Protection Relay ( Ashidha / Cspdr ) With Air Insulated Metering Module ( Mfm For Vcb Feeders ) . All Live Parts , Bus Bars , Lbss Connections Of Rmu Shall Be Enclosed In One Sf6 Tank To Avoid Multiple Intercon, Garrison Engineer Utility-I Visakhapatnam-Andhra Pradesh

Statutory Bodies & Commissions/Committees has published Replacement Of Old Vintage Ht Four Pole Structure With Rmu Inside Ins Virbahu And Provision Of Deficient Power Supply For Mi Room P 57 At Ins Satavahana And Building No P 12 At Naval Base Under Age Em I Of Ge Utility 1 Visakhapatnam , Dismantling Old Defective Four Pole Structure Complete Including Steel Poles , Cross Arms Etc Complete And Removing From Site Complete All As Directed , Supply , Installation , Testing & Commissioning Of 11 Kv , 630A , 21Ka/3Sec , Outdoor Type , Both Sides Extensible , Internal Arc 21Ka For 1 Sec For Tank , Floor Mounted With Internal Copper Bus Bars , Sf6 Insulated , Completely Motorised , 6 Way Rmu Consisting Of 2 Nos Lbs As Incomer & 4 Nos 630A Vcbs As Outgoing With Sacada Compatable Overload And Eart Fault Protection Relay ( Ashidha / Cspdr ) With Air Insulated Metering Module ( Mfm For Vcb Feeders ) . All Live Parts , Bus Bars , Lbss Connections Of Rmu Shall Be Enclosed In One Sf6 Tank To Avoid Multiple Intercon. Submission Date for this Tender is 19-09-2019. Angle Tenders in Garrison Engineer Utility-I Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21776632
Replacement Of Old Vintage Ht Four Pole Structure With Rmu Inside Ins Virbahu And Provision Of Deficient Power Supply For Mi Room P 57 At Ins Satavahana And Building No P 12 At Naval Base Under Age Em I Of Ge Utility 1 Visakhapatnam , Dismantling Old Defective Four Pole Structure Complete Including Steel Poles , Cross Arms Etc Complete And Removing From Site Complete All As Directed , Supply , Installation , Testing & Commissioning Of 11 Kv , 630A , 21Ka/3Sec , Outdoor Type , Both Sides Extensible , Internal Arc 21Ka For 1 Sec For Tank , Floor Mounted With Internal Copper Bus Bars , Sf6 Insulated , Completely Motorised , 6 Way Rmu Consisting Of 2 Nos Lbs As Incomer & 4 Nos 630A Vcbs As Outgoing With Sacada Compatable Overload And Eart Fault Protection Relay ( Ashidha / Cspdr ) With Air Insulated Metering Module ( Mfm For Vcb Feeders ) . All Live Parts , Bus Bars , Lbss Connections Of Rmu Shall Be Enclosed In One Sf6 Tank To Avoid Multiple Intercon
Open Tender
Indian
Andhra Pradesh
Garrison Engineer Utility-I Visakhapatnam
19-09-2019

Tender Details

Corrigendum - Replacement Of Old Vintage Ht Four Pole Structure With Rmu Inside Ins Virbahu And Provision Of Deficient Power Supply For Mi Room P 57 At Ins Satavahana And Building No P 12 At Naval Base Under Age Em I Of Ge Utility 1 Visakhapatnam , Dismantling Old Defective Four Pole Structure Complete Including Steel Poles , Cross Arms Etc Complete And Removing From Site Complete All As Directed , Supply , Installation , Testing & Commissioning Of 11 Kv , 630A , 21Ka/3Sec , Outdoor Type , Both Sides Extensible , Internal Arc 21Ka For 1 Sec For Tank , Floor Mounted With Internal Copper Bus Bars , Sf6 Insulated , Completely Motorised , 6 Way Rmu Consisting Of 2 Nos Lbs As Incomer & 4 Nos 630A Vcbs As Outgoing With Sacada Compatable Overload And Eart Fault Protection Relay ( Ashidha / Cspdr ) With Air Insulated Metering Module ( Mfm For Vcb Feeders ) . All Live Parts , Bus Bars , Lbss Connections Of Rmu Shall Be Enclosed In One Sf6 Tank To Avoid Multiple Interconnections . Sf6 Tank Shall Be Sealed For Life Robotically Welded Non Magnetic And Non Ferrite Stainless Steel Grade 304 Of Minimum 2 . 5 Mm Thick Having Ip67 Degree Of Protection Filled With Sf6 Gas As Insulation With Leakage Rate Less Than 0 . 1% Per Year Tested As Per Iec 62271-200 . Manual Welding Or Hermetic Sealing Of Tank Shall Be Not Be Accepted . , The Unit Shall Have Front Cable Entry For Ease Of Installation And Shall Have Site Replaceable Bushings For Ease Of Troubleshooting During Breakdown . Rmu Should Be Complete With All Accessories Such As Terminal Boots , Vpis , Cable Supports , All Front Cable Terminations , Mechanical Indications For Load Break Switch On/Off , Manometer As Per With Iec Standards 62271-200 , 60056 , 60129 , 60265 , 60298 , 60420 , 60529 And 60694 . Altitude Of Installation Up To 1000M As Per Iec 60120 . , Note:- Bushings Bolted Type Top Mounted Outside The Tank For Connection Of External Bus Bar . Also , The Outer Enclosure Shall Cover The Full Length Of The Switchgear , To Ensure Ip3x+Ip54 Protection For Cable Boxes . The Unit Shall Be Internal Arc Proof 21Ka For 1 Se With Aflr Clasification . , Tested And Totally Safe For Human Beings . The Gas Release & Personnel Safety From Internal Arc Shall Not Depend On Plinth Design . The Release Of Gas To Be From The Top Of The Unit , So That , Even If The Person Is Operating The Unit , Opening The Cover , & There Are Personnels Near The Sides Of The Rmu/Plinth , Top Release Will Ensure Their Safety . The Hot Gas Release , In Case Of An Internal Arc , In No Case Should Be From Any Side Or Bottom Of The Unit , As The Same Is Unsafe For The Operating Personnel/Pedestrian Or General Public . Bidder Shall Provide Type Test Report To Prove Compliance To The Internal Arc Fault Iac-Aflr As Per Iec 62271-200 . Internal Arc Testing Shall Be Done With Enclosure Door In Open Condition , With Switching Devices In Operation Mode As Per Specified Standard . Complete All As Directed Of Make : Schneider / Abb Safe Plus/ Siemens . , Note:-The Rate Quoted Deemed To Be Inclusive Of Necessary Earth , Feeders Snickering Marking & Foundation For Installation Of Rmu All As Per Manufactures Recommendations/ Instructions . , Supply And Laying Or Fixing Or Passing Through Pipe Or In Cable Ducts , 11000 Volts Grade Xlpe Insulated Heavy Duty ( Earthed ) , Screened , Pvc Bedded , Galvanised Steel Strip Or Wire Armoured , Electric Power Cables ( Heavy Duty ) With Aluminium Conductor 185 Sq Mm 3 Core Size Including Dismantling Old One . Make : Polycab/Havells/Finolex . , Supply And Fix Cable Jointing Kit For 11 Kv Grade Cable For Outdoor Terimination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Al Conducter Cable Of Size 185 Sq Mm . Make: Birla 3M/ Raychem/ Denson , Supply And Fix Cable Jointing Kit For 11 Kv Grade Cable For Indoor Terimination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Al Conducter Cable Of Size 185 Sq Mm . Make: Birla 3M/ Raychem/ Denson , Excavating In Trenches N . Exc . 1 . 5M Wide And N . Exc . 1 . 5M In Depth For Foundation , Trenches For Laying Cables/ Pipe Line Etc . And Getting Out In Soft/Loose Soil , Removing Excavated Materials To A Distance N . Exc . 50M And Depositing Where Directed At A Level N . Exc 1 . 50M Above The Starting Point . , Returning , Filling In Including Spreading Leveling Watering And Well Ramming In Layers Not Exc 25Cm In Any Type Of Soil . , Supply And Spreading Clean Dry Sand For Cable Cushioning In Trenches Complete All As Specified And As Directed . ( Note: Punned Thickness Only Shall Be Measured ) , Cutting & Cleaning Of Bushes/Small Plants , At Sub Stn Incl Surface Dressing And Removing Debris To Distance Not Exc 50 Mtr Complete , Hardcore Of Guage Exc 63Mm But N Exc . 100 Mm , Deposited , Spread And Levelled In Layers N Exc . 15 Cm Thick , Watered And Rolled/Rammed To A True Surface Complete All As Directed , Hardcore Of Gauge N Exc . 63 Mm , Deposited , Spread And Levelled In Layers N Exc . 15 Cm Thick , Watered And Rammed To A True Surface Complete All As Directed , S&F Ms Angles , Bars Flats Etc , As In Supports For Stiffening Of Fencing , Wall Ties , Hold Fasts , Clamps And Similar Small Articles Confirming To Fe 410-0 Or Fe 310-0 Complete , Preparation Of New Or Previously Untreated Steel Surfaces Of Any Description , Over 10 Cm Width Or Grith , Not Otherwise Described And Appling Two Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromer Primer Complete . , Supply And Laying Un-Reinforced Pre Cast Cover Of Size ( 300Mmx180mmx40mm ) Laid Along Alignment Of Cable As Protection To Cable In Trenches Complete All As Specified And Directed By Engineer-In-Charge , Supply And Fix Or Laid In Road Crossing/ Fixed To Poles , Gi Pipe Of 100 Mm Size Light Grade For Protection Of Cable Complete All As Directed . Make: Tata / Jindal , M &L Plain Cement Concrete 1:4:8 Type C2 ( Using 40 Mm Aggregrate ) As In Foundations Filling Mass Concrete Complete All As Specified And Directed , M &L For Cement Concrete Pcc 1:2:4 Type B1 ( Using 20 Mm Aggregrate ) As Coping Of Poles Complete All As Specified And Directed , Supply And Fix Or Laid In Road Crossing/ Fixed To Poles , Gi Pipe Of 80 Mm Size Light Grade For Protection Of Cable Complete All As Directed Make: Tata / Jindal , Making Trench Through Horizontal Earth Boaring For Road/ Foot Path /Hard Standing/Culvert Etc For Inserting Gi Protection Pipe For Drawing Of Cable And Complete All As Directed . , Cutting Trench Through Road/ Wall To A Width Of 20Cm And Depth Of 30Cm For Inserting Gi Protection Pipe For Drawing Cable And Filling Back The Trench With Pcc 1:3:6 Type C1 Complete All As Directed . , M&L For Earthing Complete With Galvanised Steel Earthplate Of Size 60X60cmx6 . 3Mm Thick Electrode And 32X6mm Gi Strip As Earth Lead , Buried Directly In Ground ( Earth Pit Not Less Than 2 . 25M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1 . 5M Below Ground Level , Connected To 32X6mm Earth Strip By Means Of Nuts , Bolts , Check Nuts And Washers Of Gi All As Shown In Electrical Plate No . 5 Of Ssr Part-I , Connected To Earth Test Terminal Point All As Specified Or As Indicated Including Testing On Completion ( Rates Inclusive Of Neccessary Excavation In Any Type Of Soil , Earth Work , Pcc Pit , Ci Cover , Funnel With Watering Pipe , Suitable Size Of Light Grade Gi Protection Pipe For Earth Strip In Ground Etc . All As Required At Site For Complete Earthing ) , Supply& Fix Aluminium Strip 32 Mmx 6 Mm Complete With Saddles And Fixing Screws For Fitting The Strip , Supply And Laying Sub Class B Bricks Of Old Size ( 23X11x7cm ) Laid Along Alignment Of Cable As Protection To Cable In Trenches Complete All As Specified And Directed By Engi

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-