Corrigendum - Tender For Out Sourcing To The Services For Manning And Operation Of Central Type Ac Plants Hanger No 10 Brahmos Hanger Nos 1 To 4 And Dg Set And Fire Fighting Pump House At Brahmos Hanger And Dg Set Hanger No 10 At Ins Kalinga , Outsourcing For Manning & Operation To Chilled Water Type Ac Plant ( 3X50tr ) Capacity 2 Units Running At A Time And 1 Unit Standby Installed At Hanger No . 10 Ac Plant Manning And Operation By Providing One Refrigerator Mechanic Per Each Shift , 3 Shifts Per Day Round The Clock Including Sundays And Holidays , Comprising Of Lt Panel Board , Substation Incoming And Outgoing Switch Gear 315 Kva , 11Kv , 3 Phase , Lt 433V , 315 Kva Transformer And Capacitor Bank Of 145 Kvar Complete All As Specified In Particular Specifications And Directed By Engineer-In-Charge . , Out Sourcising For Manning & Operation To Central Type Air Cooled Screw Chilled Water Ac Plant Of 3X120 Tr Capacity With Two Units Running At A Time And One Unit Standby Installed At Brahmos Hanger For Manning And Operation By Providing One Refrigerator Mechanic Per Each Shift 3 Shifts Per Day Round The Clock Including Sundays And Holidays All As Specified And Directred By Engineer-In-Charge . , Out Sourcising To Brahmos Hanger Diesel Engine Driven Generating Set Of Capacity 750 Kva , Operating On 415 V , 3 Phase , 50 Hz , 1500 Rpm , Floor Mounted Water Cooled Type With All Accessories Including Exhaust Piping Complete With Silencer , Including Apfc Panel , Lt Panel Board ( Indoor ) For Manning And Operation By Providing One Fitter General Mechanic Per Each Shift For Both Brahmos Dg Set & Fire Fighting Pump House , 3 Shifts Per Day Round The Clock Including Sundays And Holidays All As Directed By Engineer-In-Charge . Make Of Engine: Cummins Make Of Alternator: Stamford . Fire Fighting Pump House: One Working At A Time And One Standby Including Following Pumps And Equipments : ( I ) Jockey Pump Set Consisting Of Induction Motor ( 15 Kw ) , 415 Volts , 2910 Rpm , 3 Phase , 50 Hz And Pump Type 08 / 50126 90 Meter Head ( Ii ) Main Pump Set Consisting Of Induction Motor 55 Kw , 415 Volts , 1468 Rpm , 3 Phase , 50 Hz With Dsn125 / 40 115 Meter Head 150 X 125 Mm Aize With Control Panel Consisting Of 400 Amp . Mccb Bus Bar , Mccb 200 Amp , Eter , Ammeter , Cts , Mcb Tpn 60 Amps & Star Selta Starter And Indicating Lamps . Manual / Auto Operating Knobs - 02 Nos . ( Iii ) Disel Engine Driven Cumins100 Kva Engine Model N 149Sf1 Etws Bhp / Rpm And Pump Type Usm 125 / 40 150 Mtrs Head Size , Automatic Panel Make : Kirloskar , Consist Of Floor Mounted Water Cooled With All Accessories , Including Exhaust Pipe With Silencer Batteries ( 2 Nos ) . ( Iv ) 11 Kv Ht Vcb Breaker-02 ( V ) 1000Kva Transformer 11Kv / 0 . 433 V Out Door Type -01 No . , Outsourcising For Manning & Operation To Diesel Engine Driven Generating Set 320 Kva , 415V , 3 Phase , Neutral , 50Hz , Floor Mounted , Water Cooled With All Accessories Including Exhaust Piping Complete With Sencer , Batteries ( Two Nos ) And Battery Charger With Generating Panel With Engine Make Cummins ( Engine Sl No . 25328307 ) And Alternator Make Stamford H444e1 Alongwith Lt Panel Transformer Indoor Type 11 Kv , 3 Phase , Lt 433 Volts , 500 Kva Complete With Capacitor Banks Lt Panel Complete With Incoming And Outgoing Acb For 500 Kva Transformer And 630 Amps Changeover Switch And Maintaining Daily Log Sheet For Engine Lt And Ht Panels Located At Hanger No . 10 For Manning And Operation By Providing One Fitter General Mechanic Per Each Shift 3 Shifts Per Day Round The Clock Including Sundays And Holidays As Directed By Engineer-In-Charge . Notes For Item Nos . 1 To 4: 1 . Wage Paid By The Contractor To The Persons Employed Shall Not Be Less Than The Minimum Wages Fixed By State / Central Government From Time To Time Whichever Is Higher . The Payment Shall Be Made To The Workers Through A Nationalised Bank And The Bank Statement Of Fair Wages As Per Minimum Labour Wages As Mentioned Above Shall Be Submitted Along With The Rars / Fb For Payments . 2 . The Contractor Shall Be Responsible For The Epf , Esi , Bonus , Safety Etc . And Insurance Of All Trademen Employed By Him As Per Existing Labour Rules / Acts / Regulations . Note For Item Nos . 3 & 4: 1 . Diesel And Engine Oil Will Be Issued Under Sch B Free For Filling . , S&F 3 Tf 46 Contractor , 45 Amps , 2 No+2 Nc Axuilary Contacts Operating On 415 Volts , 50 Hz , Ac Complete Including Taking Down Old One Complete All As Directed By The Engineer-In-Charge . Make: L&T / Siemens / Ge , S&F 400 Amps Open Execution Type Fn ( Tpn ) S-D-F Suitable For Din Fuse Link , 415 Volts , 50 Hz , Ac , Complete Including Taking Down Old One Complete All As Directed By The Engineer-In-Charge . Make: L&T / Siemens / Abb , S&F Electronic Timer Satr To Delta Changer 0-30 Secondss , 415 Volts , 50 Hz Complete All As Directed By The Engineer-In-Charge . Make: Ge / L&T / Seimens , Supply Only Refrigerant Gas ( R22 ) Complete All As Specified And As Directed By The Engineer-In-Charge . Make: Mafran / Floran , Supply Only Gas 134 A Complete All As Specified And As Directed By The Engineer-In-Charge . Make: Mafran / Floran , Supply Only Hfc R-407 A Gas Complete All As Specified And As Directed By The Engineer-In-Charge . Make: Mafran / Floran