Quotation are invited for Fluke 376 Fc - New Delivery Date: 2025/02/28 Delivery To: Electricity - Ndabeni RED1 Plant / PH: 511 0410 Delivery Address: 0000 GENERIC PLANT, CAPE TOWN Closing Date: 2025/02/14 Closing Time: 12:00 PM Description: 3 each x fluke 376 fc - new 1 each x fluke 376 fc - replacement Specification: * QUOTATION CONDITIONS CLAUSE - 2.14.1 & 2.15 Provide, on request by the CCT, any other material that has a bearing on the quotation offer, the supplier#s commercial position (including joint venture agreements), preferencing arrangements, or samples of materials, considered necessary by the CCT for the purpose of the evaluation of the quotation. If the Specifications require the supplier to provide samples/technical data sheets, these shall be provided strictly in accordance with the instructions set out in the Specification. If such samples /technical data sheets are not submitted as required in the bid documents or within any further time stipulated by the CCT in writing, then the bid concerned may be declared non-responsive. # Wherever reference is made to any particular Trade Mark, Name, Patent, Design, Type, Specific Origin or Producer, such reference shall be deemed to be accompanied by the words or equivalent # NB: The Municipal Bidding Document 6.1 (MBD 6.1) is attached, in order to be eligible for preference points bidders are required to submit a duly completed, current dated MBD 6.1 document with supporting documents with each and every RFQ submission, failure to submit will result in zero point allocation. Fluke 376 FC 1000AM Trms Clamp + 1 Flex 18 or equivalent Maximum voltage between any terminal and earth ground 1000 V Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6 Temperature Operating: -10 °C to +50 °C (14 °F to + 122 °F) Storage: -40 °C to +60 °C (-40 °F to + 140 °F) Operating humidity Non condensing ( 10 °C (50 °F)), =90 % RH (at 10 °C to 30 °C (50 °F to 86 °F)), =75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), =45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) Altitude Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) Dimensions 24.9 cm (9.8 in) x 8.5 cm (3.3 in) x 4.5 cm (1.7 in) Weight 395 g (13.9 oz) Jaw opening 34 mm (1.3 in) Flexible current probe diameter 7.5 mm (.29 in) Flexible current probe cable length (head to electronics connector) 1.8 m (70.8 in) Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBL Contact Person: Algernon Clayton 021 444 1885 / Algernon.Clayton@capetown.gov.za * Fluke 376 FC 1000AM Trms Clamp + 1 Flex 18 or equivalent Maximum voltage between any terminal and earth ground 1000 V Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6 Temperature Operating: -10 °C to +50 °C (14 °F to + 122 °F) Storage: -40 °C to +60 °C (-40 °F to + 140 °F) Operating humidity Non condensing ( 10 °C (50 °F)), =90 % RH (at 10 °C to 30 °C (50 °F to 86 °F)), =75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), =45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) Altitude Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) Dimensions 24.9 cm (9.8 in) x 8.5 cm (3.3 in) x 4.5 cm (1.7 in) Weight 395 g (13.9 oz) Jaw opening 34 mm (1.3 in) Flexible current probe diameter 7.5 mm (.29 in) Flexible current probe cable length (head to electronics connector) 1.8 m (70.8 in) Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBL Contact Person: Algernon Clayton 021 444 1885 / Algernon.Clayton@capetown.gov.za Tender Link : http://web1.capetown.gov.za/web1/ProcurementPortal/RFQ/Details/300629