Manning And Operation Of The Operation And Maintenance Of 11 Kv Chitra Sub Station At Naval Park And Certain Miscellaneous Works At Naval Park And Amzari Park Under Age E/M No I Of Ge Utility I Visakhapatnam , Out Sourcing For Operation And Maintenance Of Ht/Lt Electrical Sub Stations At Naval Park And The Equipments Installed Round The Clock In 03 Shifts Of 08 Hours Each All As Per The Details Given Below:- Out Sourcing : Minimum One Skilled Electrician And One Mate Electrician Per Shift Of 08 Hours , Note: ( I ) Contractor Is Responsible To Keepintg The Installations Clean And Tidy By Cleanig Daily As Directed . , ( Ii ) The Contractor Is Responsible For The Operation Of All Outdoor/ Indoor Structures Under This Out Sourcing , ( Iii ) The Operator Should Liaise With Command Swimming Pool Sub-Station For Any Major Break Down/ Failure For Early Restoratioin Of Electric Supply Immediately , ( Iv ) Contractor Is Responsible For Arranging Technical Manpower To Rectify The Defects Inside The Sub Stn As Required At Site At The Earliest , ( V ) In Case Any Problem Occurs Which Seems Not Under The Control Of Operator , The Same Shall Be Immediately Intimated To Je I/C Or Age E/M Over Telephone . , ( Vi ) The Contractor Is Also Responsible For The Monitoring And Operation And Maintenance Of Street Lights In The Above Areas . , ( Vii ) Contractor Is Responsible For All Safety Precuations As Per Ie Rules Of Operators Deployed In Ht/Lt Installation Under The Ca , M & L Painting Poles With Two Coats Of Synthetic Enamel Paint Aluminium And Writing Pole No With Synthetic Paint And Fixing Of Two Nos Red Colour Radium Reflected Sticker Around The Pole Including White Wash On Coping All As Directed , S & F Frp Loop In Loop Out Boxes Copatible To Fix Mcb With Mounting Rails , Cable Connector Including Provn Of Suitable Gi Clamps For Fixing To Pole , Pvc Glands Of Hansu Model Hb-14 Or Equivalent In Sintex / Hensal Complete All As Directed , Earthing Complete With Galvanised Steel Earthplate Of Size 60X60cmx6 . 3Mm Thick Electrode And 32X6mm Gi Strip As Earth Lead , Buried Directly In Ground ( Earth Pit Not Less Than 2 . 25M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1 . 5M Below Ground Level , Connected To 32X6mm Earth Strip By Means Of Nuts , Bolts , Check Nuts And Washers Of Gi All As Shown In Electrical Plate No . 5 Of Ssr Part-I , Connected To Earth Test Terminal Point All As Specified Or As Indicated Including Testing On Completion ( Rates Inclusive Of Neccessary Excavation In Any Type Of Soil , Earth Work , Pcc Pit , Ci Cover , Funnel With Watering Pipe , Suitable Size Of Light Grade Gi Protection Pipe For Earth Strip In Ground Etc . All As Required At Site For Complete Earthing ) . , M &L For Cement Concrete Pcc 1:2:4 B1 Using 20 Mm Aggregrate Pole Coping Including Two Coats Of White Wash , Removal Old Coping , And Taking Out The Broken Materils From The Site Etc Complete All As Specified And Directed , M&L For Providing , Injecting And Spraying Of Chemical Emulsion Treatment With Round-Up Chemical From M/S Monsanto For Anti Growth Of Grass And Vegetation Complete All As Directed . , S & F 3 Core 1 . 5 Sq Mm Multi Stranded Copper Conductor , Pvc Insulated Unshethed Cable For Connecting Junction Box To Street Light Fitting Complete All As Directed . , S & F In Repairs Ballast Hpsv/Mh 400 W All As Directed By Engr-In Charge , S & F In Repairs Electornic Igniter For Hpsv/Mh Lamps 400W All As Directed By Engr-In Charge , S & F In Repairs Lamp Mh 400 W Green Colour With Theard All As Directed By Engr-In Charge , S & F In Repairs Lamp Led 9 W /11 W All As Directed By Engr-In Charge , S & F In Repairs Mccb 200 A , 16 Ka 4 Pole , 415V All As Directed By Engr-In Charge , S & F In Repairs Screw Type Holder / B22 Base Holder All As Directed By Engr-In Charge , S & F In Repairs Led Driver Suitable For 45/60 Watt Led Fitting All As Directed By Engr-In Charge , S & F In Repairs Mccb 250 A , 25 Ka 4 Pole , 415V All As Directed By Engr-In Charge , S & F In Repairs Led Driver Suitable For 90/100 Watt Led Fitting All As Directed By Engr-In Charge , S & F In Repairs Led Driver Suitable For 135/150 Watt Led Fitting All As Directed By Engr-In Charge , S & F In Repairs Mccb 400 A , 25 Ka 4 Pole , 415V All As Directed By Engr-In Charge , S & F In Repairs Led Phase Indicating Lamps , All As Directed By Engr-In Charge , S & F In Repairs Mccb 100 A , 16 Ka 4 Pole , 415V All As Directed By Engr-In Charge , S & F In Repairs Mccb 63 A , 16 Ka 4 Pole , 415V All As Directed By Engr-In Charge , S & F In Repairs Digital Ammeter/Voltmeter , 415 V All As Directed By Engr-In Charge , S & F In Repairs Ct , S Suitable To Ammeters To Read /Indicate Up To 1000 Amps All As Directed By Engr-In Charge , S & F In Repairs Digital Timer Switch ( With Battery Backup ) 3P Module 24 Hrs Program , Current Capacity 16A , S & F In Repairs Ballast Hpsv/Mh 250 W All As Direted By Engr-In Charge , S & F In Repairs Lamp Mh 250 W With Theard All As Direted By Engr-In Charge , Supplying , Fixing And Testing Of Post Top Lanthern Lights For Garden And Slope Areas 10W Led Integral Decorative Led Bollard With Opal Acrylic With Ip-65 Protection Of Make Bajaj / Cg / Philips Including Taking Out Old One . , Excavation In Trenches N . Exc1 . 5 Mtr Wide And Not Exc 1 . 5 Mtr Depth And Getting Out Hard/Dense Soil All As Directed , Returning And Filling In Of Excavated Soil Of Any Type Including Spreading , Levelling , Watering And Well Ramming In Layers Not Exceeding 25 Cm Each , Removal Of Surplus Excavated Soil Not Exceeding 50 Mtr And Deposting Where Directed At A Level Not Exceeding 1 . 5 Mtr Above Starting Point , M&L For Sand Cushining/Sand Covering For Underground Cable Protection Complete All As Specified . Note:Punned Thickness Only Will Be Measured And Paid , Supply And Laying Sub -Class B Bricks Of Size 23X11x7 Cm , Supply And Fix Heat Shirnkable Type Lt Straight Joint For Cable3 . 5/4 Core 25 Sqmm To 50 Sqmm Size Make : Raychem/ Birla 3M / Denson , Supply And Fix Heat Shirnkable Type Lt Straight Joint For Cable3 . 5/4 Core 185 Sqmm- 240 Sqmm SizeMake : Raychem/ Birla 3M / Denson , Supply And Fix Heat Shirnkable Type Lt Straight Joint For Cable3 . 5/4 Core 70 Sqmm- 150 Sqmm SizeMake : Raychem/ Birla 3M / Denson , Supplying , Fixing And Testing Of Gate Lights 40W Led Post With Die Cast Aluminium Body And With White Powder Coated Aluminium Reflector And Ip-65 Protection Of Make Cg / Bajaj / Havells / Philips Including Taking Out Old One All As Directed . , Supply And Laying Or Fixing Or Passing Through Pipe Or In Cable Ducts , 11000 Volts Grade Xlpe ( Frls ) Insulated Heavy Duty ( Earthed ) , Screened , Pvc Bedded , Galvanised Steel Strip Or Wire Armoured , Electric Power Cables ( Heavy Duty ) With Aluminium Conductor 185 Sq Mm 3 Core Size Including Dismantling Old One . Make:Nicco/Polycab/Havells/Universal . , Supplying , Fixing And Testing Of Flood Light Die Cast Aluminium Of 200W , 230 Volts ( Maintaing Minmum System Lumen-20000 ) With Ip 66 Including Inbuilt Drive With All Fixing Arrangements With Nuts&Bolts , Clamps , Iron Chanels On Poles Etc With Warranty Certificate Complete All As Specified And Directed By Engineer-In-Charge Including Taking Out Old One Make: Havells Jetairisplusfls200wled757psymltg / Philips/Wipro . , Filtration Of Transformer Oil Of Transformers Installed At Various Locations To Achieve Di-Electric Strength Not Less Than 50 Kv For 1 Minute At 2 . 5Mm Gap As Per Relevant Is With Portable Filtration Plant , Testing Of The Oil For The Di-Electric Strength Complete All As Specified And Directed . , Supply And Topping Up Of Transformer Oil With Di-Electric Strenght Not Less Than 50 Kv I