Replacement Of Technical Area Lighting And Certain Miscellaneous Electrical Works At Non-Technical Area , Site P1 , Supply , Installation , Testing And Commissioning Of Of 63 Kva Rating11kv / 415V , 3 Phase , 50 Hz , Copper Wound , Out Door Type , Transformer , Oil Immersed Onan Cooled , Complete With All Fittings Such As Explosion Vent , Bi Directional Roller , Diagrams And Rating Plate , Magnetic Oil Guage , Oil Temparature Indicator , Winding Temparature Indicator Buchholz Relay Marshalling Box Lifting Lugs Etc . , Complete . , Dismantling Of Existing Rusted Gi Structures , Cross Arms And Other Accessories And Providing New Gi Structrures , Crossarms , 1 Set Do Fuse , 1 Set Ligthening Arrestor , 1 Set Of 11 Kv Ab Switch Etc . , Complete , Providing Chain Link Fencing Around Transformer Yard Up To 1 . 8 Mts Height ( 1 . 5Mts Above Brick Masanory0 ) With A Continuous Brick Masonary Kerb Wall Of 300Mm Above Ground With Suitable Foundation , Plastering And White Wash Of The Same . , Supply And Fixing 1 . 5 X1 . 8 Mts Weld Mesh Gates For Transformer Yard As Per Standard Design . , Supply , Erection , Testing And Commissioning Of Maintenance Free Earth Station With Consisting Of 65Mm Dia , Standard Length ( As Per Equipment Supplier ) Electrode Capsule , Filled With Earth Enhancing Compound , Sealed At Both Ends And Brazed Lead For Connection At One End , Suitable For Direct Installation At Site , At A Depth Of 2 . 5Mtrs . Earth Enhancement Compound Upto A Depth Of 2 . 0Meters Arround The Electrode Capsule . Brick Chamber & Ci Cover Complete . , Supply And Laying Of 25Mm X 5Mm Size Copper Earth Strips Including Excavation And Refilling Of Earth When Laid In Ground And With All Fixing Accessories When Laid In Trench With Necessary Interconnections With Earth Station And Equipments . , Providing And Fixing Of Gi Tape 50Mm X 5Mm From Earth Electrode Directly In Ground As Required , Supply , Laying , Testing And Commissioning Of Following Size 1 . 1Kvgrade Xlpe Insulated Armoured Aluminium Conductor Underground Cable , In Built Up Cable Trench / Already Laid Rcc / Hume Pipe Or On Cable Tray With All Installation Materials . When The Cable Is To Be Laid In Ground , The Same Shall Be Laid At A Depth Of 750Mm Below Ground Level Includingexcavation And Refilling Of Earth After Cables Are Laid , Providing Protection With Sand And Bricks At Sides And Top And Cable Route Markers At Every 15Mtr . Interval And Also At The Turnings . The Cable Shall Conform To Is 1554 . Cost Including All Labour Rates And Overheads & Profits Etc Complete . , 4C X 16 Sqmm In Ground , 4C X 10 Sqmm In Ground , 4C X 6 Sqmm In Ground , Providing Indoor Ordinary End Terminations For The Cable Specified Below With Double Compression Type Brass Gland , Aluminium Lugs Using Crimping Tool , Insulation Tape , Identification Tags , Gland Earthing Connections Etc . , Including End Termination . Cost Including All Labour Rates And Overheads & Profits Etc Complete . , 4C X 16 Sqmm , 4C X 10 Sqmm , 4C X 6 Sqmm , Supply , Installation Testing And Commissioning Of Street Light Fixtures On The Existing Poles With Accessories ( Philips Model No Brp 322 Led 142 Cw Mr Fg S4 Xtfc Lgr Or Equivallent And Suitable Gi Bracket For Fixing Led Light Fixtures Including All Weather Proof Fibre Junction Box For Street Light Fixtures With 4 Way Contactor And 6A Spnmcb With Hardwards , Servicing Of Air Circuit Breakers Of Main Sychronising Panel . , Supply And Installation Of 990 Lts Fuel Ms Tanks With Ms Angle Iron Pedestals And 2 Nos Gatevalves And Calibrated Scale Etc . , Complete All As Per The Direction Of Engineer In Charge . , Supply And Erection Of The Following Size Gi / Cpvc Fuel Line Including Specials . , 32Mm Dia Cpvc Pipe , 40Mm Dia Cpvc Pipe , 32Mm Dia Gi Pipe , Supply And Installation Of 600Mm Dia Axial Fans Including Mounting Arrangements With Civil Works . , Painting Of Approved Enamel Paint For Rolling Shutters , Panels Etc . , , Providing And Fixing Precoated Galvanised Iron Profile Sheets ( Size , Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0 . 50 Mm ( + 0 . 05 % ) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277 , In 240 Mpa Steel Grade , 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns . Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineerin- Charge . The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5 . 5X 55 Mm ) With Epdm Seal , Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces , Excluding The Cost Of Purlins , Rafters And Trusses And Including Cutting To Size And Shape Wherever Required , Removal Of Damaged Pin Insulators , Disc Insulators , Acsr Conductors ( Approximate Quantity Of3 Runs X 1600 Mtrs ) And Clamps Etc . , Complete . , Credit Items Like Damaged Acsr Conductor For The Above S . No . 17 , Credit Items Like Old Transformer , Insulators And Cables Etc , .