Sales : +91-777 804 8217
| Name of Work: REPAIR / REPLACEMENT OF OLD EXISTING ALUMINIUM WIRING TO COPPER WIRING INCL FITTING AND FIXTURE FOR AND REPAIR TO FAN AND SUMMER / WINTER APPLINANCES OF MD ACCN AND OFFRS ACCN IN MIL STN BANBASA UNDER GE (MES) PITHORAGARH. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Taking down carefully copper/aluminium point wiring ( light, fan, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, etc, removing materials to store for keeping in safe custody or for taking credit as per schedule and making good disturbed surfaces of walls, floors, ceiling etc to match the existing surfaces complete all as specified and directed. | 1 | 1135 | Per Point |
| 2 | 2 | Taking down carefully by disconnecting electrical connection, main switches / distribution board / MCB DB with MCBs of any rating, removing dismantled material from site and making good disturbed surface of walls to match with existing complete all as specified and directed. | 2 | 80 | Each |
| 3 | 3 | Dismantling and taking out sub main wiring / service wire/ UG cable of any size and taking out from sitecomplete all as specified and directed. | 3 | 492 | RM |
| 4 | 4 | M & L for point wiring complete with 1.5 Sqmm single core multi- stranded copper conductor PVC insulated and unsheathed fire retardant (FR) cable 1100 volts grade IS-694 (ISI marked) drawn through and including PVC conduit heavy duty 20/25 mm dia and all necessary fittings accessories fixed concealed in walls/ceiling etc including shunk type pressed steel terminal boxes with 3.00 mm thick insulated laminated sheet / hylem top covers and 1.5 Sqmm PVC insulated unsheathed fire retardant (FR) cable 1100 volts grade with multi stranded copper conductors earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed for the following :- \nNote:- Cutting chases in walls/ceiling to conceal the conduits etc and making good surface to match the existing surfaces is included in unit rate.\n\n\n\n\n\n | 4 | ||
| 5 | 4.01 | (a) One light / fan / bell point controlled by one, one way switch 6 Amps. | 5 | 300 | Per Point |
| 6 | 4.02 | (b) One light point controlled by two way switch 6 Amps. | 6 | 15 | Per Point |
| 7 | 4.03 | (c) One 6 Amps socket outlet on the independent board. | 7 | 100 | Per Point |
| 8 | 4.04 | (d) One 6 Amps socket outlet on the same board with other switches. | 8 | 50 | Per Point |
| 9 | 5 | ~Ditto~ all as described in Srl item No. 4 here-in-before but point wiring with 2.50 Sqmm single core multi- stranded copper conductor cable fire- retardant (FR) and 2.5 Sqmm PVC insulated and unsheathed fire retardant (FR) cable conductor 1100 volts grade with multi- stranded copper conductor as earth wire for one 3/5 pin, 15/16 Amps switch socket combination point on independent board complete all as specified and direted | 9 | 100 | Per Point |
| 10 | 6 | M & L for point wiring complete with 1.5 Sqmm single core multi- stranded copper conductor PVC insulated and unsheathed fire retardant (FR) cable 1100 volts grade, IS-694 (ISI marked) drawn through surface condiut including PVC conduit 20/25mm dia and all necessary fittings accessories fixed on walls/ceiling etc including shunk type pressed steel terminal boxes with 3.00 mm thick insulated laminated sheet / hylem top covers and 1.5 Sqmm PVC insulated unsheathed fire retardant (FR) cable 1100 volts grade with multi stranded copper conductors earth continuity conductor to common earth and connected to earth dolly complete all as specified and direted for the following :- \n | 10 | ||
| 11 | 6.01 | (a) One light / fan / bell point controlled by one, one way switch 6 Amps. | 11 | 150 | Per Point |
| 12 | 6.02 | (b) One light point controlled by two way switch 6 Amps. | 12 | 10 | Per Point |
| 13 | 6.03 | (c) One 6 Amps socket outlet on the independent board. | 13 | 50 | Per Point |
| 14 | 6.04 | (d) One 6 Amps socket outlet on the same board with other switches. | 14 | 25 | Per Point |
| 15 | 7 | ~Ditto~ all as described in Srl item No.6 here-in-before but point wiring with 2.50 Sqmm single core multi- stranded copper conductor cable fire- retardant (FR) and 2.5 Sqmm PVC insulated and unsheathed fire retardant (FR) cable conductor 1100 volts grade with multi- stranded copper conductor as earth wire for one 3/5 pin, 15/16 Amps switch socket combination point on independent board complete all as specified and directed | 15 | 50 | Per Point |
| 16 | 8 | M & L point wiring complete with 1.5 Sqmm single core multi- stranded copper conductor PVC insulated and unsheathed fire retardant (FR) cable 1100 volts grade, IS-694 (ISI marked) drawn through existing PVC conduit including shunk type pressed steel terminal boxes with 3.00 mm thick insulated laminated sheet / hylem top cover and 1.5 Sqmm PVC insulated unsheathed fire retardant (FR) cable 1100 volts grade with multi stranded copper conductors earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed for the following :- \n | 16 | ||
| 17 | 8.01 | (a) One light / fan / bell point controlled by one, one way switch 6 Amps. | 17 | 150 | Per Point |
| 18 | 8.02 | (b) One light point controlled by two way switch 6 Amps. | 18 | 10 | Per Point |
| 19 | 8.03 | (c) One 6 Amps socket outlet on the independent board. | 19 | 50 | Per Point |
| 20 | 8.04 | (d) One 6 Amps socket outlet on the same board with other switches. | 20 | 25 | Per Point |
| 21 | 9 | ~Ditto~ all as described in Srl item No.8 here-in-before but point wiring with 2.50 Sqmm single core multi- stranded copper conductor cable fire- retardant (FR) and 2.5 Sqmm PVC insulated and unsheathed fire retardant (FR) cable conductor 1100 volts grade with multi- stranded copper conductor as earth wire for one 3/5 pin, 15/16 Amps switch socket combination point on independent board complete all as specified and directed. | 21 | 50 | Per Point |
| 22 | 10 | S & F switch piano flush button single pole one way 6 Amps complete all as specified and directed. | 22 | 850 | Each |
| 23 | 11 | S & F switch piano flush button 6 Amps, two way complete all as specified and directed. | 23 | 70 | Each |
| 24 | 12 | S & F socket outlet 3 pin 5 Amps flush type complete all as specified and directed. | 24 | 300 | Each |
| 25 | 13 | S & F switch piano flush button single pole one way 15 Amps flush type complete all as specified and directed. | 25 | 200 | Each |
| 26 | 14 | S & F socket outlet 2 in 1, 3 pin, 5 Amp and 15 Amp flush type universal complete all as specified and directed. | 26 | 200 | Each |
| 27 | 15 | S & F ceiling rose 3 terminal / PVC / Polycarbonate, isolated body complete all as specified and directed. | 27 | 275 | Each |
| 28 | 16 | S & F switch bell push flush type suitable for bell one way 5/6 Amps complete all as specified and directed. | 28 | 50 | Each |
| 29 | 17 | Re-Fixing and connecting electric energy meter upto 30 Amps, removed in item No. 1 above complete all as specified and directed. | 29 | 5 | Each \nJob |
| 30 | 18 | S & F in replacement LED T-5 tube light fitting single tube, box type surface mounted, (1x18 Watt) complete, spring loaded rotar type lamp holder,Electronic driver, connector block etc with LED tube rod 18 W, pre-wired including making necessary electrical connection with three core copper flexible wire of 0.50 Sqmm from ceiling rose to tube light fitting & fixing arrangement including taking down existing unserviceable tube light fitting, deposited to MES store yard or for taking credit as per schedule complete all as specified and directed. \nMake:- Philips/ Bajaj / HPL | 30 | 600 | Each |
| 31 | 19 | Supply and Fixing in replacement of 9 Watt LED tube light fitting single tube, box type surface mounted, (1x 9 Watt) complete , spring loaded rotar type lamp holder, connector block etc. with LED tube rod 9 W ,prewired including making necessary electrical connection with three core copper flexible wire of 0.50 Sqmm from ceiling rose to tube light fitting complete including taking down of existing unserviceable tube light fitting, deposited to MES store yard or for taking credit as per schedule complete all as specified and directed. \nMake :- Philips / Bajaj / HPL | 31 | 100 | Each |
| 32 | 20 | Supply and fix in repair LED bulb 12W, B-22 base type for batten / angular lamp holder complete all as specified and directed. \nMake - HPL / Philips / Bajaj | 32 | 190 | Each |
| 33 | 21 | Supply and fix in repair LED bulb 7W B22 base type for batten/angular lamp holder lamp holder complete all as specified and directed. \nMake :- HPL / Philips / Bajaj | 33 | 175 | Each |
| 34 | 22 | Supply and fix in replacement LED bulk head fittings, suitable for 10 Watt with accessories, deep drawn anodised aluminium body, heat resistant prismatic glass cover with specifically designed 10 Watt and making electrical connection etc complete all as specified and directed.\nMake :- HPL / Philips / Bajaj | 34 | 5 | Each |
| 35 | 23 | S & F in repair five stepped 120 W electronic fan regulator flush type unbreakble rotary switch on existing laminated sheet including necessary connection complete all as specified and directed | 35 | 70 | Each |
| 36 | 24 | S & F in repair electronic bell Ding Dong , AC 230 Volt, single pole of approved make complete all as specified and directed. | 36 | 50 | Each |
| 37 | 25 | S & F in repair bell Multi Music type,AC 230 V, single pole of approved make complete all as specified and directed. | 37 | 10 | Each |
| 38 | 26 | S & F sheet metal enclosure double door for DB, SPN 4 way with 200 amps rated bus bar, 240 volts, suitable for housing MCB`s complete all as specified and directed. | 38 | 25 | Each |
| 39 | 27 | S & F sheet metal enclosure double door for DB, SPN 8 way with 200 amps rated bus bar, 240 volts, suitable for housing MCB`s complete all as specified and directed. | 39 | 55 | Each |
| 40 | 28 | S & F MCB SPN, 240 Volts,40 Amps, 10KA ‘C’ series complete all as specified and directed.\nMake : L&T / Schnider / Indonasian | 40 | 30 | Each |
| 41 | 29 | S & F MCB SPN, 240 Volts, 63 Amps, 10KA ‘C’ series complete all as specified and directed.\nMake : L&T / Schnider / Indonasian | 41 | 60 | Each |
| 42 | 30 | S & F MCB SP, 240 volts,6 to 40 Amps, 10 KA ‘C’ series complete all as specified and directed\n.Make : L&T / Schnider / Indonasian | 42 | 400 | Each |
| 43 | 31 | S & F MCB SP, 240 volts, 40 to 63 Amps, 10 KA ‘C’ series complete all as specified and directed.\nMake : L&T / Schnider / Indonasian | 43 | 60 | Each |
| 44 | 32 | S & F in repair post top lantern light for 1 x 18 Watt LED lamp complete with all accessories including lamp complete all as specified and directed. | 44 | 2 | Each |
| 45 | 33 | S & F in repair lamp holder PVC / Polycarbonate with metal ring for fixing of B-22 base lamp with back plate suitable for batten fittings complete all as specified and directed.\n Make : Anchor / Kona / Kinjal | 45 | 365 | Each |
| 46 | 34 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, laying of cables etc and getting out in soft / loose soil complete all as specified and directed. | 46 | 33.75 | Cum |
| 47 | 35 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. | 47 | 16.43 | Cum |
| 48 | 36 | Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. | 48 | 17.33 | Cum |
| 49 | 37 | M & L dry sand cushioning to underground cables in layer (8cm thick before laying of cables and 15cm thick after laying and stretching of cable) as in trenches for cable protection or under floor or in foundation and gentally hand ramming and consolidation complete all as specified and directed. \nNote:- Sand thickness shall be measured only 18 cm after punning . | 49 | 15.53 | Cum |
| 50 | 38 | M & L for brick protection cover of UG cable using old size sub class 'B' common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of the brick, the gap between adjacent bricks not exceeding 10 mm complete all as specified and directed. | 50 | 1.2 | Per 1000 Nos |
| 51 | 39 | M & L for 40 mm dia bore galvanized iron tubing, light grade, ISI Marked, for protection of cable fixed to pole / wall or laid in floors/road crossing ducts with all necessary fittings like clamps, bolts, nuts and washers etc complete all as specified and directed. | 51 | 80 | RM |
| 52 | 40 | S & F pendent ordinary comprising ceiling rose brass with insulated body lamp cord, grip pattern and 0.5 Sqmm copper flexible twisted twin core cable upto 1.5 m length complete all as specified and directed. | 52 | 15 | Each |
| 53 | 41 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia Protected by light grade GI Pipe 15 mm dia and 20 mm dia for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed. | 53 | 20 | Each \n |
| 54 | 42 | ~Ditto~ all as per item No. 41 above but using galvanized iron strip 32 x 6 mm as earthing lead with protection pipe light grade 40 mm dia complete | 54 | 2 | Each |
| 55 | 43 | S & F sub main wiring with two single run of 6 Sqmm single core unsheathed PVC insulated fire retardant (FR) cable, 1100 volts grade multi stranded copper conductor drawn through in & including PVC conduit of 25 mm or higher dia including all necessary conduit accessories, surface type including one run of 4 Sqmm stranded copper conductor PVC insulated fire retardant (FR) cable as earth wire connected to common earth dolly, complete all as specified and directed. | 55 | 100 | RM |
| 56 | 44 | Supply, laying & testing for XLPE Cable size 25 Sqmm nominal cross section x 3.5 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete all as specified and directed . \nNOTE:- Excavation & eartwork shall be measured and paid separately under respective items | 56 | 70 | RM |
| 57 | 45 | Supply, laying & testing for XLPE Cable size 35 Sqmm nominal cross section x 3.5 core insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete all as specified and directed . \nNOTE:- Excavation & eartwork shall be measured and paid separately under respective items | 57 | 50 | RM |
| 58 | 46 | S & F in repair security light luminaire comprising of epoxy powder coated housing enclosed with glass cover in frame 20 x 1.2 W for BSLST 20 LED suitable for 25 to 40 mm dia pipe 1.2 mtr long including clamps, nut & bolts etc and making electric connection with 2 core 1.5 Sqmm PVC copper conductor cable complete all as directed by Engr-in-Charge. \nMake:- Philips / Bajaj / HPL | 58 | 30 | Each |
| 59 | 47 | S & F in replacement single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB for 20 Amps, 240 Volt complete all as specified and directed. | 59 | 20 | Each |
| 60 | 48 | S & F Service connection with PVC insulated and PVC sheathed flat twin core electric cable of 16 Sqmm cross sectional area stranded aluminium conductor, 1100V grade heavy duty, served all PVC sheathed in service connections, suspended by insulating hangers not more than 1 Mtr apart including 4 mm dia GI suspension wire and loop insulators complete all as specified and directed. | 60 | 200 | RM |
| 61 | 49 | S & F in replacement rigid PVC conduit pipe medium grade 25 mm bore including junction / terminal boxes, tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts saddles etc complete all as specified and directed. | 61 | 50 | RM |
| 62 | 50 | Taking out sealed compressor unit from 286/300/310 litres capacity refrigerator, cutting the dome and overhauling of the unit complete and replacement of unserviceable parts, rewinding the stator with suitable size super enamelled copper winding wire using best quality insulating materials re-assembing the unit, welding the dome after complete repairs, installing the unit with gas to its full capacity, installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed.\nNote:- New parts replaced shall be measured and paid separately under respective items of schedule 'A'. | 62 | 2 | Each |
| 63 | 51 | M & L for flushing the line by CTC and connecting the unit complete, repairing the leaking tube / lines by brazing and charging the unit with compressor oil and refrigerator gas to its full capacity, commissioning and testing for its smooth functioning all as specified and directed | 63 | 2 | Each |
| 64 | 52 | S & F in replacement Neoprene door gasket of refrigerator of any make and capacity including re-alignment of door complete all as specified and directed | 64 | 2 | Each |
| 65 | 53 | S & F in replacement thermostat switch suitable for refrigerator of any capacity and make complete all as specified and directed. | 65 | 3 | Each |
| 66 | 54 | S & F in replacement relay assembly suitable for refrigerator of any size and make compelete all as specified and directed | 66 | 3 | Each |
| 67 | 55 | S & F in replacement door for freezer suitable for refrigerator of any make and capacity 310/300/286 litres complete all as specified and directed. \nMake:- Jyoti / classic | 67 | 1 | Each |
| 68 | 56 | S & F in replacement glass cover for vegetable tray of any size for 165/286/300/310 ltrs capacity refrigerator of approved make complete all as specified and directed | 68 | 3 | Each |
| 69 | 57 | S & F in replacement lamp holder suitable for 15 watt bulbs screw / pin type complete all as specified and directed | 69 | 3 | Each |
| 70 | 58 | S & F in replacement electric bulb 250 Volts 15 watts screw / pin type as required for any make and capacity of refrigerators complete all as specified and directed. | 70 | 3 | Each |
| 71 | 59 | S & F in replacementchiller tray for any make of refrigerator of capacity 310/300/286 litres complete all as specified and directed. | 71 | 2 | Each |
| 72 | 60 | S & F in replacement over load protector suitable for refrigerator of any make and capacity complete all as specified and directed. | 72 | 4 | Each |
| 73 | 61 | S & F in replacement compressor unit of refrigerator of any make and capacity of 286/310 litres complete all as specified and directed. \nNote : Compressor unit shall be of Tecumsch make. | 73 | 1 | Each |
| 74 | 62 | S & F in replacement ice cube tray of approved make complete all as specified and directed | 74 | 3 | Each |
| 75 | 63 | S & F in replacement condensor of refrigerator of any make but suitable for refrigerator of capacity 286/310 litres complete all as specified and directed. | 75 | 2 | Each |
| 76 | 64 | M & L for denting brazing, replacement of bottom rusted parts by welding MS sheet of existing suitable thickness with and including replacement of door handle, scraping out old paint by burning and then applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer of approved make/colour over compressor and body of the refrigerator inclduing preparation of surfaces complete all as specified and directed | 76 | 2 | Each |
| 77 | 65 | M & L for in repair flushing the complete refrigerating system with CTC the leaking pipe lines by brazing and charging the unit with compressor oil and refrigerator gas to its full capacity after evacuating and cleaning the complete system installing commissioning and testing for its smooth functioning for 72 Hrs on load complete all as specified and directed. | 77 | 1 | Each |
| 78 | 66 | S & F in replacement relay of suitable size for 1.5 Ton capaicty window/Split type AC of any make, complete all as specified and directed. \nMake : Renuttral / classic / Anupurna | 78 | 1 | Each |
| 79 | 67 | S & F in replacement thermostat switch of suitable size for window/split type AC 1.5 Ton capcity of any make and capacity,complete all as specified and directed. \n | 79 | 1 | Each |
| 80 | 68 | S & F in replacement air / dust filter suitable for 2.5/2.0/1.5 Ton capacity split/ window type AC of any make complete all as specified and directed. | 80 | 1 | Each |
| 81 | 69 | S & F in replacement running capacitor suitable for 1.5 Ton capacity window /Split type AC of any make, complete all as specified and directed. \n | 81 | 1 | Each |
| 82 | 70 | S & F in replacement over load protector for 2.5/2.0/1.5 Ton capacity window/split type AC of any make, complete all as specified and directed. | 82 | 1 | Each |
| 83 | 71 | S & F in replacement starting capacitor of required mfd suitable for 2.5/2.0/1.5 Ton capacity split / window type AC of any make, complete all as specified and directed.\n | 83 | 1 | Each |
| 84 | 72 | S & F in replacement fan motor of Air Conditioner of 1.5/1.0 ton capacity of make kirlosker or equivalentfor window/split type of any make make complete all as specified and directed. | 84 | 1 | Each |
| 85 | 73 | S & F in replacement blower motor blade suitable for 1.5/1.0 Ton capacity Split/window type AC of any make, complete all as specified and directed | 85 | 1 | Each |
| 86 | 74 | S & F in replacement capacitor of required mfd suitable for blower motor of AC of any make& type,complete all as specified and directed | 86 | 1 | Each |
| 87 | 75 | S& F in replacement for rewiring of window/split type AC with PVC copper conductor cables of required size, complete all as specified and directed. | 87 | 1 | Each |
| 88 | 76 | S & F in replacement Selector switch AC 230 Volts suitable for AC 1.5/2.0 ton capacity of existing size and capacity complete all as specified and directed. | 88 | 1 | Each |
| 89 | 77 | S & F in replacement compressor unit for AC 1.5 Ton capacity single phase 240 Volts complete all as specified and directed. \n | 89 | 1 | Each |
| 90 | 78 | S & F in replacement front grill assembly of existing size for window type AC of 1.5 ton capacity complete all as specified and directed | 90 | 1 | Each |
| 91 | 79 | Taking out sealed compressor unit water cooler of any make, storage capacity 120 litres and cooling capacity 60 litres per hour from the machine, cutting the dome and overhauling of the water cooler and replacement of unserviceable parts, rewinding the stator with suitable size super enamelled copper winding wire using the best quality insulating material, re-assembing the unit, welding the dome after complete repairs, installing the unit with machine, charging with compressor oil and refrigerator gas to its full capacity, installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed. \nNote :- New parts replaced shall be measured and paid seperately under respective items of Sch 'A' | 91 | 2 | Each |
| 92 | 80 | ~Ditto~ all as per Srl item No. 79 above but storage capacity of water cooler 80 litres and cooling aapacity 40 litres per hour. | 92 | 2 | Each |
| 93 | 81 | M & L for in reapir flushing out the complete system by CTC, repairing the leaking pipe joint by brazing and charging the unit with compressor oil and refrigerator gas after evacuating and flushing of water cooler having 120 litres storage capacity and 60 litres cooling capacity of any make, complete all as specified and directed. | 93 | 3 | Each |
| 94 | 82 | ~Ditto~ all as per Srl item No. 81 above but storage capacity of water cooler 80 litres and cooling capacity 40 litres. | 94 | 3 | Each |
| 95 | 83 | S & F in replacement running capacitor of required mfd suitable for water cooler of any make and capacity all as specified and directed. | 95 | 3 | Each |
| 96 | 84 | S & F in replacement starting capacitor of required mfd suitable for water cooler of any make and capacity all as specified and directed. | 96 | 3 | Each |
| 97 | 85 | S & F in replacement kit relay assembly suitable for water cooler of any make and cpacity all as specified and directed. | 97 | 3 | Each |
| 98 | 86 | S & F in replacement over load protector suitable for water cooler of any make and capacity all as specified and directed | 98 | 3 | Each |
| 99 | 87 | S & F in replacement thermostat switch of suitable size for water coolers as per existing,any make and capacity all as specified and directed. | 99 | 4 | Each |
| 100 | 88 | S & F in replacementre winding of motor of water cooler of 120 litres storage capacity with suitable size copper super enamelled wire complete all as specified and directed. | 100 | 2 | Each |
| 101 | 89 | S & F in replacement rewinding of motor of water cooler of 80 litres storage capacity with suitable size copper super enamelled wire complete all as specified and directed. | 101 | 2 | Each |
| 102 | 90 | S & F in reapir float valve with copper ball and brass plunger, suitable for 15 mm nominal bore pipe to withstand supply line pressure complete all as specified and directed. | 102 | 3 | Each |
| 103 | 91 | S & F in reapir PVC connection with brass flare nuts internally threaded, 600mm long suitable for 15 mm nominal bore pipe complete all as specified and directed. | 103 | 5 | Each |
| 104 | 92 | S & F in reapir renewal of main cord cable PVC insulated 40/0076, 3 core multistranded copper cable 230 Volts grade, complete all as specdified and directed.\n | 104 | 5 | Each |
| 105 | 93 | S & F in reapir compressor unit of water cooler having cooling capacity 80 litres per hour of Kriloskar make all as specified and directed. Make- Tecunseh | 105 | 2 | Each |
| 106 | 94 | S & F in reapir compressor unit of water cooler having cooling capacity 60 litres per hour of Kriloskar make all as specified and directed. \n | 106 | 1 | Each |
| 107 | 95 | S & F in replacement fan motor of water cooler having cooling capactiy 40 litres per hour of Kriloskar make, complete all as specified and directed. | 107 | 2 | Each |
| 108 | 96 | S & F in replacement fan motor of water cooler having cooling capacity 60 Litres per hour of Kirloskar make complete all as specified and directed. | 108 | 2 | Each |
| 109 | 97 | S & F in replacement air coil condensor for water cooler having cooling capaicty 60/80 Liters per hour of make-Kirloskar, complete all as specified and directed. | 109 | 2 | Each |
| 110 | 98 | S & F in replacement push cock cast bronze alloy screwed down extenally suitable for 15mm nominal bore pipe complete all as specified and directed. | 110 | 6 | Each |
| 111 | 99 | M & L for repair of body of water coolers of any make / capacity by welding MS sheet not less than 1.6 mm thick to match with existing after removing old rusted/unserviceable portion inclduing replacement of old nuts, bolts screws, hinges of top cover and providing thermal insulating material such as thermocol etc as per site requirementcomplete all as specified and directed. | 111 | 2 | Each |
| 112 | 100 | M & L for denting, putty filling, burning out old paint and applying spray painting with two coats of synthetic enamelled paint after preparation of surfaces of water cooler 120 / 80 ltrs capacity complete all as specified and directed | 112 | 3 | Each |
| 113 | 101 | M & L for over hauling of desert cooler of any make and any size including replacement of worn out parished copper conductor wiring of required size,PVC rubber pads for fans motor,PVC water distributor pipe and its fittings like bends,Tee, oiling and greasing the lower motor (exhaust fan) and water lifting pump (Tulu Pump) including testing complete all as specified and directed. | 113 | 30 | Each |
| 114 | 102 | S & F in replacement selector switch single phase, AC 230 Volts, 6 Amps complete all as specified and directed. | 114 | 15 | Each |
| 115 | 103 | S & F in replacement capacitor 4 mfd suitable for desert cooler of any make and size complete all as specified and directed. | 115 | 20 | Each |
| 116 | 104 | S & F in replacement wood wool pad (set of three, weight not less than 200 gram of each pad of size 18\" x 22\") for desert cooler of any size and capacity, complete all as specified and directed. | 116 | 30 | Each |
| 117 | 105 | M & L for preparing old steel surfaces of desert cooler (internally and exteranally) and applying two coats of synthetic enamel paint (water proof) with sprayer complete all as specified and directed | 117 | 5 | Each |
| 118 | 106 | S & F in replacement main cord cable PVC insulated 23/0076, 3 core multistranded copper conductor suitable for 1100 Volts grade, complete all as specified and directed. | 118 | 12 | RM |
| 119 | 107 | S & F in replacement PVC front grill of desert cooler to suit the existing opening and as per existing size including minor fittings and connection to selector switch etc complete all as speified and directed | 119 | 4 | Each |
| 120 | 108 | S & F in replacement desert cooler fan motor 230 Volts, 50Hz, three speed, ISI marked & BIS approved including fan blade complete all as specified and directed | 120 | 10 | Each |
| 121 | 109 | S & F in replacement desert cooler water lifting pump 230 Volts 50 Hz, complete all as specified and directed. | 121 | 20 | Each |
| 122 | 110 | M & L for repairing and overhauling of voltage stabliser of any make and of capaicty 0.50 KVA to 1 KVA in and including electronic circuit, condensor, resistance diodes, transistor integrated chips, transformer, controlling relays, indicating lamp etc as required to bring the machine in a perfect working condition for functioning on load complete all as specified and directed | 122 | 2 | Each |
| 123 | 111 | ~Ditto~ all as per Srl item No. 110 above but voltage stablisers of capacity 2 KVA to 3 KVA. | 123 | 2 | Each |
| 124 | 112 | ~Ditto~ all as per Srl item No. 110 above but voltage stablisers of capacity 4 KVA to 5 KVA. | 124 | 3 | Each |
| 125 | 113 | M & L for in reapir rewinding of transformer coils of voltage stablizer of capacity 0.5 KVA to \n1 KVA complete all as specified and directed. | 125 | 3 | Each |
| 126 | 114 | M & L for in reapir rewinding of transformer coils of voltage stablizer of capacity 2 KVA to 3 KVA complete all as specified and directed. | 126 | 3 | Each |
| 127 | 115 | M & L for in reapir rewinding of transformer coils of voltage stablizer of capacity 4 KVA to 5 KVA complete all as specified and directed. | 127 | 3 | Each |
| 128 | 116 | S & F in reapir Volt meter 50 mm dia, calibaration 0-300 Volts AC complete all as specified and directed. | 128 | 2 | Each |
| 129 | 117 | Taking down ceiling fans of any sweep and any make from fan hooks by disconnecting electric connection, opening up for examination, replacing of defective/ unserviceable parts, cleaning externally and internally, providing fresh oil and grease as required, re-assembling and re-hanging in original location, cleaning & re-fixing of blades, making electric connections and testing etc complete all as specified and directed.\nNote : The rates are included for cutting & using of flexible wire, insulated tape, grease and oil etc | 129 | 550 | Each |
| 130 | 118 | M & L for dismantling of ceiling fan of 1200 mm sweep, cutting of existing worn out winding, cleaning the slots and rewinding with super enameled copper wire of existing guage, varnishing and ball bearing/bush with greasing, re-assembling and testing for RPM complete all as specified and directed. | 130 | 230 | Each |
| 131 | 119 | M & L for dismantling of ceiling fan of 1400 mm sweep, cutting of existing worn out winding, cleaning the slots and rewinding with super enameled copper wire of existing guage, varnishing,ball bearing/bush with greasing re-assembling and testing for RPM complete all as specified and directed. | 131 | 40 | Each |
| 132 | 120 | M & L for preparing old painted surfaces of ceiling fan of any make & sweep including blades and applying a coat of synthetic enamel paint (white) with spray machine and re-writing MES number with black paint complete all as specified and directed. | 132 | 400 | Each |
| 133 | 121 | M & L for preparing old painted surfaces of exhaust fan of any size & make including blades and applying a coat of synthetic enamel paint (smoke grey) with spray machine and re-writing MES number with black paint complete all as specified and directed. | 133 | 10 | Each |
| 134 | 122 | S & F in reapir ceiling fan regulator 240 Volts, resistance type, suitable for 1200 /1400 mm sweep including making connections complete all as specified and directed. | 134 | 5 | Each |
| 135 | 123 | Taking down exhaust fan of any size & make from wall by disconnecting electric connections, opening up for examination and replacing defective/unserviceable parts, cleaning, re-assembling and re-fixing in the same location after testing etc complete all as specified and directed.\nNote:- : The rates are included for cutting & using of flexible wire, insulated tape, grease and oil etc' | 135 | 20 | Each |
| 136 | 124 | M & L for dismantling of exhaust fans of 450 mm sweep, cutting existing burnt coils & cleaning the slots ,rewinding with super enamelled copper wire of existing gauge, varnishing ,ball bearings with greasing , re-assembling & testing complete all as specified and directed. | 136 | 15 | Each |
| 137 | 125 | M & L for dismantling of exhaust fans of 300mm sweep, cutting existing burnt coils & cleaning the slots, rewinding with super enamelled copper wire of existing gauge, varnishing and ball bearing of existing sizes, , re-assembling & testing complete all as specified and directed. | 137 | 30 | Each |
| 138 | 126 | S & F in replacement of geyser base plate assembly complete suitable for 25 litres capacity geyser, complete all as specified and directed. | 138 | 6 | Each |
| 139 | 127 | S & F in replacement of geyser base plate assembly complete suitable for 50 litres capacity geyser, complete all as specified and directed. | 139 | 6 | Each |
| 140 | 128 | S & F in replacement of geyser inner tank, made out of copper, suitable for 25 litres capacity geyser, complete all as specified and directed. | 140 | 4 | Each |
| 141 | 129 | S & F in replacement of geyser inner tank made out of copper suitable for 50 litres capacity geyser, complete all as specified and directed. | 141 | 6 | Each |
| 142 | 130 | S & F in replacement of geyser fusible plug threaded, melting temperature 95 to 100 degree centrigrade, complete all as specified and directed. | 142 | 20 | Each |
| 143 | 131 | S & F in replacement of glass wool of geysers, complete all as specified and directed | 143 | 10 | KG |
| 144 | 132 | S & F in replacement of sheet metal enclosure with chain plug and top with two pin socket of 20 Amps, complete all as specified and directed. | 144 | 1 | Each |
| 145 | 133 | M & L for praparing old painted surfaces of geysers of capacity 25/35 litres and applying one coat of synthetic enamel paint with spray machine complete all as specified and directed. | 145 | 6 | Each \nJob |
| 146 | 134 | M & L for praparing old painted surfaces of geysers of capacity 50 litres and applying one coat of synthetic enamel paint with spray machine complete all as specified and directed. | 146 | 6 | Each \nJob |
| 147 | 135 | S & F in replacement of PVC insulated flexible cable, multi-stranded copper conductor, 4.0 Sqmm, 3 core cable, complete all as specified and directed. | 147 | 60 | RM |
| 148 | 136 | S & F in replacement plug top 15 Amps, 3 pin AC, SP, 230 Volts complete all as specified and directed | 148 | 20 | Each |
| 149 | 137 | S & F in replacement rubber gasket for base plate assembly suitable for geyser of any capacity complete all as specified and directed. | 149 | 10 | Each |
| 150 | 138 | S & F in repair 15 mm bore bib taps, cast copper alloy with cruch or butterfly habdle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. | 150 | 15 | Each |
| 151 | 139 | S & F in repairs indicator lamp red / green in colour, round or ractangular in shape and making connection complete all as specified and directed | 151 | 25 | Each |
| 152 | 140 | S & F in repairs PVC connection for hot water for geyser heavy duty 15mm bore, 450mm long with nuts & washers etc complete all as specified and directed. | 152 | 90 | Each |
| 153 | 141 | S & F in reapir Stop valve 15 mm dia cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe of existing Geyser complete all as specified and directed. | 153 | 20 | Each |
| 154 | 142 | Supply and fix in repair electronic driver for T5 LED fitting 18 W complete all as specified and directed. | 154 | 272 | Each |
| 155 | 143 | S & F in replacement condensor of fan 2.5 mfd of any make but suitable for 1200 /1400 mm sweep fan complete all as specified and directed. | 155 | 200 | Each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy